PubMed Health⌕ Search

Biomedical subjects

William R Walsh

Publications and source records attributed to William R Walsh.

At least 19 recordsLinked to original sources

Evaluation of a bioresorbable polylactide sheet for the reduction of pelvic soft tissue attachments in a porcine animal model.

In an adult porcine model, the effectiveness of a bioresorbable film to minimize soft tissue attachment to the pelvic viscera was evaluated at 4-week and 12-week endpoints. Following a transperitoneal laparotomy through a midline incision, the bladder and uterus were abraded in all animals to promote soft tissue attachment to the viscera. Control animals received no further treatment. The experimental group animals were treated with bioresorbable polylactide (PLa) sheets, 0.02 mm thick, one between the bladder and the abdominal wall, and a second sheet between the bladder and the uterus. Quantitative assessment of the severity and location of soft tissue attachments, and qualitative histologic assessment were performed at 4 and 12 weeks post-operatively. Statistically significant differences in the quantitative soft tissue attachment scores were observed in comparing the PLa film treated animals versus the control animals, at both the 4-week and 12-week time points. In the control animals, the formation of numerous thick fibrous bands was observed at both time points. Histology revealed no adverse reaction to the bioresorbable PLa barrier film. The bioresorbable PLa sheet provided an effective barrier between adjacent anatomical structures and minimized soft tissue attachments to the device when in contact with the viscera as compared to the control groups. Surgical dissection planes between the abdominal wall and adjacent soft tissues were maintained with the use of the PLa sheet at both time points.

Absorbable Implants↗

The influence of ambient theater temperature on cement setting time.

We have prospectively recorded ambient operating theater temperature from 186 total knee arthroplasties and the time taken for the cement to set at implantation. The majority of cases used Antibiotic Simplex cement (n = 131), and the rest, Simplex with tobramycin (n = 55). Set time was defined as when a no. 15 scalpel could not indent the cement surface at either the femoral or tibial interface. There was a reasonable negative correlation between temperature and setting time (Antibiotic Simplex: Pearson correlation coefficient, R = -0.674; Simplex with tobramycin: R = -0.655). There was also a considerable variation of setting time at any given theater temperature. There is an inverse relationship between ambient theater temperature and the setting time for Simplex cement, and surgeons should be aware that the setting time can vary considerably. Their operative protocol should take this into account.

Aged↗

In vitro study of shear force on interbody implants.

OBJECTIVE: The lordosis of the lumbar spine and body weight result in significant shear forces through the lumbosacral disc spaces. These forces result in translational motion across the disc space, which is resisted but not completely abolished by pedicle screw stabilization. It is postulated that this motion may be a factor in the development of nonunion of lumbar interbody fusions. An in vitro study of the micromotion of porcine specimens implanted with serrated or smooth interbody spacers and subjected to shear forces under compressive preload was conducted to determine whether the surface serrations on vertebral interbody implants significantly resist shear forces and resulting sagittal translation. METHODS: Measurements of anterior vertebral translation were recorded on porcine cervical spine segments, subjected to 25 N of anteroposterior shear load while under a 300-N compressive preload. Baseline testing was performed on intact specimens and partially destabilized specimens (facet joints removed). Following partial discectomy, the specimens were divided into two groups for testing: one using smooth-surfaced and one using serrated interbody spacers. RESULTS: Under 25-N shear load, the specimens tested with the serrated spacers showed anterior vertebral translation of 0.046 +/- 0.013 mm, whereas those tested with the smooth spacers measured 0.152 +/- 0.075 mm (P < 0.01). CONCLUSIONS: The presence of surface serrations on the interbody implants significantly increased the resistance to shear forces in this model. In the clinical setting, we postulate that micromotion at interbody fusion sites will be substantially less when serrated implants are used and may help reduce the incidence of nonunion.

Animals↗

Growth factor expression following clinical mandibular distraction osteogenesis in humans and its comparison with existing animal studies.

