PubMed Health⌕ Search

Biomedical subjects

William Lee

Publications and source records attributed to William Lee.

6 recordsLinked to original sources

Validation of a sensitive assay for thiocoraline in mouse plasma using liquid chromatography-tandem mass spectrometry.

A sensitive high-performance liquid chromatography-tandem mass spectrometry assay for thiocoraline, an anti-tumor depsipeptide, in mouse plasma is described. Echinomycin, a quinoxaline peptide, was used as an internal standard. Thiocoraline was recovered from the mouse plasma using protein precipitation with acetonitrile and followed by solid-phase extraction of the supernatant. The mobile phase consisted of methanol (0.1% formic acid)-water (0.1% formic acid) (90:10, v/v). The analytical column was a YMC C(18). The standard curve was linear from 0.1 to 50 ng/ml (R(2)>0.99). The lower limit of quantitation was 0.1 ng/ml. The assay was specific based on the multiple reaction monitoring transitions at m/z 1157-->215 and m/z 1101-->243 for thiocoraline and the internal standard, echinomycin, respectively. The mean intra- and inter-day assay accuracies remained below 5 and 12%, respectively, for all calibration standards and quality control (QC) samples. The intra- and inter-day assay precisions were less than 11.4 and 9.5% for all QC levels, respectively. The utility of the assay was demonstrated by a pharmacokinetic study of i.v. (bolus) thiocoraline on CD-1 mice. Thiocoraline was stable in mouse plasma in an ice-water bath for 6 h and for three freeze-thaw cycles. The reconstituted thiocoraline after extraction and drying sample process was stable in the autosampler for over 24 h. The assay was able to quantify thiocoraline in plasma up to 48 h following dose. Pharmacokinetic analysis showed that thiocoraline has distinct pharmacokinetic profiling when dosed in different formulation solutions. The assay is currently used to measure thiocoraline plasma concentrations in support of a project to develop a suitable formulation with a desirable pharmacokinetic profile.

Animals↗

Protein binding to polymer brush, based on ion-exchange, hydrophobic, and affinity interactions.

The major limitations associated with conventional packed bed chromatography for protein separation and purification can be overcome by using adsorptive microporous membranes as chromatographic media. Microporous membranes have advantages as support matrices in comparison to conventional bead supports because they are not compressible and they eliminate diffusion limitations. As a result, higher throughput and shorter processing times are possible using these membrane systems. In this paper, we review the current state of development in the area of attaching functionalized polymer brushes onto a microporous membrane to form a novel chromatographic medium for protein separation and purification. The functionalized polymer brushes were appended onto the pore surface of a microporous hollow-fiber membrane uniformly across the membrane thickness by radiation-induced graft polymerization and subsequent chemical modifications. We review various applications of this adsorptive membrane chromatography by focusing on polymer brushes bearing ion-exchange, hydrophobic and affinity groups. Proteins were captured in multilayers by the ion-exchange group-containing polymer brushes due to the formation of a three-dimensional space for protein binding via the electrostatic repulsion of the polymer brushes. In contrast, proteins were captured in a monolayer at most by the polymer brushes containing hydrophobic or affinity ligands. By permeating a protein solution through the pores rimmed by the polymer brushes, an ideal capturing rate of the proteins with a negligible diffusional mass-transfer resistance was achieved by the functionalized polymer brushes, based on ion-exchange, hydrophobic, and affinity interactions.

Chromatography, Affinity↗

Development of a liquid chromatography/tandem mass spectrometry assay for the quantification of Aplidin, a novel marine-derived antineoplastic agent, in human plasma.

A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay was developed and validated to quantify a novel marine-derived depsipeptide, Aplidin, in human plasma. The method was validated to demonstrate the specificity, recovery, limit of quantitation (LOQ), accuracy, and precision of measurements. The calibration range for Aplidin was established using Aplidin standards from 0.05-50 ng/mL in blank human plasma. The multiple reaction monitoring, based on the transition m/z 1110.7 --> 295.3, was specific for Aplidin, and that based on the transition m/z 1112.6 --> 297.3 was specific for didemnin B (the internal standard); no endogenous materials interfered with the analysis of Aplidin and didemnin B from blank human plasma. The assay was linear over the concentration range 0.05-50.0 ng/mL. The correlation coefficients for the calibration curves ranged from 0.9979 to 0.9999. The mean intra- and interday accuracies for all calibration standards (n = 12) ranged from 97 to 106% (</=6% bias), and the mean interday precision for all calibration standards was less than 8.3%. The mean intra- and interday assay accuracy for all quality control replicates (n = 12), determined at each QC level throughout the validated runs, remained below 12 and 7%, respectively. The mean intra- and interday assay precision was less than 13.1 and 10.7% for all QC levels, respectively. The assay is currently used to measure Aplidin plasma concentrations to support clinical trials.

Antineoplastic Agents↗

Genome-tools: a flexible package for genome sequence analysis.

Genome-tools is a Perl module, a set of programs, and a user interface that facilitates access to genome sequence information. The package is flexible, extensible, and designed to be accessible and useful to both nonprogrammers and programmers. Any relatively well-annotated genome available with standard GenBank genome files may be used with genome-tools. A simple Web-based front end permits searching any available genome with an intuitive interface. Flexible design choices also make it simple to handle revised versions of genome annotation files as they change. In addition, programmers can develop cross-genomic tools and analyses with minimal additional overhead by combining genome-tools modules with newly written modules. Genome-tools runs on any computer platform for which Perl is available, including Unix, Microsoft Windows, and Mac OS. By simplifying the access to large amounts of genomic data, genome-tools may be especially useful for molecular biologists looking at newly sequenced genomes, for which few informatics tools are available. The genome-tools Web interface is accessible at http://genome-tools.sourceforge.net, and the source code is available at http://sourceforge.net/projects/genome-tools.

Base Sequence↗

Highly multilayered urease decomposes highly concentrated urea.

Urease was immobilized at a density of 1.2 g of urease per gram of a matrix via ion-exchange binding of urease to an anion-exchange polymer chain grafted onto a pore surface of a porous hollow-fiber membrane and subsequent cross-linking of urease with transglutaminase. Urea was hydrolyzed during the permeation of a urea solution, the concentration of which ranged from 2 to 8 M, through the pores of the resultant membrane with a thickness of approximately 1 mm. Quantitative hydrolysis of 4 M urea was achieved at a permeation rate lower than 1 mL/h, i.e., a residence time longer than 5.1 min, at ambient temperature. This performance is ascribed to convective transport of urea through the pores rimmed by the urease-immobilized polymer chains at a high density. Urease was denatured in the presence of urea at concentrations higher than 6 M while hydrolyzing urea.

Adsorption↗