PubMed Health⌕ Search

Biomedical subjects

William G Telford

Publications and source records attributed to William G Telford.

At least 19 recordsLinked to original sources

Side population analysis using a violet-excited cell-permeable DNA binding dye.

Hoechst 33342 side population (SP) analysis is a common method for identifying stem cells in mammalian hematopoietic and nonhematopoietic tissues. Although widely employed for stem cell analysis, this method requires an ultraviolet (UV) laser to excite Hoechst 33342. Flow cytometers equipped with UV sources are not common because of the cost of both the laser and optics that can transmit light UV light. Violet laser sources are inexpensive and are now common fixtures on flow cytometers, but have been previously shown to provide insufficient Hoechst dye excitation for consistent resolution of SP cells. One solution to this problem is to identify additional fluorescent substrates with the same pump specificity as Hoechst 33342, but with better violet excitation characteristics. DyeCycle Violet reagent has emission characteristics similar to those of Hoechst 33342, but with a longer wavelength excitation maxima (369 nm). When this dye is loaded into hematopoietic cells, a sharply resolved side population was also observed, similar in appearance to that seen with Hoechst 33342. Unlike Hoechst SP, DCV SP was similar in appearance with both violet and UV excitation. DCV SP could be inhibited fumitremorgin C, and showed the same membrane pump specificity as Hoechst 33342. Simultaneous immunophenotyping with stem cell markers in mouse bone marrow demonstrated that DCV SP was restricted to the stem cell lineage(-) Sca-1(+) c-kit(+) cells population, as is Hoechst SP. Pending confirmation by functional analysis of DCV SP cells, these results suggest that DCV efflux identified approximately the same stem cell population as did Hoechst 33342 efflux. Substituting DCV for Hoechst 33342 in the SP technique may, therefore, allow side population analysis on flow cytometers with violet lasers.

Animals↗

The tyrosine kinase inhibitor genistein blocks HIV-1 infection in primary human macrophages.

Binding of HIV-1 envelope glycoprotein (Env) to its cellular receptors elicits a variety of signaling events, including the activation of select tyrosine kinases. To evaluate the potential role of such signaling, we examined the effects of the tyrosine kinase inhibitor, genistein, on HIV-1 entry and infection of human macrophages using a variety of assays. Without altering cell viability, cell surface expression of CD4 and CCR5 or their abilities to interact with Env, genistein inhibited infection of macrophages by reporter gene-encoding, beta-lactamase containing, or wild type virions, as well as Env-mediated cell-fusion. The observation that genistein blocked virus infection if applied before, during or immediately after the infection period, but not 24h later; coupled with a more pronounced inhibition of infection in the reporter gene assays as compared to both beta-lactamase and p24 particle entry assays, imply that genistein exerts its inhibitory effects on both entry and early post-entry steps. These findings suggest that other exploitable targets, or steps, of the HIV-1 infection process may exist and could serve as additional opportunities for the development of new therapeutics.

Cells, Cultured↗

The minimal instrumentation requirements for Hoechst side population analysis: stem cell analysis on low-cost flow cytometry platforms.

The Hoechst side population (SP) technique is a critical method of identifying stem cells and early progenitors in rodent, nonhuman primate, and human hematopoietic and nonhematopoietic tissues. In this technique, the cell-permeable DNA-binding dye Hoechst 33342 is loaded into the cell population of interest; stem cells and early progenitors subsequently pump this dye out via an ATP-binding cassette membrane pump-dependent mechanism, resulting in a low-fluorescence "tail" (the SP) when the cells are analyzed by flow cytometry. This population contains stem cells and early progenitors. One significant drawback of this method is the requirement of an UV laser to excite the Hoechst 33342. Unfortunately, flow cytometers equipped with UV sources are expensive to own and operate and are not readily available to many laboratories or institutions. In the interests of designing a less expensive flow cytometric system for stem cell analysis, we determined the minimum UV excitation and instrumentation requirements for measuring Hoechst SP. Less than 3 mW of UV laser output was required for adequate resolution of Hoechst SP on two cuvette-based flow cytometers, one of which was a simple, inexpensive benchtop analyzer (the Quanta Analyzer; NPE Systems). Furthermore, Hoechst SP could also be adequately resolved on this epifluorescence-based cytometer platform using two nonlaser UV sources, a mercury arc lamp with a UV bandpass filter and a UV-emitting light-emitting diode. These results suggest that an economical flow cytometric system can be designed that is capable of resolving Hoechst SP, with a cost far lower than most UV laser-equipped commercial systems. An inexpensive system of this type would make Hoechst SP analysis available to a much broader group of stem cell investigators.

