Arterial pressure transfer characteristics: effects of travel time.

We investigated the quantitative contribution of all local conduit arterial, blood, and distal load properties to the pressure transfer function from brachial artery to aorta. The model was based on anatomical data, Young's modulus, wall viscosity, blood viscosity, and blood density. A three-element windkessel represented the distal arterial tree. Sensitivity analysis was performed in terms of frequency and magnitude of the peak of the transfer function and in terms of systolic, diastolic, and pulse pressure in the aorta. The root mean square error (RMSE) described the accuracy in wave-shape prediction. The percent change of these variables for a 25% alteration of each of the model parameters was calculated. Vessel length and diameter are found to be the most important parameters determining pressure transfer. Systolic and diastolic pressure changed <3% and RMSE <1.8 mmHg for a 25% change in vessel length and diameter. To investigate how arterial tapering influences the pressure transfer, a single uniform lossless tube was modeled. This simplification introduced only small errors in systolic and diastolic pressures (1% and 0%, respectively), and wave shape was less well described (RMSE, approximately 2.1 mmHg). Local (arm) vasodilation affects the transfer function little, because it has limited effect on the reflection coefficient. Since vessel length and diameter translate into travel time, this parameter can describe the transfer accurately. We suggest that with a, preferably, noninvasively measured travel time, an accurate individualized description of pressure transfer can be obtained.

Aorta↗

Changes in finger-aorta pressure transfer function during and after exercise.

Noninvasive finger blood pressure has become a surrogate for central blood pressure under widely varying circumstances. We tested the validity of finger-aorta transfer functions (TF) to reconstruct aortic pressure in seven cardiac patients before, during, and after incremental bicycle exercise. The autoregressive exogenous model method was used for calculating finger-aorta TFs. Finger pressure was measured noninvasively using Finapres and aortic pressure using a catheter-tip manometer. When applying the individual TFs found during rest for reconstruction of aortic pressure during all workloads, systolic pressure was increasingly underestimated, with large variation between subjects: +4.0 to -18.1 mmHg. In most subjects, diastolic pressure was overestimated: -3.9 to +5.5 mmHg. Pulse pressure estimation varied between +4.5 and -21.9 mmHg. In all cases, wave distortion was present. Postexercise, error in reconstructed aortic systolic pressure slowly declined, and diastolic pressure was overestimated. During rest, the TF gain had a minimum between 3.65 and 4.85 Hz (Fmin). During exercise, Fmin shifted to frequencies between 4.95 and 7.15 Hz at the maximum workload, with no change in gain. Postexercise, gain in most subjects shifted to values closer to unity, whereas Fmin did not return to resting values. Within each subject, aorta-Finapres travel time was linearly related to mean pressure. During exercise, Fmin was linearly related to both delay and heart rate. We conclude that, during increasing exercise, rest TFs give an increasingly unreliable reconstruction of aortic pressure, especially at higher heart rates.

Adult↗

Time-domain cross-correlation baroreflex sensitivity: performance on the EUROBAVAR data set.

OBJECTIVE: To test a new method (cross-correlation baroreflex sensitivity, xBRS) for the computation of time-domain baroreflex sensitivity on spontaneous blood pressure and heart interval variability using the EUROBAVAR data set. METHODS: We applied xBRS to the 42 records in the EUROBAVAR data set, obtained from 21 patients in the lying and standing positions. One patient had a recent heart transplant and one was diabetic with evident cardiac autonomic neuropathy. xBRS computes the correlation between beat-to-beat systolic blood pressure and R-R interval, resampled at 1 Hz, in a sliding 10 s window, with delays of 0-5 s for interval. The delay with the greatest positive correlation is selected and, when significant at P = 0.01, slope and delay are recorded as one xBRS value. Each 1 s of the recording is the start of a new computation. Non-parametric tests are used. RESULTS: With patients in the lying position, xBRS yielded a value of 12.4 ms/mmHg compared with the EUROBAVAR sequential 16.2 ms/mmHg, and for the standing positions the respective values were 6.2 and 6.7 ms/mmHg, giving lying to standing ratios of 1.96 and 2.10, respectively. xBRS yielded results for all files, with 20 values per minute on average at a lower within-patient variance. Best delays were 0, 1 and 2 s, and the delay increased by 102 ms when the patient was in the standing position. The xBRS method was successful in the patients with diabetes and the heart transplant. CONCLUSION: The xBRS method should be considered for experimental and clinical use, because it yielded values that correlated strongly with and were close to the EUROBAVAR averages, yielded more values per minute, had lower within-patient variance and measured baroreflex delay.

Adult↗

Tilt table design for rapid and sinusoidal posture change with minimal vestibular stimulation.

INTRODUCTION: Cardiovascular response to fast posture change can be used to model individual orthostatic response under normal circumstances and after spaceflight. We set out to construct a computer-controlled tilt table suitable for repeated sinusoidal tilt motion as well as fast, single head-up tilt (HUT). The movement profile of the table was designed to prevent muscle tensing and limit vestibular stimulation. METHODS: On the new table, 20 healthy subjects underwent a protocol of fast HUT and sinusoidal tilt motion at 2.5 tilts per minute. BP was measured non-invasively (Finapres). Time domain dynamic response to HUT and frequency domain response to sinusoidal tilts were derived from the beat-to-beat BP and from interbeat-interval (IBI) series. RESULTS: Tilt motion did not induce dizziness and was experienced by all subjects as smooth. The systolic BP response to fast HUT correlated mildly with the systolic BP spectral power at the sinusoidal tilt frequency (R = 0.47). The IBI response to fast HUT correlated well with the IBI power at the sinusoidal tilt frequency (R = 0.74). DISCUSSION: In this study we presented a computer controlled tilt table capable of fast posture change and sinusoidal tilts. An exploratory protocol demonstrated that the table is suitable for obtaining cardiovascular response to posture change for modeling purposes.

Adult↗