PubMed Health⌕ Search

Biomedical subjects

William R Riddle

Publications and source records attributed to William R Riddle.

5 recordsLinked to original sources

Implementing pediatric growth charts into an electronic health record system.

Electronic health record (EHR) systems are increasingly being adopted in pediatric practices; however, requirements for integrated growth charts are poorly described and are not standardized in current systems. The authors integrated growth chart functionality into an EHR system being developed and installed in a multispecialty pediatric clinic in an academic medical center. During a three-year observation period, rates of electronically documented values for weight, stature, and head circumference increased from fewer than ten total per weekday, up to 488 weight values, 293 stature values, and 74 head circumference values (p<0.001 for each measure). By the end of the observation period, users accessed the growth charts an average 175 times per weekday, compared to 127 patient visits per weekday to the sites that most closely monitored pediatric growth. Because EHR systems and integrated growth charts can manipulate data, perform calculations, and adapt to user preferences and patient characteristics, users may expect greater functionality from electronic growth charts than from paper-based growth charts.

Adolescent↗

Extracting data from a DICOM file.

DICOM v3.0 is a vendor-independent standard for digital medical images that describes a file format and network protocol for the exchange of images between computer systems. When simply viewing a DICOM file, it is not necessary for the user to understand the details of the entire DICOM standard. However, understanding parts of the standard is essential when DICOM files are read and processed by a user-generated program. This paper offers an overview of information a user needs to write a program for extracting the image and acquisition parameters from a DICOM file.

Computer Communication Networks↗

Characterizing changes in MR images with color-coded Jacobians.

Image registration is the process of establishing spatial correspondence between two images or between two image volumes. Registration can be achieved by rigid, elastic, or a combination of rigid and elastic transforms that attempt to bring the two images into coincidence. A rigid transform accounts for differences in positioning and an elastic transform describes deformations due to differences in tissue properties, temporal changes due to growth or atrophy, or differences between individuals. Deformation-based morphometry uses the resulting deformation fields from these transforms to evaluate differences between the images being registered. Three methods of registration were evaluated: rigid (affine) transformation, elastic optical flow transformation, and elastic spline transformation. All three methods produce vector deformation fields that map each point in one image to a point in the other image. A 12-color map of the transformation Jacobian was used to represent local volume changes. Using the three registration methods, color-mapped Jacobians were determined using a simulated three-dimensional block with known translation, rotation, expansion, contraction, and intensity modulations. Color-coded Jacobians were also generated for experimentally measured magnetic resonance image volumes of water-filled balloons and 7-year-old twin boys. Color-coded Jacobians overlaid on anatomical images provide a convenient method to identify regional tissue expansion and contraction.

Algorithms↗

Longitudinal brain metabolic characterization of chronic alcoholics with proton magnetic resonance spectroscopy.

BACKGROUND: Proton magnetic resonance spectroscopy may elucidate the molecular underpinnings of alcoholism-associated brain shrinkage and the progression of alcohol dependence. METHODS: Using proton magnetic resonance spectroscopy, we determined absolute concentrations of -acetylaspartate (NAA), creatine/phosphocreatine (Cr), and choline (Cho)-containing compounds and -inositol (mI) in the anterior superior cerebellar vermis and frontal lobe white matter in 31 alcoholics and 12 normal controls. All patients were examined within 3 to 5 days of their last drink. Patients who did not relapse were again studied after 3 weeks and 3 months of abstinence by using an on-line repositioning technique that allows reliable localization of volumes of interest (VOIs). RESULTS: At 3 to 5 days after the last drink, frontal white matter metabolite concentrations were not significantly different from those of normal controls, whereas brain tissue in the VOI was reduced. Cerebellar [NAA] and [Cho] and brain and cerebellar volumes were decreased, but [Cr], [mI], and VOI brain tissue volume were not significantly different. Eight patients relapsed before 3 weeks (ER), 12 relapsed between 3 weeks and 3 months (LR), and 11 did not relapse (NR) during 3 months. Cerebellar [NAA] was reduced only in ER patients, despite the fact that ER patients drank for significantly fewer years and earlier in life than LR or NR patients. After 3 months, in the 11 continuously abstinent patients, cerebellar [NAA] and brain and cerebellar volumes increased; cerebellar [Cho], [Cr], and [mI] and VOI brain tissue did not change significantly. CONCLUSIONS: Decreased [NAA] and [Cho] in cerebellar vermis indicate a unique sensitivity to alcohol-induced brain injury. Cerebellar [NAA] increased with abstinence, but reduced [Cho] persisted beyond 3 months. Further studies are needed to determine whether low cerebellar [NAA] is a risk factor for, or consequence of, malignant, early-onset alcoholism.

Adult↗

Proton magnetic resonance spectroscopy in the brain: report of AAPM MR Task Group #9.

AAPM Magnetic Resonance Task Group #9 on proton magnetic resonance spectroscopy (MRS) in the brain was formed to provide a reference document for acquiring and processing proton (1H) MRS acquired from brain tissue. MRS is becoming a common adjunct to magnetic resonance imaging (MRI), especially for the differential diagnosis of tumors in the brain. Even though MR imaging is an offshoot of MR spectroscopy, clinical medical physicists familiar with MRI may not be familiar with many of the common practical issues regarding MRS. Numerous research laboratories perform in vivo MRS on other magnetic nuclei, such as 31P, 13C, and 19F. However, most commercial MR scanners are generally only capable of spectroscopy using the signals from protons. Therefore this paper is of limited scope, giving an overview of technical issues that are important to clinical proton MRS, discussing some common clinical MRS problems, and suggesting how they might be resolved. Some fundamental issues covered in this paper are common to many forms of magnetic resonance spectroscopy and are written as an introduction for the reader to these methods. These topics include shimming, eddy currents, spatial localization, solvent saturation, and post-processing methods. The document also provides an extensive review of the literature to guide the practicing medical physicist to resources that may be useful for dealing with issues not covered in the current article.

Artifacts↗