A theoretical basis for parameter selection and instrument design in comprehensive size-exclusion chromatography x liquid chromatography.

A novel approach for the selection of the operational parameters (linear velocity, column length) for a comprehensive 2D-LC system is discussed. Starting point for the calculations is a given second dimension ((2)D) separation and a desired peak capacity for the 2D system. Using the theory developed here the optimum settings for the first dimension ((1)D) column can be derived. Theory clearly indicates that the choice of the (1)D conditions is basically limited to just one set of column lengths and linear velocities. The new method is tested on a comprehensive two-dimensional liquid chromatography system which uses size-exclusion chromatography (SEC) followed by reversed phase liquid chromatography (RPLC). A novel LC/LC interface, using a six-port valve rather than storage loops, joins the two chromatographic dimensions. From a theoretical comparison of continuous low flow and stop-flow operation the latter method was found to be an attractive mode of interfacing. The common idea that stop-flow operation results in additional band broadening is shown to be incorrect. The new interface design operated in the stop-flow mode permits the use of conventional analytical diameter HPLC columns, 7.8mm for SEC and 4.6mm for RPLC. The reversed phase chromatography utilizes a monolithic C-18 modified silica column, which produces fast and efficient analyses. As test samples complex mixtures of peptides were analyzed.

Chromatography, Gel↗

Selection of comparison criteria and experimental conditions to evaluate the kinetic performance of monolithic and packed-bed columns.

The present study concerns the problem of finding appropriate experimental conditions and comparison criteria to assess the kinetic performance of LC supports with different sizes or morphologies. A general procedure, based on evaluating each support for its own optimal mobile-phase composition, is proposed. The practical elaboration of the procedure is illustrated using the specific case of a capillary LC separation of a series of polycyclic aromatic test compounds employing silica-monolith capillary columns and capillary columns packed with 6-microm porous particles. To compare the systems for their ability to yield the fastest critical-pair separation, plate-height measurements are transformed into an effective plate number kinetic plot, i.e., a plot of the extrapolated retention time divided by the square of the extrapolated effective plate number (t(R)/N(eff)(2)) versus N(eff). This type of data representation provides a direct and universal basis to compare the kinetic performance of different LC supports and it corrects for differences in retention strength arising from different phase ratios.

Chromatography, Liquid↗

Recent applications in capillary electrochromatography.

In this review research papers on the application of CEC are summarized that have been published between May 2003 and May 2005. First, a short overview is given of trends and developments in CEC that may increase the applicability of the separation technique. Next, application-oriented research using CEC is described in biochemical studies, including proteomics and genomics, in the analysis of food and natural products, and in pharmaceutical, industrial, and environmental analysis.

Animals↗

Determination of major carotenoids in vegetables by capillary electrochromatography.

A simple and rapid method for the isocratic separation and determination of carotenoids (carotenes and xanthophylls) in vegetables by CEC is described. The capillary column (100 microm ID, 25 cm effective length) was packed with 3 microm Hypersil ODS particles. The optimized mobile phase contained 60% ACN, 35% THF and 5% of a 5 mM Tris aqueous buffer of pH 8. beta-Carotene, lycopene and lutein were separated with efficiencies of 66 000-128 000 plates/m within a short time (less than 12 min for the last peak eluted, 13/13'-cis-beta-carotene). An excellent resolution of the three carotenoids, as well as partial resolution of their geometrical isomers, was achieved. Application to the determination of the analytes in carrot, tomato, spinach and corn was demonstrated.

Carotenoids↗

Performance limits of monolithic and packed capillary columns in high-performance liquid chromatography and capillary electrochromatography.

A method is proposed for the comprehensive characterization and comparison of columns in the high-performance liquid chromatographic (HPLC) and capillary electrochromatographic (CEC) modes. Using this approach, column parameters such as the number of plates, the eddy-diffusion and mass-transfer contributions to peak broadening, the permeability, and the analysis time are incorporated in a single graph and a comparison in terms of efficiency and speed is obtained. The chromatographic performance of silica-based and polymer-based monolithic capillary columns is discussed and a comparison is made with the performance of packed columns. Also, the potential of ultra-high-pressure liquid chromatography is discussed in this context. In the HPLC mode, the best results were obtained with silica monoliths; in the CEC mode, the low-density methacrylate-ester-based monoliths showed the best performance.

Chromatography, High Pressure Liquid↗

Tailoring the morphology of methacrylate ester-based monoliths for optimum efficiency in liquid chromatography.