Animals↗

Dysregulation of IL-15-mediated T-cell homeostasis in TGF-beta dominant-negative receptor transgenic mice.

T-cell subpopulations, defined by their expression of CD4, CD8, naive, and memory cell-surface markers, occupy distinct homeostatic compartments that are regulated primarily by cytokines. CD8+ memory T cells, as defined by CD44(hi) surface expression, are dependent on IL-15 as a positive regulator of their homeostatic maintenance. Manipulation of IL-15 signaling through gene aberration, overexpression, or receptor alterations has been shown to dramatically affect T-cell homeostasis, with overexpression leading to fatal leukemia. Here we show that TGF-beta is the critical negative regulator of murine CD8+ memory T-cell homeostasis with direct opposition to the positive effects of IL-15. This negative regulation is mediated, at least in part, by the ability of TGF-beta to modulate expression of the beta-chain of the IL-15 receptor, thus establishing a central axis between these 2 cytokines for homeostatic control of CD8+ memory T-cell populations. These data establish TGF-beta as a critical and dominant tumor-suppressor pathway opposing IL-15-mediated CD8+ T-cell expansion and potential malignant transformation.

Adoptive Transfer↗

Histone deacetylase inhibitor pharmacodynamic analysis by multiparameter flow cytometry.

Histone deacetylase (HDAC) inhibitors are a promising new class of anticancer drug. The aim of this study was to develop a versatile and sensitive technique for the pharmacodynamic (PD) assessment of HDAC inhibitor activity as monotherapy and in combination therapy. A multiparameter flow cytometric assay was developed initially in healthy donor lymphocytes and leukemia cell lines, and then tested in peripheral blood of solid tumor patients and in bone marrow aspirates of leukemia patients on phase I trials of the HDAC inhibitor MS-275. A technique was developed that allows highly sensitive single parameter determination of HDAC inhibitor activity in as little as 50 microl of whole blood. Multiparameter analysis enabled correlation on a single cell basis of protein acetylation with biologically relevant markers including cell lineage antigens, an apoptosis marker, and PD markers of other anti-cancer agents. The level of protein acetylation can be readily detected and quantified in peripheral blood or in bone marrow aspirates by flow cytometric analysis. The technique described has significant advantages for the PD assessment of HDAC inhibitors as monotherapy and as a component of combination therapy trials.

Antineoplastic Agents↗

Discrimination of the Hoechst side population in mouse bone marrow with violet and near-ultraviolet laser diodes.

BACKGROUND: Discrimination of stem cells with flow cytometric analysis of Hoechst 33342 efflux by the ABCG2 transporter (termed the Hoechst side population, or SP technique) is a valuable methodology for identifying bone marrow progenitors enriched with stem cells. Unfortunately, it requires a ultraviolet (UV) laser source, usually necessitating an expensive and maintenance-intensive argon- or krypton-ion gas laser on a large-scale cell sorter. In this study, we evaluated the ability of recently available violet and near-UV laser diodes to discriminate Hoechst SP on smaller cuvette-based flow cytometers. METHODS: Violet laser diodes (emitting at 408 and 401 nm) and a near-UV laser diode (emitting at 370 nm) were mounted on a BD Biosciences LSR II and evaluated for their ability to discriminate Hoechst SP in murine bone marrow. RESULTS: The violet laser diodes discriminated the Hoechst SP, but with poorer resolution than with the standard UV gas laser on a large-scale cell sorter. The near-UV laser diode, in contrast, gave excellent Hoechst SP resolution. CONCLUSIONS: These evaluations indicated that near-UV laser diodes give excellent Hoechst SP resolution on cuvette-based instruments. As the next generation of cell sorters integrate cuvette-based cell interrogation into conventional jet-in-air cell separation, these laser sources should become applicable for analysis and physical separation of Hoechst SP cells.

