Retrospective analysis of mode survival, reliability of atrial sensing and incidence of atrial tachyarrhythmias in 307 single-lead VDD pacemaker patients.

AIMS: The aim of this retrospective analysis was to investigate VDD mode survival, development of atrial tachyarrhythmias (AT), and long-term atrial sensing performance of VDD pacing systems. METHODS AND RESULTS: We implanted single-lead VDD pacemakers in patients with isolated atrioventricular block and performed a retrospective analysis of 307 patients who had their devices implanted between May 1994 and September 2001. In 39 patients (12.7%), the pacing mode had to be reprogrammed to a single-chamber ventricular pacing mode, mostly due to permanent AT. In 16 of these patients, the atrial sensing safety margin was less than 150%. The atrial sensing safety margin was insufficient, i.e. less than 100% in only seven patients. Although only 12 (3.9%) of the patients had a history of paroxysmal AT at the time of pacemaker implantation, 200 (65%) patients presented with AT during follow-up. The mean AT burden at the last follow-up was 2.5%. CONCLUSION: These data illustrate that single-lead VDD pacemakers can be applied without serious complications in a highly selected group of patients. Our main concern is the development of AT in a large part of our population. Over a 10-year period, two thirds of our patients presented with AT.

Aged↗

Form analysis using digital signal processing reliably discriminates far-field R waves from P waves.

The correct detection of atrial arrhythmias by pacemakers is often limited by the presence of far-field R waves (FFRWs) in the atrial electrogram. Digital signal processing (DSP) of intracardiac signals is assumed to provide improved discrimination between P waves and FFRWs when compared to current methods. For this purpose, 100 bipolar and unipolar intracardiac atrial recordings from 31 patients were collected during pacemaker replacement and used for the off-line application of a novel DSP algorithm. Digital processing of the atrial intracardiac electrogram (IEGM) signals (8 bit, 800 samples/s) included filtering and calculation of the maximum amplitude and slope of the detected events. The form parameter was calculated, being the sum of the most negative value of the amplitude and that of the slope of the detected event. The algorithm collects form parameter data of P waves and FFRWs and composes histograms of these data. A sufficiently large gap between the FFRW and P wave histograms allows discrimination of these two signals based on form parameters. Three independent observers reviewed the reliability of classification with this algorithm. Sensitivity and specificity of FFRW detection were 99.63% and 100%, respectively, and no P waves were falsely classified. It can be concluded that this novel DSP algorithm shows excellent discrimination of FFRWs under off-line conditions and justify the implementation of this algorithm in future pacemakers for real-time discrimination between P waves and FFRWs. This method prevents false mode switching and allows correct and immediate intervention pacing for atrial tachyarrhythmias.

Algorithms↗