Methacrylate ester-based monolithic stationary phases were prepared in situ in fused-silica capillaries and simultaneously in vials. The influence of the composition of the polymerization mixture on the morphology was studied with mercury intrusion porosimetry, scanning electron microscopy, and nitrogen adsorption measurements. A high-density porous polymeric material with a unimodal pore-size distribution was prepared with 40 wt % monomers and 60 wt % solvent in the mixture. A low-density material, prepared with a 20:80 ratio of monomers versus pore-forming solvent, showed a bimodal pore-size distribution and a much finer structure than the high-density monolith. The characteristic pore size could be controlled by changing the ratio of pore-forming solvents. With increasing solvent polarity, both the pore size and the dimension of the globules increased. The best efficiency in the CEC mode was obtained with an average pore size of 600 nm. Low-density monoliths exhibited lower A- and C-terms than high-density monoliths. With the optimal monolithic material, a minimum plate height of 5 mum could be obtained. The low-density monolith also performed better in the HPLC mode, giving a minimum plate height of 15 mum and a much higher flow permeability than that of the high-density material.

Journal Article↗

Practical aspects of using methacrylate-ester-based monolithic columns in capillary electrochromatography.

Methacrylate-ester-based monoliths containing quaternary ammonium groups were prepared in situ in capillary columns and in simultaneous experiments in vials, employing thermal initiation. The chromatographic properties of the monoliths were determined with capillary electrochromatography (CEC), and their morphology was studied with mercury-intrusion porosimetry on the bulk materials. Materials with different, well repeatable pore-size distributions could be prepared. A satisfactory column-to-column and run-to-run repeatability was obtained for the electro-osmotic mobility, the retention characteristics (k-values) and the efficiency on the columns prepared and tested in the CEC mode. A relatively high electro-osmotic flow was observed in the direction of the positive electrode. The electro-osmotic mobility was found to be influenced only marginally by mobile-phase parameters such as the pH, ionic strength, and acetonitrile content. The retention behavior of the monolithic columns was similar to that of columns packed with C18-modified silica particles. Columns could be prepared with optimum plate heights ranging from 6 microm for unretained compounds to 20 microm for well retained (k=2.5) polyaromatic hydrocarbons. However, for specific analytes a - still unexplained - lower chromatographic column efficiency was observed.

Chromatography, Micellar Electrokinetic Capillary↗

Studying protein aggregation by programmed flow field-flow fractionation using ceramic hollow fibers.

Ceramic hollow fibers have been used as separation channels for flow field-flow fractionation. The fibers were made of alpha-alumina, with a gamma-alumina layer on the inside wall acting as a semipermeable (ultrafiltration) membrane. The fibers and the separation system were tested by determining the diffusion coefficients of a series of standard proteins under various experimental conditions. Even for the smallest protein studied, a complete recovery from the fiber was obtained. A single fiber could be used for several months without problems such as leakage or fouling. The precision of the diffusion coefficient measurements was in the order of 5-10%. A good agreement with literature data was found. Programming of the cross-flow, with a time-delayed exponential decay program, was applied to extend the accessible size range for the sample components. With flow programming, the observed retention times increased linearly with the logarithm of the molar mass of proteins and aggregates, as predicted by theory. Heat-induced aggregation of beta-lactoglobulin (beta-LG) in aqueous solution was studied with the system. Upon heating, not only the extent of aggregation but also the size of the beta-LG aggregates was found to increase with the original concentration of beta-LG in solution and with the heating time. After heating in the presence of salt, very large aggregates were formed, with molar masses over 100 million. A multiangle light scattering detector was used to estimate molar masses and sizes of the protein aggregates. From the relation between the apparent diffusion coefficients and the molar masses of the aggregates, as well as from the ratio of the rms (scattering) and the hydrodyamic radii, it was concluded that the larger beta-LG aggregates behave as flexible chains in solution.

Ceramics↗

Contactless conductivity detection of synthetic polymers in non-aqueous size-exclusion electrokinetic chromatography.

A capacitively coupled contactless conductivity detection (CCD) system has been applied for the detection of neutral synthetic polymers in capillary size-exclusion electrokinetic chromatography (SEEC). Polystyrene standards, that were used as a model compounds, were separated on a capillary column packed with porous 10 microm silica particles with an electrokinetically driven mobile phase, and detected by CCD and UV detection simultaneously. Mass-calibration curves for polystyrene were constructed. Satisfactory results were obtained for the linearity, the run-to-run repeatability (<0.2% for the relative retention and <4% for the peak area) and the robustness of the detector. One of the major issues in this preliminary study was to investigate the origin of the peaks observed for the polystyrene standards. The effect of the molar mass of the polystyrenes on the sensitivity was small. Therefore, the signals obtained could not be explained as the result of an increased viscosity and a decreased solution conductivity of the solute zone. An alternative hypothesis is suggested, and recommendations for further research are given.