AIM: Lengthening the mandible by distraction osteogenesis (DO) is nowadays a well recognized technique in maxillofacial surgery. In this study growth factor expression profiles were examined in biopsies taken from six patients undergoing mandibular DO and compared with findings from a sheep model for mandibular DO. STUDY DESIGN: In all patients (and sheep), the ascending ramus was distracted 10-15 mm at a rate of 1mm/day using an intraoral device. Biopsies were taken from the centre of the distraction zone 21 days after completion of distraction. Using standard immunohistochemical techniques, samples were stained for platelet-derived growth factor (PDGF), transforming growth factor beta (TGF-beta), basic fibroblast growth factor (bFGF) and bone morphogenetic proteins-2, -4 and -7 (BMP-2, -4, -7), matrix metalloproteinases-1 and -3 (MMP-1, -3), the vascular endothelial growth factor (VEGF), a marker for endothelial cells (CD-31) and type IV collagen (Col IV). RESULTS: Positive staining for PDGF, bFGF, TGF-beta, BMP-2, -4, and -7 was noted in cells and matrix components. There was intense staining for MMP-1. Strong staining for CD-31 and COL IV was observed adjacent to vessels. VEGF staining was less specific. Similar findings were noted in the sheep model. CONCLUSION: Growth factor expression in the human distraction site is similar to that in the sheep model.

Adolescent↗

Suture strength and angle of load application in a suture anchor eyelet.

PURPOSE: To assess the effect of suture material, anchor orientation, and anchor eyelet design on the static loading properties of suture anchors. TYPE OF STUDY: Biomechanical bench study. METHODS: Two metallic suture anchors, Mitek GII (Mitek, Westwood, MA) and Corkscrew (Arthrex, Naples, FL) and a bioabsorbable anchor (Biocorkscrew; Arthrex) were tested with single strand of No. 2 Ethibond (Ethicon, Norderstedt, Germany) or No. 2 FiberWire (Arthrex) suture. Suture pull angle was varied through 0 degrees, 45 degrees, and 90 degrees with the anchor rotation angle in either a sagittal or coronal plane. Constructs were tested to failure using an MTS 858 Bionix testing machine (Material Testing Systems, Eden Prairie, MN). Peak loads, stiffness, energy to peak load, and failure modes were determined for all samples. RESULTS: FiberWire showed superior static mechanical properties when compared with single-strand Ethibond over all testing conditions (P < .05). Suture pull angle had a significant effect on load to failure with both metallic anchors but not on the bioabsorbable anchor (P < .05). CONCLUSIONS: Suture pull angle and anchor rotation angle play an important role in the failure load of suture when placed in an eyelet. The polyaxial nature of the Biocorkscrew eyelet allows for increased degrees of freedom but introduces failure of the suture eyelet as a new failure mode. CLINICAL RELEVANCE: The loading direction and placement of the suture anchor plays a role in the performance of the suture anchor-suture complex.

Absorbable Implants↗

Cyclic testing of pullout sutures and micro-mitek suture anchors in flexor digitorum profundus tendon distal fixation.

PURPOSE: Little data exist comparing the strength of traditional methods of fixation in a flexor digitorum profundus tendon with the use of a suture anchor. In vitro cyclic testing simulating a passive mobilization protocol was used to compare the repair of a flexor digitorum profundus tendon using a single micro-Mitek anchor (Mitek, Westwood, MA) or a modified Bunnell 2-strand pullout technique using a monofilament or a braided polyester suture. METHODS: Twenty-four fresh-frozen cadaveric fingers were divided randomly into 4 repair groups (n = 6 each): a micro-Mitek with a 3-0 braided polyester suture or a 3-0 monofilament suture, or a modified Bunnell technique with a 3-0 braided polyester suture or a 3-0 monofilament suture. After repair the specimens were loaded cyclically from 2 to 15 N at 5 N/s, for a total of 500 cycles. Gap formation at the tendon-bone interface was assessed every 100 cycles. Samples were tested to failure at the completion of 500 cycles. RESULTS: No specimens failed catastrophically during cyclic testing. A significantly greater gap formed using the monofilament sutures compared with the braided polyester sutures with both repair techniques. Load to failure in the modified Bunnell technique was superior to the micro-Mitek with both suture types. The modified Bunnell technique using a braided polyester suture was superior to the monofilament suture whereas the suture type did not alter the properties of the micro-Mitek repair. CONCLUSIONS: Significant gap formation with the use of a monofilament suture may be of concern. The use of a braided polyester suture when removal of the pullout suture is required as in the Bunnell technique also needs to be considered.

Aged↗

The effect of rate of distraction osteogenesis on structure and function of anterior digastric muscle fibers.

