PubMed Health⌕ Search

Biomedical subjects

William J Ciccone

Publications and source records attributed to William J Ciccone.

4 recordsLinked to original sources

Viscoelasticity and temperature variations decrease tension and stiffness of hamstring tendon grafts following anterior cruciate ligament reconstruction.

BACKGROUND: Hamstring tendon grafts used for anterior cruciate ligament reconstruction are typically harvested early in the surgical procedure and are preconditioned prior to reimplantation. Postoperatively, the grafts undergo stress relaxation and warm from the temperature of the operating room to body temperature. The hypothesis of this study was that the tension within semitendinosus and gracilis tendon grafts and the stiffness of the grafts significantly decrease postoperatively because of both stress relaxation and an increase in temperature. METHODS: Double-strand grafts were created from six semitendinosus tendons and six gracilis tendons harvested from cadaver specimens. The grafts were loaded to 65 N while at operating-room temperature (20 degrees C). After fifteen minutes of stress relaxation, graft tension was measured and the grafts were stretched by 0.1 mm to determine stiffness. The tension and stiffness measurements represented graft properties immediately following reconstruction. Additional tension and stiffness measurements were made following three hours of stress relaxation and after increasing the temperature to the body temperature at the knee (34 degrees C). Both types of graft were examined for differences in stiffness and tension due to stress relaxation and the temperature increase. RESULTS: For both types of graft, the tension and stiffness decreased following stress relaxation to approximately 50% and 80%, respectively, of the value immediately after reconstruction. Increasing the temperature decreased the tension and stiffness further to approximately 40% and 70%, respectively, of the value after reconstruction for both types of graft. All changes in tension and stiffness were significant (p < 0.01). CONCLUSIONS: Graft tension and stiffness achieved immediately following reconstruction are not maintained postoperatively because of stress relaxation and a temperature increase. This could lead to increased knee laxity.

Aged↗

Structural properties of lateral collateral ligament reconstruction at the fibular head.

BACKGROUND: Anatomical reconstruction of a ruptured lateral collateral ligament using allograft tissue secured within the fibular head with an interference screw has been described. HYPOTHESIS: Interference fixation at the fibular head does not reproduce the strength of the intact ligament. STUDY DESIGN: Controlled laboratory study. METHODS: Ten intact lateral collateral ligaments were tested to failure. The distal fixation of 11 ligaments reconstructed with a graft including a bone plug and 11 ligaments reconstructed with a graft without a bone plug were also tested. RESULTS: The reconstructed ligaments consistently failed at the fibular head. The intact specimens predominately failed through ligament rupture. The mean strength and stiffness values were 460 +/- 163 N and 82 +/- 25 N/mm, respectively, for the intact ligaments, 113 +/- 40 N and 36 +/- 10 N/mm, respectively, for reconstruction with a bone plug, and 135 +/- 81 N and 34 +/- 14 N/mm, respectively, for reconstruction without a bone plug. The strength and stiffness were significantly (P < .05) greater for the intact ligaments than for either reconstruction group. The variation in strength was significantly larger for reconstruction without a bone plug than for reconstruction with a bone plug. CONCLUSION: Tension applied to lateral collateral ligaments reconstructed using fibular interference fixation should be limited immediately after surgery. Soft tissue fixation should be employed with care because of the inconsistency in the failure strength. CLINICAL RELEVANCE: Although fibular interference fixation is increasingly being described in the literature, the properties of reconstructed lateral collateral ligaments have not previously been quantified.

Bone Screws↗

Simplified arthroscopic suture passing using a suture loop.

Arthroscopic procedures for shoulder pathology are becoming more popular. Passing braided nonabsorbable suture for repair of intra-articular tissue can be technically difficult because advancing this suture through tissue is a 2-step process. The use of a suture loop with Spectrum suture hooks (Linvatec, Largo, FL) simplifies braided suture passing, and eliminates the use of expensive suture shuttles. This technique simplifies the use of nonabsorbable suture in arthroscopic shoulder procedures.

Arthroscopy↗

Locking plates improve torsional resistance in the stabilization of three-part proximal humeral fractures.

This study quantified the torsional resistance provided by locking plates and angled blade plates used to stabilize proximal humeral fractures. Three-part proximal humeral fractures were created in 6 pairs of cadaveric humeri. One specimen of each pair was reconstructed with a proximal humeral locking plate, whereas the other specimen was reconstructed with an angled blade plate. An external rotation torque, varying from 0 to 5 N-m, was applied to the humeral head until the head rotated 30 degrees or 10,000 loading cycles were applied. The mean initial torsional stiffness was significantly larger for the locking plates (0.99 N-m/degree) than for the blade plates (0.59 N-m/degree). For each pair, the maximum rotation was larger for the blade plate than for the locking plate. For this in vitro model of a reconstructed 3-part proximal humeral fracture, the locking plate provided better torsional fatigue resistance and stiffness than the blade plate.

Aged↗