Calibration↗

Band broadening in size-exclusion chromatography of polydisperse samples.

Understanding and controlling the band broadening is essential to obtain accurate molar-mass distributions by size-exclusion chromatography (SEC). In this paper, band broadening in SEC is reviewed from a contemporary perspective. The observed band broadening is due to dispersion inside and outside the chromatographic column (undesirable band broadening) and to the polydispersity of the sample (desirable SEC selectivity). The various contributors to band broadening are discussed. Integrity plots are introduced as a tool to evaluate the performance of specific SEC columns at given experimental conditions. For narrow polymer standards on single SEC columns the observed peak width is dominated by the chromatographic dispersion. MALDI-ToF-MS is demonstrated as an alternative to determine the PDI of narrowly distributed samples. The plate heights encountered at very high reduced velocities are found to be lower than expected. This is advantageous for fast separations by SEC.

Chromatography, Gel↗

Determination of the amylose-amylopectin ratio of starches by iodine-affinity capillary electrophoresis.

This paper describes the application of capillary electrophoresis to separate and quantify the main polysaccharide components, amylose and amylopectin, present in starch samples. The separation is based on the well-known affinity of these compounds to iodine. The starch components could be effectively separated in less than 7 min using an uncoated fused-silica 'bubble cell' capillary. The proposed method has been applied for the quantitative determination of the soluble amylose content and the ratio amylose-amylopectin in commercial starches. It is shown that the present method is reliable, gives detection limits in the order of 0.1 mg mL(-1), is faster than other methodologies reported in the literature, and can be easily applied to the analysis of different starches. In spite of differences in solubility of amylopectin from different sources, a reasonable estimate of the amylose-amylopectin ratio could be made. Additionally, it was shown that the resulting profiles obtained after hydrolysis with isoamylase and alpha-amylase can provide information on the structure of the starches studied.

Amylopectin↗

Characterization of glycerin-based polyols by capillary electrophoresis.

Methods based on capillary electrophoresis (CE) have been developed to obtain the molar mass distribution (MMD) of glycerin-based polyols and details on the presence of mono- and difunctional byproducts in technical samples. Prior to the analyses the hydroxy end-groups of the trifunctional polyols were converted to chargeable and UV-active moieties with phthalic anhydride (PhAH) as the derivatization reagent. With a method of capillary zone electrophoresis (CZE) samples of glycerin-based polyols with average molar masses up to 6000 were separated according to their charge-to-size ratio. The separations were carried out with a buffer solution containing 50% (v/v) acetonitrile and 10 mM sodium tetraborate, and for detection UV absorption at 220 nm was measured. An approximately linear relation between the reciprocal of the effective mobilities and the degree of polymerisation of the glycerin-based polyols was found. Therefore, the proposed CZE system could be used to determine the degree of polymerisation and polydispersity of technical glycerin-based polyol samples. The effect of the presence of sodium dodecyl sulfate (SDS) in the buffer solution on the CE separation of linear polyethylene glycols (PEGs), polypropylene glycols (PPGs) and ethylene oxide-propylene oxide (EO-PO) copolymers with different molar masses was investigated. The interaction between the charged polymer derivatives and SDS ions in solution increased strongly with the degree of polymerisation and the amount PO in the chain of the polymeric compounds. This behaviour made it possible to invert the migration order of EO-PO containing polymers of different size. With a background electrolyte (BGE) composition of 10mM SDS and 25% (v/v) acetonitrile in borate buffer mono- and difunctional byproducts were separated from the main glycerin-based polyols based on their number of end-groups. Accurate quantities for the mono- and difunctional impurities in technical glycerin-based polyol products were determined.

Electrophoresis, Capillary↗

Determination of the degree of substitution and its distribution of carboxymethylcelluloses by capillary zone electrophoresis.