The authors hypothesized that distraction at a rate of 3 mm/day, compared with mandibular distraction at a rate of 1 mm/day, would produce a maladaptive response in adjacent muscles of mastication. The authors further hypothesized that the maladaptive response would manifest at the single fiber level by means of increased sarcomeric heterogeneity, decreased maximum force output, and increased susceptibility to stretch-induced injury. In an ovine model, distraction osteogenesis of the right hemimandible was performed at either 1 mm/day for 21 days (n = 2) or 3 mm/day for 7 days (n = 2) to achieve a total distraction distance of 21 mm. The left hemimandibles served as controls. After a consolidation period of 2 days, the anterior digastric muscles were harvested; in six randomly selected single fibers from each muscle, maximum calcium-activated force (Po) was measured at optimal sarcomere length. The amount of damage to the sarcomeres in each fiber was assessed microscopically. To test susceptibility to contraction-induced injury, each fiber was given an activated stretch of 20 percent. Compared with control fibers and fibers distracted at 1 mm/day, maximum tetanic force (Po) was significantly lower in fibers distracted at 3 mm/day. Compared with control fibers, specific Po (Po/cross-sectional area) was lower in fibers distracted at 3 mm/day. The number of sarcomeres appearing damaged in fibers distracted at 3 mm/day was significantly higher than in control fibers or in fibers distracted at 1 mm/day. A greater deficit in Po was observed after a single activated stretch in fibers distracted at 3 mm/day than in control fibers or in fibers distracted at 1 mm/day. The authors conclude that distraction of the anterior digastric muscle in sheep at 3 mm/day produces a maladaptive response in the muscle fibers but a rate of 1 mm/day is tolerated by the muscle fibers. These data are consistent with the hypothesis that distraction of skeletal muscle at high rates results in increased heterogeneity of sarcomere lengths and that this increase in heterogeneity is the most likely potential mechanism resulting in whole muscle force deficits and in increased susceptibility to stretch-induced injury in distracted muscles.

Animals↗

Adhesion formation after flexor tendon repair: comparison of two- and four-strand repair without epitendinous suture.

Increased handling, increased bulk at the repair site and an increase in external suture material may affect adhesion formation and gliding after tendon repair. A previous study(1) showed no significant difference in biomechanical or histopathological measurement of adhesion formation in two- and four-strand repairs combined with an epitendinous suture in the chicken model. In the present study, the flexor digitorum profundus tendon of the middle toe of 47 broiler chickens was cut and repaired with either a single (two-strand) or double (four-strand) modified Kessler core suture without epitendinous suture and immobilised for four weeks. Adhesion formation was measured by biomechanical testing or quantitative and qualitative histopathology. Biomechanical and histological data showed no differences between two- and four-strand repairs. Results did not differ from the previous study which used an epitendinous suture. Adhesion formation is not necessarily increased when multi-strand techniques are used, nor by the placement of an epitendinous suture if care is taken with surgical technique. Individual healing response introduces more variability than an increase in tendon handling by an experienced surgeon.

Animals↗

Differential expression of osteogenic factors associated with osteoinductivity of human osteosarcoma cell lines.

Differential expression of multiple osteogenic factors may be responsible for the different osteoinductivity of osteosarcoma cell lines. We compared in vivo osteoinductivity of human osteosarcoma cell lines (Saos-2 vs. U-2 OS) in nude mice, and their in vitro expression of various osteogenic factors of protein level by quantitative immunocytochemistry and mRNA level by RT-PCR and/or in situ hybridization. Saos-2 cells, but not U-2 OS, were osteoinductive in vivo. Significantly higher expression (independent t-test, all p < 0.005) of osteogenic factors were observed in Saos-2 cells compared with U-2 OS, which included bone morphogenetic proteins (particularly BMPs-2, 3, 4, and 7), transforming growth factor-beta (TGF-beta), BMP receptor (BMPR)-1A, receptor-regulated Smads (R-Smads), Smads 1, 2, and 5, and common-mediator Smad (Co-Smad), Smad 4. In contrast, U-2 OS cells expressed higher levels of inhibitory Smad 6 (I-Smad) protein than Saos-2 cells (p < 0.001). These results suggest that a combination of osteogenic factors (BMPs, TGF-beta, BMPRs, and R/Co-Smads) against I-Smad may play important roles in the Saos-2 cell osteoinductivity. This may have a clinical implication in selecting key osteogenic factors for combined therapy for bone defect diseases. The characterized cell lines can be used as positive and negative controls for the assessments of both in vitro and in vivo bone formation capabilities of designed tissues or biomaterials.

Animals↗

Spinal fusion using an autologous growth factor gel and a porous resorbable ceramic.

