PubMed Health⌕ Search

Biomedical subjects

William D Spotnitz

Publications and source records attributed to William D Spotnitz.

9 recordsLinked to original sources

Therapeutic efficacy and safety of red blood cells treated with a chemical process (S-303) for pathogen inactivation: a Phase III clinical trial in cardiac surgery patients.

BACKGROUND: A randomized, double-blind trial is reported of the clinical efficacy of red blood cells (RBCs) treated for pathogen inactivation with S-303, a synthetic labile alkylating agent. STUDY DESIGN AND METHODS: Patients undergoing complex cardiac surgeries were randomly assigned to receive either S-303-treated (test) or conventional (control) RBC transfusion during surgery and for 6 days thereafter. Efficacy was evaluated by comparing the occurrence of a composite primary endpoint of treatment-related morbidity (myocardial infarction and renal failure) and mortality. RESULTS: Two-hundred twenty-three patients were randomly assigned and 148 patients who received transfusions (74 with S-303-treated RBCs and 74 with control RBCs) were evaluable. The incidence of the primary endpoint was equivalent between the two groups (22 and 21% in the S-303-treated and control RBC groups, respectively). Secondary endpoints, including hemoglobin increment (mean, 1.4 vs. 1.5 g/dL), number of RBC transfusions (mean, 4.4 vs. 3.8 units), and other blood product support, were also comparable. The adverse event profile was similar between groups; however, patients who received S-303 RBCs were significantly more likely to develop constipation and less likely to suffer supraventricular extrasystoles. Four patients (2 test and 2 control) demonstrated positive indirect antiglobulin tests with reactivity for S-303 RBCs at one or more time points before or after transfusion, without evidence of hemolysis. CONCLUSION: S-303-treated and conventional RBCs were equivalent with respect to clinical efficacy and safety in supporting the transfusion needs of cardiac surgery patients. Investigations are under way to ascertain the significance of S-303 RBC antibodies and to prevent their occurrence.

Acridines↗

Fibrin sealant tissue adhesive--review and update.

The field of surgical tissue adhesives is rapidly developing, with multiple products now available. Fibrin sealant, the first widely available tissue adhesive, continues to be used in traditional as well as in new and creative ways. The product is now fully mature as a hemostatic agent in cardiac, liver, and spleen surgery. It is also useful as a sealant in a variety of clinical applications, including procedures such as colonic anastomosis, as well as in seroma prevention following soft tissue dissection. Newer uses such as reduced suture vascular and intestinal anastomosis, fistula closure, surgery in patients with hemophilia, and laparoscopic/endoscopic procedures are being studied in both laboratory and clinical settings. The most recent additions to the capabilities of fibrin sealant include the use of this tissue adhesive as a slow-release drug delivery system and as a substrate for cellular growth and tissue engineering. This article will review the basis of fibrin sealant effectiveness and will also cover the recent developments in the rapidly evolving employment of this material.

Algorithms↗

Absorbable cyanoacrylate as a vascular hemostatic sealant: a preliminary trial.

No absorbable cyanoacrylate tissue adhesive for safe internal surgical use is available. This prospective multicenter preliminary study was designed to evaluate the safety and effectiveness of an investigational absorbable cyanoacrylate (IAC) as an adjunct to hemostasis in arteriovenous shunt (AVS) procedures for dialysis access. Consenting adults (10) underwent placement of expanded polytetrafluoroethylene (ePTFE) upper extremity vascular grafts for AVS access using continuous 5-0 or 6-0 polypropylene after heparinization (> or =3000 units i.v.). Arterial anastomoses were evaluated after sealing with IAC followed by 120 seconds of polymerization time. After vascular clamp removal, the mean time to hemostasis was 9.1 +/- 28.8 seconds. Additionally, 90 per cent (9/10) and 100 per cent (10/10) achieved hemostasis by 1 and 5 minutes, respectively. No patients required further adjunctive hemostatic measures. Adverse event safety data analysis through 12 weeks revealed occlusion of graft or vessel in four patients and graft thrombosis in one patient, all thought unrelated to sealant use. Other unrelated adverse events (bleeding, death, deep venous thrombosis, edema, erythema, hematoma, infection, and rash) occurred in single patients. Thus, IAC could be a useful sealant for vascular procedures with a potentially satisfactory safety profile. Larger, randomized, multicenter, prospective trials to further evaluate the use of this material are indicated and appropriate.

Adult↗

Left ventricular dysfunction after pericardiectomy for constrictive pericarditis.

A 56-year-old man was admitted to our hospital with a diagnosis of suspected constrictive pericarditis. After the diagnosis was confirmed by cardiac catheterization, an elective pericardiectomy was performed without complication. Four days after surgery dyspnea developed in the patient, and he was found to have an acute decrease in left ventricular ejection fraction (LVEF) by echocardiography. The patient's symptoms and the LVEF improved over time and returned to normal 4 weeks after surgery. Transient hemodynamic dysfunction of the left ventricle has previously been reported after pericardiectomy or pericardiocentesis; however, we know of no reports in the literature that confirm an acute reduction in LVEF by echocardiography after pericardiectomy for constrictive pericarditis.