Animals↗

Analysis of UV-excited fluorochromes by flow cytometry using near-ultraviolet laser diodes.

INTRODUCTION: Violet laser diodes have become common and reliable laser sources for benchtop flow cytometers. While these lasers are very useful for a variety of violet and some ultraviolet-excited fluorochromes (e.g., DAPI), they do not efficiently excite most UV-stimulated probes. In this study, the next generation of InGaN near-UV laser diodes (NUVLDs) emitting in the 370-375-nm range have been evaluated as laser sources for cuvette-based flow cytometers. METHODS: Several NUVLDs, ranging in wavelength from 370 to 374 nm and in power level from 1.5 to 10 mW, were mounted on a BD Biosciences LSR II and evaluated for their ability to excite cells labeled with the UV DNA binding dye DAPI, several UV phenotyping fluorochromes (including Alexa Fluor 350, Marina Blue, and quantum dots), and the fluorescent calcium chelator indo-1. RESULTS: NUVLDs at the 8-10-mW power range gave detection sensitivity levels comparable to more powerful solid-state and ion laser sources, using low-fluorescence microsphere beads as measurement standards. NUVLDs at all tested power levels allowed extremely high-resolution DAPI cell cycle analysis, and sources in the 8-10-mW power range excited Alexa Fluor 350, Marina Blue, and a variety of quantum dots at virtually the same signal-to-noise ratios as more powerful UV sources. CONCLUSIONS: These evaluations indicate that near-UV laser diodes installed on a cuvette-based flow cytometer performed nearly as well as more powerful solid-state UV lasers on the same instrumentation, and comparably to more powerful ion lasers on a jet-in-air system, and. Despite their limited power, integration of these small and inexpensive lasers into benchtop flow cytometers should allow the use of flow cytometric applications requiring UV excitation on a wide variety of instruments.

Animals↗

Multiparametric analysis of apoptosis by flow and image cytometry.

Flow cytometric assays for apoptosis are now in widespread use. The multiparametric nature of flow cytometry allows multiple assays for several apoptotic characteristics to be combined in a single sample, providing a powerful tool for elucidating the complex progression of apoptotic death in a variety of cell types. This chapter describes one such assay, allowing simultaneous analysis of caspase activation, annexin V binding to "flipped" phosphatidylserine residues and membrane permeability to DNA binding dyes. This multidimensional approach to analyzing apoptosis provides far more information than single-parameter assays that provide only an ambiguous "percent apoptotic" result, given that multiple early, intermediate, and late apoptotic stages can be visualized simultaneously. This multiparametric approach is also amenable to a variety of flow cytometric instrumentation, both old and new.

Animals↗

Telomere length measurement by fluorescence in situ hybridization and flow cytometry.

Telomere length is an important measure of cellular differentiation and progression to senescence. Flow cytometric assays for measuring telomere length have become an important adjunct to more laborious Southern blotting methods; telomere length can be estimated with considerable accuracy in small numbers of individual cells by flow cytometry, and can be measured in cell population subsets with simultaneous fluorescent immunophenotyping. In this chapter, we describe the standard flow cytometric assay for measuring telomere length, including the incorporation of fluorochrome-conjugated antibody immunolabeling for measurement in cell subsets.

CD4 Antigens↗

Small lasers in flow cytometry.

Laser technology has made tremendous advances in recent years, particularly in the area of diode and diode-pumped solid state sources. Flow cytometry has been a direct beneficiary of these advances, as these small, low-maintenance, inexpensive lasers with reasonable power outputs are integrated into flow cytometers. In this chapter we review the contribution and potential of solid-state lasers to flow cytometry, and show several examples of these novel sources integrated into production flow cytometers. Technical details and critical parameters for successful application of these lasers for biomedical analysis are reviewed.