Augmenting healing through a single application of an exogenous growth factor or bone morphogenetic protein is not a new concept. The use of autologous growth factors through platelet isolation and concentration provides multiple endogenous growth factors to the healing site. A posterolateral fusion model in aged sheep (5- to 6-year-old ewes) was used to examine the effects of the addition of growth factors through autologous platelet isolation on the biomechanic and histologic properties of the fusion using a resorbable coral bone graft substitute. At 6 months the combination of autologous growth factors to the Pro Osteon 500R plus aspirated bone marrow resulted in the greatest bending stiffness but not ultimate load. Autologous growth factors can be isolated from platelets and concentrated to provide multiple growth factors to the fusion site to aid in spinal fusion.

Animals↗

Multiaxial pedicle screw designs: static and dynamic mechanical testing.

STUDY DESIGN: Randomized investigation of multiaxial pedicle screw mechanical properties. OBJECTIVES: Measure static yield and ultimate strengths, yield stiffness, and fatigue resistance according to an established model. Compare these measured properties with expected loads in vivo. SUMMARY OF BACKGROUND DATA: Multiaxial pedicle screws provide surgical versatility, but the complexity of their design may reduce their strength and fatigue resistance. There is no published data on the mechanical properties of such screws. MATERIALS AND METHOD: Screws were assembled according to a vertebrectomy model for destructive mechanical testing. Groups of five assemblies were tested in static tension and compression and subject to three cyclical loads. Modes of failure, yield, and ultimate strength, yield stiffness, and cycles to failure were determined for six designs of screw. RESULTS: Static compression yield loads ranged from 217.1 to 388.0 N and yield stiffness from 23.7 to 38.0 N/mm. Cycles to failure ranged from 42 x 10(3) to 4,719 x 10(3) at 75% of static ultimate load. There were significant differences between designs in all modes of testing. Failure occurred at the multiaxial link in static and cyclical compression. CONCLUSIONS: Bending yield strengths just exceeded loads expected in vivo. Multiaxial designs had lower static bending yield strength than fixed screw designs. Five out of six multiaxial screw designs achieved one million cycles at 200 N in compression bending. "Ball-in-cup" multiaxial locking mechanisms were vulnerable to fatigue failure. Smooth surfaces and thicker material appeared to be protective against fatigue failure.

Bone Screws↗

Adhesion formation after flexor tendon repair: a histologic and biomechanical comparison of 2- and 4-strand repairs in a chicken model.

PURPOSE: Both increased handling and increased bulk at the repair site have been hypothesized as affecting adhesion formation and gliding after tendon repair. Tendons repaired with 2- and 4-strand techniques were compared using both biomechanical and histopathologic measurements to determine the influence of increasing strand number on adhesion formation and gliding. METHODS: The flexor digitorum profundus tendon of the right middle toe of 80 broiler chickens was cut and then repaired with either a single (2-strand) or double (4-strand) modified Kessler core suture, followed by a running epitendinous suture. The limb was immobilized after surgery. Birds were killed at either 3 days or 4 weeks after tendon repair and adhesion formation measured using either biomechanical testing or quantitative and qualitative histology. For biomechanical testing, the tendon was pulled free of the sheath and a force versus displacement curve was generated. Comparisons of peak force and work to peak were made. Histologic specimens were examined by a pathologist blinded to the treatment group who scored the length and density of adhesions and made qualitative observations. RESULTS: Both biomechanical and histologic data showed expected differences in adhesion formation for early (3 days) and late (4 weeks) healing but no significant differences between 2- and 4-strand repairs. Biomechanical testing of 4-week specimens showed a nonsignificant tendency toward greater work required to break adhesions in 4-strand repairs. CONCLUSIONS: Adhesion formation and gliding resistance of tendons after 2- or 4-strand modified Kessler core suture were not significantly different, which suggests that simply increasing the number of strands crossing a repair does not necessarily result in more adhesions or resistance in this model.

Animals↗

Optimizing biomechanical performance of the 4-strand cruciate flexor tendon repair.