Echocardiography↗

Fibrin sealant improves hemostasis in peripheral vascular surgery: a randomized prospective trial.

OBJECTIVE: To evaluate the efficacy and safety of an investigational fibrin sealant (FS) in a randomized prospective, partially blinded, controlled, multicenter trial. SUMMARY BACKGROUND DATA: Upper extremity vascular access surgery using polytetrafluorethylene (PTFE) graft placement for dialysis was chosen as a reproducible, clinically relevant model for evaluating the usefulness of FS. The FS consisted of pooled human fibrinogen (60 mg/mL) and thrombin (500 NIH U/mL). Time to hemostasis was measured, and adverse events were monitored. METHODS: Consenting adult patients (n = 48) undergoing placement of a standard PTFE graft were randomized in a 2:1:1 ratio to the treatment group using FS (ZLB Bioplasma AG, Bern, Switzerland), oxidized regenerated cellulose (Surgicel, Johnson & Johnson, New Brunswick, NJ), or pressure. Patients received heparin (3,000 IU IVP) before placement of vascular clamps. If the treatment was FS, clamps were left in place for 120 seconds after the application of study material to permit polymerization. If treatment was Surgicel, clamps were left in place until the agent had been applied according to manufacturer's instructions. If the treatment was pressure, clamps were released as soon as the investigator was ready to apply compression. Immediately after release of the last clamp, the arterial and venous suture lines were evaluated for bleeding. The time to hemostasis at both the venous and arterial sites was recorded. RESULTS: Significant (P < or =.005) reduction in time to hemostasis was achieved in the FS group. Thirteen (54.2%) patients randomized to FS experienced immediate hemostasis at both suture lines following clamp removal compared to no patients using Surgicel or pressure. Only one patient (7.1%) in the Surgicel group and no patients in the pressure group experienced hemostasis at 120 seconds from clamp removal, compared to 13 (54.2%) patients for FS. Adverse events were comparable in all groups. There were no seroconversions. CONCLUSIONS: FS achieved more rapid hemostasis than traditional techniques in this peripheral vascular procedure. FS use appeared to be safe for this procedure.

Aged↗

Experience improves successful use of fibrin sealant in total knee arthroplasty: implications for surgical education.

This study evaluating fibrin sealant application in total knee arthroplasty (TKA) found significant differences in the decline in adjusted hemoglobin loss at 48 hours postoperatively in the treatment group (FS) relative to the control group (C) when the groups were segregated into early and late subgroups. The decline between the late C, 3.53 +/- 0.22 g/dL, and the late FS, 3.01 +/- 0.20 g/dL, was 0.52 g/dL (p = 0.04). The decline between the early C, 3.51 +/- 0.21 g/dL, and the early FS, 3.25 +/- 0.22 g/dL, was 0.26 g/dL (p = 0.34). This study demonstrates the importance of experience and education in successful application of tissue adhesives.

Aged↗

Fibrin sealant reduces perioperative blood loss in total hip replacement.

Patients (n = 81) undergoing total hip replacement (THR) were randomized to receive either standard of care plus fibrin sealant (FS) (10 mL total) or standard of care alone to evaluate the efficacy of FS for reducing blood loss in THR. Considering the 81 intent-to-treat patients, adjusted perioperative blood loss was reduced significantly in the FS group, by 197 mL [95% CI: 45 mL, 319 mL] or 23.5% [95% CI: 5.4%, 38.1%] (p = 0.014). When protocol violators were eliminated, leaving 73 patients, the adjusted FS group perioperative bleeding was reduced by 221 mL [95% CI: 63 mL, 351 mL] or 27.1% [95% CI: 7.6%, 42.5%] (p = 0.0098).

Adult↗

Fibrin sealant facilitates hemostasis in arteriovenous polytetrafluoroethylene grafts for renal dialysis access.

A prospective randomized study was performed to evaluate the efficacy of fibrin sealant (FS) in patients undergoing upper-extremity polytetrafluoroethylene (PTFE) graft placement for dialysis. This procedure appears to be a reproducible and clinically relevant model for evaluating FS in vascular surgery. Consenting adult patients (n = 28) undergoing placement of a PTFE graft (6 mm) were randomized to either the treatment group using FS (Hemaseel APR, Haemacure Corp., Sarasota, FL) or control comparator groups (four) of bovine thrombin (T) (Thrombogen, GenTrac Inc., Middleton, WI), pressure (P), bovine thrombin (Thrombogen, GenTrac Inc.) -soaked cellulose sponges (TG) (Gelfoam, Upjohn Co., Kalamazoo, MI), or oxidized regenerated cellulose (S) (Surgicel, Johnson & Johnson, New Brunswick, NJ). All patients received heparin (3000 IU intravenous push) before placement of vascular clamps. The mean time to hemostasis was 29.3 seconds for FS, 147.4 seconds for T, 872.2 seconds for P, 346 seconds for TG, and 1044.5 seconds for S. There were no significant adverse events. FS appeared to be a superior hemostatic agent in these vascular procedures. No complications from FS were noted.

Arteriovenous Shunt, Surgical↗