Flow Cytometry↗

Proliferation kinetics of subpopulations of human marrow cells determined by quantifying in vivo incorporation of [2H2]-glucose into DNA of S-phase cells.

This report investigated in vivo turnover kinetics of marrow hematopoietic progenitors and precursors using a recently developed stable isotope-mass spectrometric technique (SIMST). Human subjects were administered a 2-day infusion of 6,6-[2H2]-glucose, a nontoxic stable isotope-labeled form of glucose, which becomes incorporated into DNA of all S-phase cells. The percent [2H2]-glucose incorporated into DNA in the form of [2H2]-deoxyadenosine (%[2H2]-dA enrichment) was determined by gas chromatography-mass spectrometry. The rate constant of replacement of unlabeled by labeled DNA strands (labeling kinetics) was used to calculate population turnover kinetics of CD34+ cells, CD133+ cells, and CD133-CD34+ cells. The observed mean replacement half-life (t1/2) was 2.6 days for CD34+ cells, 2.5 days for CD133-CD34+ cells, and 6.2 days for CD133+ cells. Results from the estimated rate constant of replacement of labeled by unlabeled DNA (delabeling kinetics) also demonstrated slower turnover rates for CD133+ cells than for CD133-CD34+ cells. Although there was a relatively rapid initial decrease in the %[2H2]-dA enrichment, low levels of labeled DNA persisted in CD34+ cells for at least 4 weeks. The results indicate the presence of subpopulations of CD34+ cells with relatively rapid turnover rates and subpopulations with a slower t1/2 of 28 days. Results also demonstrate that in vivo [2H2]-glucose-SIMST is sensitive enough to detect differences in turnover kinetics between erythroid and megakaryocyte lineage cells. These studies are the first to demonstrate the use of in vivo [2H2]-glucose-SIMST to measure in vivo turnover kinetics of subpopulations of CD34+ cells and precursors in healthy human subjects.

AC133 Antigen↗

Analysis of violet-excited fluorochromes by flow cytometry using a violet laser diode.

BACKGROUND: Low power violet laser diodes (VLDs) have been evaluated as potential replacements for water-cooled argon-ion and krypton-ion ultraviolet and violet lasers for DNA content analysis using the Hoechst dyes and 4,6-diamidino-2-phenylindole (Shapiro HMN, Perlmutter NG: Cytometry 44:133-136, 2001). In this study, we used a VLD to excite a variety of violet-excited fluorescent molecules important in biomedical analysis, including the fluorochromes Cascade Blue and Pacific Blue, the expressible fluorescent protein cyan fluorescent protein (CFP), and the fluorogenic alkaline phosphatase (AP) substrate 2-(5'-chloro-2'-phosphoryloxyphenyl)-6-chloro-4-(3H)-quinazoline (ELF-97; for endogenous AP detection and cell surface labeling with AP-conjugated antibodies). METHODS: Comparisons were made between VLD excitation and a krypton-ion laser emitting at 407 nm (both at higher power levels and with the beam attenuated at levels approximating the VLD) on the same FACSVantage SE stream-in-air flow cytometer. We evaluated a Power Technology 408-nm VLD (30 mW) equipped with circularization optics (18 mW maximum output, set to 15 mW) and a Coherent I-302C krypton-ion laser emitting at power levels ranging from 15 to 75 mW. RESULTS: Cascade Blue, Pacific Blue, and CFP showed comparable signal-to-noise ratios and levels of sensitivity with VLD excitation versus the krypton-ion laser at high and VLD-matched power outputs. Multicolor fluorescent protein analysis with 488-nm excitation of green fluorescent protein and DsRed and VLD excitation of CFP was therefore feasible and was demonstrated. Similar levels of excitation efficiency between krypton-ion and VLD sources also were observed for ELF-97 detection. CONCLUSIONS: These evaluations confirmed that VLDs may be cost- and maintenance-effective replacements for water-cooled gas lasers for applications requiring violet excitation in addition to DNA binding dyes.