PURPOSE: The purpose of this study was to determine whether increasing the size of the locking loop increased the repair strength of the cruciate 4-strand suture technique and to quantify the biomechanical properties that various peripheral suture techniques provide in the cruciate 4-strand suture technique. METHODS: Fifty-six deep flexor tendons harvested from adult sheep hind limbs were divided randomly into 7 groups of 8. Four groups were repaired using the cruciate core technique without a peripheral suture. The locking loops were set using 10%, 25%, 33%, or 50% of the tendon width and loaded to failure using a distraction rate of 20 mm/min. The 3 groups of tendons then were repaired by using the established optimal locking loop size. These 3 groups were combined with a simple running, cross-stitch, or the interlocking horizontal mattress (IHM) peripheral suture. Repairs were tested to failure and the load at a 2-mm gap, load at failure, and stiffness were determined for all samples. RESULTS: Repairs with locking loops of 25% had the greatest biomechanical properties with load to 2-mm gap formation, load to failure, and stiffness of 10 N, 46.3 N, and 3.9 N/mm, respectively. Those with 33%, 50%, and 10% locking loops followed. Repairs with 10% locking loops failed owing to the suture cut out of the tendon. All other groups failed because of suture breakage. By using the cruciate core technique with a 25% locking loop the IHM/cruciate combination was markedly better than both the cross-stitch/cruciate and simple running/cruciate combinations. CONCLUSIONS: The ideal-sized bite of the locking loops for the cruciate repair is 25% of the tendon's width. Peripheral sutures are vital to the biomechanical properties of the repair. The IHM peripheral suture technique provided the greatest improvement in biomechanical properties.

Animals↗

The role of bone morphogenetic proteins BMP-2 and BMP-4 and their related postreceptor signaling system (Smads) in distraction osteogenesis of the mandible.

Distraction osteogenesis has become a widely used clinical approach in the treatment of craniofacial and orthopedic disorders. The exact biological mechanism of bone formation remains illusive, however. The aim of this study was to evaluate the role of bone morphogenetic protein-2, bone morphogenetic protein-4, and transforming growth factor-beta superfamily-related postreceptor signaling glycoproteins Smads 1 through 5 in distraction osteogenesis. Twelve sheep randomly divided into two groups were distracted to 24 mm at 1 or 4 mm/d using a submandibular osteotomy and an external distractor. After a 5-week fixation period, the mandibles were harvested. Employing immunohistochemical techniques, the sections were investigated for the previous antigens. Osteoblasts and periosteal lining cells were strongly positive. The matrix did not stain for the antigens investigated. Osteocytes demonstrated weak staining for the antigens. No significant difference between the groups was noted. In fracture healing, bone morphogenetic proteins 2 and 4 have been localized to the cambial layer of the periosteum, where healing occurs by intramembranous ossification. Their diffuse staining of the osteoblasts in the distracted region supports a similar role in distraction osteogenesis, where bone formation is predominantly through intramembranous ossification. Furthermore, bone morphogenetic proteins 2 and 4 have been demonstrated to promote mesenchymal cell conversion to osteoblasts. This is similar to the process observed in distraction osteogenesis. The presence of related Smads confirms postreceptor activity of these bone morphogenetic proteins in the process of distraction osteogenesis. This study supports induction of bone morphogenetic proteins 2 and 4, their related postreceptor signaling system (Smads), and intramembranous bone formation associated with mechanical strain in distraction osteogenesis.

Animals↗

Mechanical response of ankle ligaments at low loads.

BACKGROUND: The aim of this study was to examine the mechanical behavior of human ankle ligaments at low forces. Predominantly, ankle ligaments have been studied under the auspices of ligament injury. While the mechanical properties of a ligament when tested to failure provide a basis for comparisons, the loads and displacement do not reflect normal physiologic loading. METHODS: Eight fresh-frozen ankles (mean age 65) were dissected to expose the ligaments surrounding the talocrural joint. Eight ankle ligaments were studied and included: medially-anterior tibiotalar (ATTL), posterior tibiotalar (PTTL), tibiocalcaneal (TCL); laterally-anterior tibiofibular (ATiFL), posterior tibiofibular (PTiFL), anterior talofibular (ATFL), posterior talofibular (PTFL), and calcaneofibular (CFL). Stress relaxation tests were carried out at 30% and 10% strain. The peak load and area under the curve were assessed for all experiments. RESULTS: Significant differences were found for the average peak loads of the elastic response between 30% and 10% strain for each ligament (p < .05). At 10% strain the relationship between the ligaments on the medial and lateral side revealed a Pearson R value of .991 (p = .087). No significant difference was found between the strain energies of the various ligaments (p > .05). The anterior talofibular ligament was found to possess similar relaxation results to the medial ligaments. The calcaneofibular ligament relaxed up to 10% more compared to the anterior talofibular for the same relaxation period. The mechanical testing was performed in uniaxial tension and did not consider off-axis loading that may occur in vivo during ankle motion. CONCLUSIONS: The stress relaxation experiments revealed all ligaments to relax even when loaded to less than 5 N, reflecting the viscoelastic nature of ligaments. The stress relaxation results show that the anterior talofibular ligament does not relax to the same extent as the other lateral ligaments. Examining the properties of human ankle ligaments at low loads has revealed some new findings. CLINICAL RELEVANCE: This study highlights the need to understand the synergistic effects of the ligaments. This is important for reconstruction and arthroplasty procedures.

