PubMed Health⌕ Search

Biomedical subjects

William Gray

Publications and source records attributed to William Gray.

7 recordsLinked to original sources

Mitral valve hemodynamic effects of percutaneous edge-to-edge repair with the MitraClip device for mitral regurgitation.

INTRODUCTION: The Endovascular Valve Edge-to-Edge REpair STudies (EVEREST) are investigating a percutaneous technique for edge-to-edge mitral valve repair with a repositionable clip. The effects on the mitral valve gradient (MVG) and mitral valve area (MVA) are not known. METHODS: Twenty seven patients with moderate to severe or severe mitral regurgitation (MR) were enrolled. Echocardiography was performed preprocedure, at discharge, and at 1, 6, and 12 months. Mean MVG was measured by Doppler and MVA by planimetry and pressure half-time, and evaluated in a central core laboratory. Pre- and postclip deployment, simultaneous left atrial/pulmonary capillary wedge and left ventricular pressures were obtained in eight patients. RESULTS: Three patients did not receive a clip, six patients had their clip(s) explanted by 6 months (none for mitral stenosis), and four were repaired with two clips. Results are notable for a slight increase in mean MVG by Doppler postclip deployment (1.79 +/- 0.89 to 3.31 +/- 2.09 mm Hg, P < 0.01) and an expected decrease in MVA by planimetry (6.49 +/- 1.61 to 4.46 +/- 2.14 cm(2), P < 0.001) and by pressure half time (4.35 +/- 0.98 to 3.01 +/- 1.42 cm(2), P < 0.05). There were no significant changes in hemodynamic parameters postclip deployment by direct pressure measurements. There was no change in MVA by planimetry from discharge to 12 months (3.90 +/- 1.90 to 3.79 +/- 1.54 cm(2), P = 0.78). CONCLUSIONS: Echocardiographic and hemodynamic measurements after percutaneous mitral valve repair with the MitraClip show an expected decrease in mitral valve area with no evidence of clinically significant mitral stenosis either immediately after clip deployment or after 12 months of follow-up.

Aged↗

Percutaneous mitral valve repair using the edge-to-edge technique: six-month results of the EVEREST Phase I Clinical Trial.

OBJECTIVES: This study sought to evaluate the clinical results of a percutaneous approach to mitral valve repair for mitral regurgitation (MR). BACKGROUND: A surgical technique approximating the middle scallops of the mitral leaflets to create a double orifice with improved leaflet coaptation was introduced in the early 1990s. Recently, a percutaneous method to create the same type of repair was developed. A trans-septal approach was used to deliver a clip device that grasps the mitral leaflet edges to create the double orifice. METHODS: General anesthesia, fluoroscopy, and echocardiographic guidance are used. A 24-F guide is positioned in the left atrium. The clip is centered over the mitral orifice, passed into the left ventricle, and pulled back to grasp the mitral leaflets. After verification that MR is reduced, the clip is released. RESULTS: Twenty-seven patients had six-month follow-up. Clips were implanted in 24 patients. There were no procedural complications and four 30-day major adverse events: partial clip detachment in three patients, who underwent elective valve surgery, and one patient with post-procedure stroke that resolved at one month. Three additional patients had surgery for unresolved MR, leaving 18 patients free from surgery. In 13 of 14 patients with reduction of MR to < or =2+ after one month, the reduction was maintained at six months. CONCLUSIONS: Percutaneous edge-to-edge mitral valve repair can be performed safely and a reduction in MR can be achieved in a significant proportion of patients to six months. Patients who required subsequent surgery had elective mitral valve repair or intended replacement.

Aged↗

Patent foramen ovale: current pathology, pathophysiology, and clinical status.

Patent foramen ovale (PFO) is experiencing increased clinical interest as a congenital cardiac lesion persisting into adulthood. It is implicated in several serious clinical syndromes, including stroke, myocardial infarction, and systemic embolism. The PFO is now amenable to percutaneous interventional therapies, and multiple novel technologies are either available or under development for lesion closure. The PFO should be better understood to take advantage of emerging percutaneous treatment options. This paper reviews PFO anatomy, pathology, pathophysiology, and clinical impact and discusses current therapeutic options.