Alkaline Phosphatase↗

Tamoxifen and the farnesyl transferase inhibitor FTI-277 synergize to inhibit growth in estrogen receptor-positive breast tumor cell lines.

Farnesyl transferase inhibitors (FTIs) serve to specifically inhibit farnesyl isoprenoid lipid modification of proteins. Although originally developed as anti-Ras oncoprotein drugs, it now appears that these compounds function independently of Ras. FTIs have been shown to inhibit transformation by a variety of mechanisms, including apoptosis involving cytochrome c release from mitochondria. Tamoxifen exhibits both anti-estrogenic and estrogenic properties and is widely used as an estrogen antagonist for the treatment of estrogen receptor (ER) positive human breast tumors. Tamoxifen can induce ER-dependent apoptosis in human breast tumor cells by a mechanism involving the Bcl2/mitochondrial arm of the apoptotic machinery. Since tamoxifen and FTIs may stimulate distinct components of the mitochondrial-based apoptotic machinery, we reasoned that their effects might be synergistic. Here we show that anti-estrogens and an FTI (FTI-277) synergize to inhibit cell growth and enhance cell death in ER positive, human breast tumor cell lines. However, the drugs exhibited only additive effects on an ER negative cell line. Analysis of treated ER positive T-47D cells demonstrated that a synergistic increase in apoptosis was induced, as measured by increased caspase 3 activity. Thus, tamoxifen and FTIs may synergize to promote apoptotic cell death in ER positive human breast tumor cells.

Antineoplastic Agents↗

Side population keratinocytes resembling bone marrow side population stem cells are distinct from label-retaining keratinocyte stem cells.

Very primitive hematopoietic stem cells have been identified as side population cells based on their ability to efflux a fluorescent vital dye, Hoechst 33342. In this study we show that keratinocytes with the same side population phenotype are also present in the human epidermis. Although side population keratinocytes have the same dye-effluxing phenotype as bone marrow side population cells and can be blocked by verapamil, they do not express increased levels of the ABCG2 transporter that is believed to be responsible for the bone marrow side population phenotype. Because bone marrow side population cells have stem cell characteristics, we sought to determine if side population keratinocytes represent a keratinocyte stem cell population by comparing side population keratinocytes with a traditional keratinocyte stem cell candidate, label-retaining keratinocytes. Flow cytometric analyses demonstrated that side population keratinocytes have a different cell surface phenotype (low beta1 integrin and low alpha6 integrin expression) than label-retaining keratinocytes and represent a unique population of keratinocytes distinctly different from the traditional keratinocyte stem cell candidate. Future in vivo studies will be required to analyze the function of side population keratinocytes in epidermal homeostasis and to determine if side population keratinocytes have characteristics of keratinocyte stem cells.

ATP Binding Cassette Transporter, Subfamily B, Mem↗

Quantitative comparison of long-wavelength Alexa Fluor dyes to Cy dyes: fluorescence of the dyes and their bioconjugates.

Amine-reactive N-hydroxysuccinimidyl esters of Alexa Fluor fluorescent dyes with principal absorption maxima at about 555 nm, 633 nm, 647 nm, 660 nm, 680 nm, 700 nm, and 750 nm were conjugated to antibodies and other selected proteins. These conjugates were compared with spectrally similar protein conjugates of the Cy3, Cy5, Cy5.5, Cy7, DY-630, DY-635, DY-680, and Atto 565 dyes. As N-hydroxysuccinimidyl ester dyes, the Alexa Fluor 555 dye was similar to the Cy3 dye, and the Alexa Fluor 647 dye was similar to the Cy5 dye with respect to absorption maxima, emission maxima, Stokes shifts, and extinction coefficients. However, both Alexa Fluor dyes were significantly more resistant to photobleaching than were their Cy dye counterparts. Absorption spectra of protein conjugates prepared from these dyes showed prominent blue-shifted shoulder peaks for conjugates of the Cy dyes but only minor shoulder peaks for conjugates of the Alexa Fluor dyes. The anomalous peaks, previously observed for protein conjugates of the Cy5 dye, are presumably due to the formation of dye aggregates. Absorption of light by the dye aggregates does not result in fluorescence, thereby diminishing the fluorescence of the conjugates. The Alexa Fluor 555 and the Alexa Fluor 647 dyes in protein conjugates exhibited significantly less of this self-quenching, and therefore the protein conjugates of Alexa Fluor dyes were significantly more fluorescent than those of the Cy dyes, especially at high degrees of labeling. The results from our flow cytometry, immunocytochemistry, and immunohistochemistry experiments demonstrate that protein-conjugated, long-wavelength Alexa Fluor dyes have advantages compared to the Cy dyes and other long-wavelength dyes in typical fluorescence-based cell labeling applications.