Aged↗

Biomechanical properties of four circumferential flexor tendon suture techniques.

PURPOSE: We introduce 2 interlocking circumferential flexor tendon suture techniques: the interlocking cross-stitch and the interlocking horizontal mattress repair and biomechanically tested them against 2 commonly used methods. METHODS: Thirty-two deep digital flexor tendons harvested from sheep hindlimbs were transected sharply. These were repaired without a core suture using 4 different circumferential repair techniques: group 1, simple running; group 2, cross-stitch; group 3, interlocking cross-stitch; group 4, interlocking horizontal mattress. All tendons were tested to failure at a distraction rate of 20 mm/min. Load to 2-mm gap formation, stiffness, load to failure, and method of failure all were assessed. RESULTS: The mean load to 2-mm gap formation was 22.8, 20.7, 20.0, and 26.1 N for groups 1, 2, 3, and 4, respectively. The mean stiffness was 7.6, 8.1, 8.7, and 10.1 N/mm, and the mean load to failure was 30.9, 42.1, 49, and 52.9 N for groups 1, 2, 3, and 4, respectively. There was no statistically significant difference between groups 2 and 3. Group 4, however, was statistically better than the others in all measured parameters (except group 3 in load to failure). CONCLUSIONS: The interlocking horizontal mattress was the best performer overall, with statistically greater loads to failure, 2-mm gap formation, and stiffness. This technique could be considered for use in any patient likely to begin an early postoperative finger mobilization program.

Animals↗

Use of a polymeric device to deliver growth factors to a healing fracture.

BACKGROUND: Fracture healing is a cascade of events regulated by systemic and local factors. Local growth factors are believed to play an integral role. The present study evaluates the effects of basic fibroblast growth factor (bFGF) and insulin-like growth factor-1 (IGF-1) using a controlled delivery system in a closed rodent femoral fracture model. METHODS: Female Wistar rats (n = 144) were used in the present study. Animals were randomly allocated to six groups, with each group divided into three time-points of 2, 4 and 8 weeks. Two groups had growth factor administered. The others had no operation or sham operations. Growth factors were delivered to the fracture site using a specialised delivery system. This consisted of a Kirschner-wire coated with ethylene vinyl acetate co-polymer embedded with growth factors, inserted as an intramedullary nail. Fractures were effected with a three-point bending device. Femurs were tested in four-point bending and structural properties of peak load and stiffness were obtained from the load-displacement graphs. Specimens were prepared for qualitative analysis under a light microscope and using immunohistochemistry, specimens were analysed for expression of bFGF, IGF-1 and transforming growth factor beta (TGF-beta). RESULTS: The growth factor-treated groups exhibited larger calluses at 2 and 4 weeks. Four-point bending showed weaker structural properties (stiffness and peak load) at 4 weeks in both growth factor-treated groups. Administration of bFGF or IGF-1 increased the ratio of cartilaginous to mesenchymal tissues in the fracture callus compared with non-treated animals at 2 and 4 weeks. Immunostaining intensity and distribution of both growth factors in the treated groups was greater than the non-treated groups. CONCLUSION: Exogenous delivery of bFGF or IGF-1 alters the course of fracture healing.

Animals↗

Biomechanical analysis of five fixation techniques used in glenohumeral arthrodesis.

BACKGROUND: The purpose of the present study is to compare five fixation techniques in shoulder fusion. The most common complications resulting from shoulder fusion, non-union and unacceptable arm position, might reflect a failure to achieve rigid fixation during the surgical procedure. METHODS: Twenty-five shoulder fusions were carried out on human cadaveric specimens using the following techniques: screw fixation, external fixation, external fixation supplemented with screw fixation, single plate fixation and double plate fixation. Each specimen was tested on a servohydraulic machine to determine stiffness. RESULTS: There was a statistically significant difference in bending and torsional stiffness between all five fixation techniques. Normalized bending (B) and torsional stiffness (T), in descending order, were: double plate (B = 1.00, T = 1.00), single plate (B = 0.77, T = 0.89), external fixation with screws (B = 0.68, T = 0.74), external fixation alone (B = 0.40, T = 0.53), and screws alone (B = 0.13, T = 0.26). CONCLUSION: The risk of the most common complications resulting from shoulder fusion might be minimized if these biomechanical findings are applied to surgical decision making.

Aged↗