A method based on capillary zone electrophoresis (CZE) has been developed to determine the degree of substitution (DS) of carboxymethylcellulose (CMC). Separations were performed with borate buffer (pH 9, ionic strength 20 mM) as background electrolyte in capillaries of 75 microm ID, with an applied voltage of 10 kV, and for detection UV absorption at 196 nm was measured. The use of an internal standard (phthalic acid) to correct for mobility variations resulted in a strong improvement of the precision of the DS determination. Experiments with indirect UV detection indicated that the peak widths obtained actually reflect the variation in mobility, and with that of the DS value, of CMC samples. With the proposed method not only the average DS value but also its dispersity could be established for technical CMC samples. A small but definite effect of the polymeric size on the mobilities was observed. Therefore, DS calibration curves will have to be determined for a specific MM range. Since the size effect is small, a classification of CMCs as low-, middle-, or high MM will be sufficient to obtain accurate data on the DS distribution.

Carboxymethylcellulose Sodium↗

Capillary electrochromatography in the size-exclusion mode.

In this review the literature on the application of capillary electrochromatography (CEC) for size-based separations of macromolecules is summarized. Opportunities and limitations of CEC specially related to the size-exclusion mode (SEEC) are indicated. Applications with synthetic polymer samples as well as with biomacromolecules (polysaccharides, proteins) are shown. The prospects for a further development and application of SEEC are discussed.

Chromatography, Micellar Electrokinetic Capillary↗

Study of the influence of the aspect ratio on efficiency, flow resistance and retention factors of packed capillary columns in pressure- and electrically-driven liquid chromatography.

The influence of the aspect ratio, rho (rho = column diameter/particle diameter), on column parameters such as efficiency, retention factors and flow resistance was studied in both high-performance liquid chromatography and capillary electrochromatography with packed capillary columns. In order to compare the true efficiencies of different columns, a procedure to account for external band broadening was applied. High efficiencies (reduced plate height h approximately 2) were obtained with capillary columns with internal diameters of 150-, 100-, and 75-microm, packed with 10-microm particles. In contrast to previous reports in the literature, no significant improvements in efficiency or flow resistance were observed when the aspect ratio of such columns was decreased. Our observations suggest that the wall effect in these types of columns is not significant. When the aspect ratio was decreased by increasing the particle size, a decrease in reduced plate height was observed. However, the results of flow resistance measurements showed that the latter effect should be attributed to differences in packing and particle batch quality rather than to differences in the aspect ratio.

Chromatography, High Pressure Liquid↗

Performance optimization of spectroscopic process analyzers.

To increase the power and the robustness of spectroscopic process analyzers, methods are needed that suppress the spectral variation that is not related to the property of interest in the process stream. An approach for the selection of a suitable method is presented. The approach uses the net analyte signal (NAS) to analyze the situation and to select methods to suppress the nonrelevant spectral variation. The empirically determined signal-to-noise of the NAS is used as a figure of merit. The advantages of the approach are (i). that the error of the reference method does not affect method selection and (ii). that only a few spectral measurements are needed. A diagnostic plot is proposed that guides the user in the evaluation of the particular suppression method. As an example, NIR spectroscopic monitoring of a mol-sieve separation process is used.

Journal Article↗

Comparison of the efficiency of microparticulate and monolithic capillary columns.

A comparison is made between the efficiency of microparticulate capillary columns and silica and polymer-based monolithic capillary columns in the pressure-driven (high-performance liquid chromatography) and electro-driven (capillary electrochromatography) modes. With packed capillary columns similar plate heights are possible as with conventional packed columns. However, a large variation is observed in the plate heights for individual columns. This can only be explained by differences in the quality of the packed bed. The minimum plate height obtained with silica monolithic capillary columns in the HPLC mode is approximately 10 microm, which is comparable to that of columns packed with 5-microm particles. The permeability of wide-pore silica monoliths was found to be much higher than that of comparable microparticulate columns, which leads to much lower pressure drops for the same eluent at the same linear mobile phase velocity. For polymer-based monolithic columns (acrylamide, styrene/divinyl benzene, methacrylate, acrylate) high efficiencies have been found in the CEC mode with minimum plate heights between 2 and 10 microm. However, in the HPLC mode minimum plate heights in the range of 10 to 25 microm have been reported.

Chromatography, High Pressure Liquid↗

Recent applications in capillary electrochromatography.

The most recent and important applications in capillary electrochromatography (CEC) are summarized, covering literature published since May 2001. A selection of new developments in stationary phases for CEC is highlighted, and enantiomeric separations and chiral stationary phases are discussed. Also, CEC applications of biological molecules, pharmaceuticals, and applications in the field of industrial and environmental analysis are summarized. For this review three modes of CEC were taken into account, i.e., packed-column CEC, CEC using monolith technology, and open-tubular CEC.