PubMed Health⌕ Search

Biomedical subjects

Winfried A Willinek

Publications and source records attributed to Winfried A Willinek.

14 recordsLinked to original sources

Intra-individual comparison of image contrast in SPIO-enhanced liver MRI at 1.5T and 3.0T.

The purpose of the study was to examine if the higher susceptibility at 3.0 Tesla (T) compared to 1.5 T will affect the contrast in MR imaging of the liver after application of superparamagnetic iron oxide particles (SPIO). The study was approved by our institutional review board and informed consent was obtained. Seventeen healthy volunteers were examined in a prospective, intra-individual comparative study within one day on a 1.5 T and a 3.0 T MRI system. T2 weighted TSE sequences were acquired after bolus injection of a SPIO contrast agent. Image contrast and signal to noise ratio (SNR) were compared between the field strengths. Image contrast was calculated between the liver tissue and the kidneys / spleen / muscles and fluids. The students'T-test was used for statistical analysis. No influence of the higher field strength could be observed on image contrast except for the liver / muscle contrast. This was due to a distinct SNR increase of the muscle tissue at 3.0 T as a result of their relaxation properties. The higher susceptibility at 3.0 T compared to 1.5 T does not translate into a stronger signal attenuation of the SPIO enhanced liver parenchyma.

Adult↗

High spatial resolution contrast-enhanced MR angiography of the supraaortic arteries using the quadrature body coil at 3.0T: a feasibility study.

To examine whether the the increased signal-to-noise (S/N) available at 3.0T would permit the use of the quadrature body coil for high spatial resolution contrast-enhanced (CE) MR angiography (MRA), and whether the large FOV that was used in our routine 1.5T protocol would also be feasible at 3.0T. In a prospective study, 43 patients and five volunteers were examined on a clinical whole-body 3.0T MR unit (Intera, Philips Medical Systems, Best, The Netherlands) after institutional review board approval and informed consent. Three-dimensional CE MRA (T1 gradient echo-sequence with TR/TE = 5.7/1.93 msec.; acquisition time, 1:54 min.) using randomly segmented central k-space ordering (CENTRA) was acquired with the quadrature body coil, using over a FOV of 350 mm. A high-image matrix of 432x432 yielded a non-zero filled voxel size of 0.81 mm x 0.81 mm x 1.0 mm (0.66 mm(3)). For quantitative analysis, contrast ratios (CR) between vessels (S) and signal in surrounding tissue (ST) were calculated [(S-ST)/(S+ST)]. For qualitative analysis, image quality and presence of artifacts were rated by two radiologists in consensus on a five-point scale (1=excellent to 5=nondiagnostic). Digital subtraction angiography (DSA) served as the standard of reference in patients with vascular disease. In the five volunteers, 1.5T CE MRA using a phased array neurovascular coil was available for intraindividual comparison. 3.0T CE MRA was successfully performed in 48/48 subjects (100%). Mean CR+/- SD were 0.76 (139.30/182.42) and 0.87 (235.18/270.14) at 3.0T and 1.5T respectively . Mean image quality was 3.82+/-0.86. Intraindividual comparison between 1.5T and 3.0T CE MRA in the volunteers revealed no significant difference in image quality (4.2+/-0.74 vs 4.6+/-0.80; p>0.05). Vascular disease was correctly identified in 13/13 patients with DSA correlation. CE MRA of the supraaortic arteries is feasible at 3.0T using a large FOV of 350 mm. The signal gain at 3.0T enables high spatial resolution contrast-enhanced MR angiography by using the built-in quadrature body coil only.

Adult↗

High-field-strength MR imaging of the liver at 3.0 T: intraindividual comparative study with MR imaging at 1.5 T.

PURPOSE: To prospectively evaluate whether magnetic resonance (MR) imaging of the liver at 3.0 T is comparable to that at 1.5 T with respect to image artifacts, image quality, and diagnostic utility in terms of detection and characterization of focal liver lesions in patients with these lesions. MATERIALS AND METHODS: Patients provided informed consent after the study had been explained, and the institutional review board approved the study protocol. An intraindividual comparative study was performed in 21 patients (12 men and nine women; mean age, 58.7 years; range, 36-76 years) with a total of 79 focal liver lesions (benign and malignant) who were examined at 1.5- and 3.0-T MR imaging within 1 week. The imaging protocol consisted of T2-weighted turbo spin-echo (SE) sequences with or without fat suppression, as well as T1-weighted gradient-echo (GRE) sequences with or without gadolinium-based contrast agent. All images were rated independently by two radiologists with respect to types of artifacts (susceptibility, motion, pulsation, image homogeneity, and electrodynamic effects) and in regard to detectability and characterization of focal liver lesions. A modified sign test was used for statistical analysis (alpha < .2). RESULTS: Motion artifacts were significantly more pronounced in non-fat-suppressed T2-weighted turbo SE images at 3.0 T (P = .03), whereas pulsation artifacts were more pronounced (P = .19) in precontrast T1-weighted GRE 1.5-T images. No statistically significant differences (P < .2) were observed for the remaining artifacts and sequences. Of the 79 index lesions, a total of 76 were prospectively identified at 1.5-T imaging and a total of 77 were identified at 3.0-T imaging. CONCLUSION: MR imaging of the liver at 3.0 T, compared with that at 1.5 T, is feasible with equivalent image quality and diagnostic utility in terms of detection and characterization of focal liver lesions.