Animals↗

CCR6 colocalizes with CD18 and enhances adhesion to activated endothelial cells in CCR6-transduced Jurkat T cells.

CCR6 is expressed by memory T cells (mTC) and is a requirement for efficient arrest of a subset of mTC to activated human dermal microvascular endothelial cells (HDMEC) under physiologic shear stress. We now address whether CCR6 alone is sufficient to induce arrest of a model T cell line (Jurkat) that shows low expression of all CCRs tested (CCR1-10). Herein, we transduced Jurkat (JK) T cells expressing fucosyltransferase VII with a chimeric chemokine receptor consisting of CCR6 fused to enhanced green fluorescent protein. In contrast to the starting JK lines, the resulting cell line (JK fucosyltransferase VII-CCR6) migrated 6-fold better to CCL20 in chemotaxis assays, arrested in response to CCL20 that was immobilized to plastic, and demonstrated a 2.5-fold increase in adhesion to activated HDMEC (p = 0.001). Adhesion was blocked by anti-CD18 mAb (p = 0.005) but not by anti-CD49d mAb (p = 0.3). After arrest on recombinant substrates, CCR6 clustered on the surface as detected by real-time observation of enhanced green fluorescent protein fluorescence. Dual-label confocal microscopy revealed that LFA-1 (CD18 and CD11a), but not CXCR4, colocalized with clustered CCR6 in the presence of immobilized CCL20. Thus, the functional expression of CCR6 is sufficient to provide the chemokine signaling necessary to induce arrest of a JK T cell line to activated HDMEC. Clustering of CCR6 and coassociation with critical integrins may serve to strengthen adhesion between T cells and activated endothelial cells.

Adjuvants, Immunologic↗

Detection of localized caspase activity in early apoptotic cells by laser scanning cytometry.

BACKGROUND: Caspase activation is a critical early step in the onset of apoptosis. Cell-permeable fluorogenic caspase substrates have proven valuable in detecting caspase activation by flow cytometry. Nevertheless, detection of early low-level caspase activation has been difficult using conventional area or peak fluorescence analysis by flow cytometry, despite the apparent presence of these cells as observed by microscopy. We describe a method utilizing maximum fluorescence pixel analysis by laser scanning cytometry (LSC) to detect early apoptotic cells. METHODS: The PhiPhiLux-G(1)D(2) caspase 3/7 substrate was used in combination with DNA dye exclusion and annexin V binding to identify several stages of apoptosis in EL4 murine thymoma cells by both traditional flow and LSC. LSC analysis of maximum pixel brightness in individual cells demonstrated an intermediate caspase-low subpopulation not detectable by flow or LSC integral analysis. LSC analysis of caspase activity was then carried out using the larger UMR-106 rat osteosarcoma cell line to determine if this apparent early caspase activity could be correlated with localized, punctate caspase activity observed by microscopy. RESULTS: The caspase-low subpopulation found in apoptotic EL4 cells was also observable in UMR-106 cells. Relocation to cells with low fluorescence due to caspase activity and subsequent examination by microscopy demonstrated that these latter cells indeed show punctate, highly localized caspase activation foci that might represent an early stage in caspase activation. CONCLUSIONS: Cells with low-level, localized caspase expression can be detected using maximum pixel analysis by LSC. This methodology allows an early step of apoptotic activation to be resolved for further analysis.

Animals↗