Heart Septal Defects, Atrial↗

Nonconvulsive status epilepticus: Epilepsy Research Foundation workshop reports.

In April 2004, a group of physicians with an interest in nonconvulsive status epilepticus representing a spectrum of opinion met in Oxford, sponsored by the Epilepsy Research Foundation (a charitable organization), to discuss and debate the definition, diagnosis and treatment of nonconvulsive status epilepticus. We felt that such a meeting would be useful, as nonconvulsive status epilepticus is a subject that provokes strong reactions, perhaps largely due to the relative lack of evidence and the surfeit of opinion. The meeting was arranged such that there were formal talks followed by a discussion led by one of the attendees. We present here the extended abstracts of the main talks with the points raised by the discussants. Despite disagreements on certain issues there was much in the way of consensus. First, it was agreed that nonconvulsive status epilepticus is a term that covers a range of disparate conditions with varying prognoses and treatments. The agreed definition was thus suitably vague, A< >. Secondly, it was agreed that even within a specific condition (e.g. complex partial status epilepticus), the prognosis and treatment depends upon the context in which the condition occurs (e.g. in the critically ill, in coma, in the A< > and in people with prior epilepsy). Perhaps, most importantly it was agreed that we lacked good clinical data, and the challenge was to design good studies for a condition that is underrecognised and often difficult to diagnose.

Brain Damage, Chronic↗

Left atrial structure and function after percutaneous left atrial appendage transcatheter occlusion (PLAATO): six-month echocardiographic follow-up.

OBJECTIVES: This study was designed to evaluate the effects of percutaneous left atrial appendage transcatheter occlusion (PLAATO) on the anatomic and hemodynamic properties of the mitral valve (MV) and left upper pulmonary vein (LUPV). BACKGROUND: PLAATO is a device designed to seal the neck of the left atrial (LA) appendage and reduce embolization in patients with atrial fibrillation intolerant of warfarin. The impact of deployment of this device on adjacent structures has not been reported. METHODS: Patients with atrial fibrillation participating in the ongoing study for evaluation of PLAATO were enrolled. Transesophageal echocardiographies at baseline, one, and six months were reviewed to measure LA and LUPV dimensions, degree of mitral regurgitation, stability of the device, peak MV E-wave velocity, and peak systolic and diastolic flow velocities in the LUPV. Data were analyzed by a linear mixed model for repeated measures. RESULTS: Eleven patients (mean age of 72 +/- 7 years) completed six months of follow-up. Left upper pulmonary vein diameter (mean: 1.55, 1.61, 1.54 cm, p = 0.13) and peak systolic (mean: 0.38, 0.34, 0.31 m/s, p = 0.72) and diastolic flow velocities (mean: 0.39, 0.40, 0.42 m/s, p = 0.46) did not differ over the follow-up period. Left atrial size, mitral regurgitation severity, and MV peak E-wave velocities (mean: 0.94, 0.94, 0.82 m/s, p = 0.58) showed no significant change from baseline. The devices remained stable at their sites of deployment with minimal residual flow around them. CONCLUSIONS: PLAATO achieved an adequate seal of the neck of the left atrial appendage without significant effect on the structure or function of the LA and LUPV.

Aged↗

Incidence of aspirin nonresponsiveness using the Ultegra Rapid Platelet Function Assay-ASA.

We report the incidence of aspirin nonresponsiveness in a prospective, multicenter registry (n=422 patients) to be 23% using the Ultegra Rapid Platelet Function Assay-ASA, and determined a history of coronary artery disease to be associated with twice the odds of being an aspirin nonresponder (odds ratio 2.01, 95% confidence interval 1.189 to 3.411, p=0.009). Further prospective studies are needed to correlate aspirin nonresponsiveness to adverse clinical events.

Aspirin↗