Adult↗

3.0 T neuroimaging: technical considerations and clinical applications.

Since approval by the US Food and Drug Administration (FDA) in 2000, human MR imaging at field strength up to 4.0 T in clinical practice and up to 8.0 T on research systems has become available. Although human MR imaging at field strengths greater than 1.5 T was performed even before 1999 on research systems, the FDA approval for clinical use and the advent of actively shielded magnets marked a new trend for MR vendors and users. Because of the potential technical benefits when moving from 1.5 T to 3.0 T, the number of 3.0 T installations is increasing continuously worldwide. This article reviews the benefits, challenges, and the current knowledge of 3.0 T whole body MR imaging and summarizes its clinical applications.

Adult↗

Brain tumors: full- and half-dose contrast-enhanced MR imaging at 3.0 T compared with 1.5 T--Initial Experience.

PURPOSE: To prospectively and intraindividually compare the effect of magnetic resonance (MR) imaging at a higher magnetic field strength (3.0 T) on contrast-to-noise ratio (CNR) at different doses of a T1-shortening contrast agent in patients with contrast-enhancing brain lesions, with 1.5-T MR imaging as a reference standard. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained for all patient and volunteer studies. Twelve patients (six women, six men; mean age, 58 years; range, 29-76 years) with 12 enhancing brain lesions (11 patients with primary brain tumors and one with a solitary cerebral metastasis) underwent contrast material-enhanced MR imaging three times, on three separate days: once at 1.5 T with a full dose of 0.10 mmol/kg gadopentetate dimeglumine, once at 3.0 T with a full dose, and once at 3.0 T with half that dose, 0.05 mmol/kg. The same contrast-enhanced T1-weighted spin-echo images (repetition time msec/echo time msec, 500/12; section thickness, 5 mm; matrix, 256 x 205) were obtained at both 3.0 T and 1.5 T after prior optimization of parameters at 3.0 T. The number and conspicuity of enhancing brain lesions were assessed with blinded clinical image reading. Signal-to-noise ratio and CNR were determined with region of interest analysis of enhancing lesions and normal contralateral white matter. For 3.0 T with half the standard dose and with the full dose, CNR of lesions was intraindividually compared with CNR at 1.5 T with the full dose by using the Wilcoxon matched-pairs signed rank test. RESULTS: At 3.0 T and full dose, CNR was 2.8-fold higher than that at 1.5 T and full dose (P < .001). At the same time, higher lesion conspicuity at clinical image reading was observed. With only half the standard dose, MR imaging at 3.0 T still yielded higher CNR (1.3-fold higher) than that with full dose at 1.5 T (P < .01). CONCLUSION: With the same amount of contrast agent, MR imaging at 3.0 T offered a significantly higher CNR of enhancing cerebral lesions, compared with that at 1.5 T; even with the dose reduced by half, CNR was still higher at 3.0 T.

Adult↗

Coronary MR angiography at 3.0 T versus that at 1.5 T: initial results in patients suspected of having coronary artery disease.

PURPOSE: To prospectively evaluate the feasibility, image quality, and accuracy of coronary magnetic resonance (MR) angiography at 3.0 T in patients suspected of having coronary artery disease and to prospectively compare these results with those of coronary MR angiography performed at 1.5 T. MATERIALS AND METHODS: The study was approved by the institutional review board, and informed consent was obtained from all patients. Eighteen patients (11 men, seven women; mean age, 63 years; age range, 45-76 years) suspected of having coronary artery disease who were scheduled to undergo elective conventional coronary angiography (reference standard) were included. For coronary MR angiography at 3.0 and 1.5 T, a vector electrocardiographically gated three-dimensional segmented k-space gradient-echo imaging sequence was combined with real-time respiratory navigator gating and tracking. Signal-to-noise ratios (SNRs), contrast-to-noise ratios (CNRs), scores of image quality and sensitivity and specificity for the detection of coronary artery stenosis on a segment-by-segment basis were assessed at 3.0 and 1.5 T. Data were analyzed for statistical differences by using the Wilcoxon matched-pairs test and the McNemar test. RESULTS: The average increase in SNR at 3.0 T with respect to that at 1.5 T was 29.5% for the left coronary artery (LCA) and 31.2% for the right coronary artery (RCA) (P < .001), and the average increase in CNR was 21.8% for the LCA and 23.5% for the RCA (P < .001). Scores of image quality (P = .77) and diagnostic accuracy for the detection of coronary artery stenoses (sensitivity and specificity: 82% and 89%, respectively, at 3.0 T vs 82% and 88% at 1.5 T; P > .99) were identical or almost identical at both field strengths. CONCLUSION: Coronary MR angiography at 3.0 T is feasible in patients suspected of having coronary artery disease and yields significant increases in SNR and CNR, although current techniques do not result in significantly improved image quality and diagnostic accuracy compared with the quality and accuracy at 1.5 T. (c) RSNA, 2005.

Aged↗

Sensitivity encoding (SENSE) for contrast-enhanced 3D MR angiography of the abdominal arteries.

PURPOSE: To assess sensitivity encoding (SENSE) for contrast-enhanced MR angiography (CE-MRA) of the abdominal arteries in comparison with standard MRA protocols. MATERIALS AND METHODS: In 22 patients MRA of the abdominal arteries was performed twice (once using a standard protocol, and once with the additional use of SENSE). In 10 patients all examination parameters were kept constant (TR/TE/FA = 3.8 msec/1.3 msec/30 degrees ), and a reduction in scan time from 22 to 11 seconds was realized with the use of SENSE. In 12 patients, using SENSE the acquisition matrix was increased from 208 to 416, keeping the scan time constant. Image quality was scored on a five-point scale by three radiologists. Additionally, ROI-based measurements of CNR were performed. RESULTS: For both protocols, image quality was significantly improved using SENSE. The time-reducing SENSE protocol yielded an average score of 4.2 points vs. 3.1 for the standard protocol. Using SENSE to increase the acquisition matrix, an average score of 4.3 was reached vs. 3.2 for the standard protocol (P < 0.05). The number of depictable small vessels and their bifurcations was significantly increased by either of the two SENSE protocols as compared to the standard imaging procedure. CONCLUSION: SENSE for MRA of the abdominal arteries significantly increases image quality and permits a substantial reduction in breath-hold time or a significantly improved spatial resolution.

Abdomen↗

Perforating colonic duplication as rare cause of renal abscess in children.

Renal abscess is uncommon in children. In a few cases, ascending infection and/or hematogenous spread have been outlined as pathophysiologic mechanisms in published studies. We report on a 7-month-old female infant who was hospitalized with a high fever. Ultrasonography revealed a hypoechogenic mass in the left kidney. The diagnosis of a renal abscess was confirmed by computed tomography. Because antibiotic treatment had only a transient effect, an open operative procedure was performed. Intraoperatively, a perforating colonic duplication with broad contact to the kidney was found that had destroyed major parts of the kidney's parenchyma. After nephrectomy and complete resection of the colonic duplication, the patient recovered uneventfully.

Abdominal Abscess↗

Noninvasive detection of steno-occlusive disease of the supra-aortic arteries with three-dimensional contrast-enhanced magnetic resonance angiography: a prospective, intra-individual comparative analysis with digital subtraction angiography.

BACKGROUND AND PURPOSE: Concomitant disease of the supra-aortic arteries can influence the outcome of surgical treatment of carotid artery stenosis. However, sensitivity and specificity data of noninvasive contrast-enhanced 3-dimensional (3D) magnetic resonance angiography (CE MRA) for the detection of steno-occlusive disease of the entire supra-aortic arteries including the circle of Willis remain unclear. We aimed to intra-individually compare high-spatial-resolution CE 3D MRA and digital subtraction angiography (DSA) for the assessment of steno-occlusive vascular disease of the supra-aortic arteries. METHODS: CE MRA and DSA of the supra-aortic arteries were prospectively performed in 50 consecutive patients. Intra-individual comparison of CE MRA and DSA was available in 833 arteries. High-spatial-resolution CE MRA comprised a measured voxel size of 0.81 mm x 0.81 mm x 1 mm (0.66 mm3). Steno-occlusive vascular disease of the 833 arteries was assessed independently by 2 radiologists according to the NASCET criteria. RESULTS: CE MRA had a sensitivity of 100% (73/73), a specificity of 99.3% (760/765), a positive predictive value of 93.6% (73/78), and a negative predictive value of 100% (760/760) by using a 70% to 99% threshold of arterial diameter stenosis. For detection of occlusion, sensitivity, specificity, PPV, and NPV value of CE MRA were 100%, respectively. CONCLUSIONS: Noninvasive high-spatial-resolution CE MRA is suited to replace diagnostic DSA for the detection of steno-occlusive disease of the supra-aortic arteries.

Adult↗

Parallel imaging in MR angiography.

The recently developed techniques of parallel imaging with phased array coils are rapidly becoming accepted for magnetic resonance angiography (MRA) applications. This article reviews the various current parallel imaging techniques and their application to MRA. The increased scan efficiency provided by parallel imaging allows increased temporal or spatial resolution, and reduction of artifacts in contrast-enhanced MRA (CE-MRA). Increased temporal resolution in CE-MRA can be used to reduce the need for bolus timing and to provide hemodynamic information helpful for diagnosis. In addition, increased spatial resolution (or volume coverage) can be acquired in a breathhold (eg, in renal CE-MRA), or in otherwise limited clinically acceptable scan durations. The increased scan efficiency provided by parallel imaging has been successfully applied to CE-MRA as well as other MRA techniques such as inflow and phase contrast imaging. The large signal-to-noise ratio available in many MRA techniques lends these acquisitions to increased scan efficiency through parallel imaging.

Contrast Media↗

Sensitivity encoding for fast MR imaging of the brain in patients with stroke.

PURPOSE: To evaluate sensitivity encoding (SENSE) technique in a clinical setting for magnetic resonance (MR) imaging in patients who are suspected of having infarction. MATERIALS AND METHODS: This intraindividual comparative study included 62 patients suspected of having cerebral ischemia. Patients underwent T2-weighted fluid-attenuated inversion-recovery (FLAIR) (n = 62), T2-weighted turbo spin-echo (TSE) (n = 48), and single-shot echo-planar diffusion-weighted imaging (n = 27) with standard sequential and SENSE MR acquisitions with a 1.5-T magnet and phased-array coil. With SENSE, acquisition time was reduced from 1 minute 12 seconds to 35 seconds for FLAIR and from 1 minute 18 seconds to 39 seconds for T2-weighted TSE imaging. For diffusion-weighted imaging, echo train length was shortened (78 vs 71 msec) to reduce susceptibility effects while acquisition time was maintained. Two radiologists scored quality of standard and SENSE images with a five-point scale and assessed presence of artifacts (motion, susceptibility) and lesion conspicuity. To assess statistical significance, Wilcoxon signed rank and chi2 tests were used. RESULTS: Statistical analysis revealed no significant difference in terms of image quality and presence of artifacts between standard and SENSE T2-weighted TSE (image quality, P =.724; presence of artifacts, P =.378) and FLAIR (image quality, P =.127; presence of artifacts, P =.275) images. Image quality at SENSE diffusion-weighted imaging was scored significantly higher compared with that at standard diffusion-weighted imaging (P =.002). Susceptibility artifacts were significantly reduced at SENSE diffusion-weighted imaging when compared with those at standard diffusion-weighted imaging (P <.001). Conspicuity of 84 lesions was rated equivalent with both standard and SENSE protocols. CONCLUSION: SENSE allowed acquisition of T2-weighted TSE and FLAIR images with image quality and lesion conspicuity that did not differ from those of standard acquisition techniques but in only half the acquisition time. Use of SENSE with diffusion-weighted imaging significantly reduces susceptibility artifacts while lesion conspicuity is maintained.

Adolescent↗

Time-of-flight MR angiography: comparison of 3.0-T imaging and 1.5-T imaging--initial experience.

Intracranial three-dimensional time-of-flight (TOF) magnetic resonance (MR) angiography was performed in seven healthy volunteers and eight patients with both 1.5-T and 3.0-T MR systems with standard and high spatial resolutions (true voxel sizes, 0.48 x 0.75 x 2.00 mm and 0.30 x 0.44 x 1.00 mm, respectively). Superior image quality and significantly better depiction of small vessel segments and vascular disease were observed at high-spatial-resolution 3.0-T TOF MR angiography but not at standard 1.5-T or standard 3.0-T TOF MR angiography (P <.01, respectively). Intracranial high-spatial-resolution TOF MR angiography at 3.0-T imaging provides diagnostic improvement in studies of cerebrovascular disease.

Adolescent↗

Randomly segmented central k-space ordering in high-spatial-resolution contrast-enhanced MR angiography of the supraaortic arteries: initial experience.

Contrast material-enhanced three-dimensional (3D) magnetic resonance (MR) angiography of the supraaortic arteries with randomly segmented central k-space ordering (ie, contrast-enhanced timing-robust angiography [CENTRA]) was performed in 16 patients. CENTRA enabled reliable depiction of the aortic arch up to the circle of Willis at high spatial resolution (true voxel size, 0.81 x 0.81 x 1.0 mm(3)). With CENTRA, the divergent demands of high spatial resolution, wide anatomic coverage, and arterial phase imaging have been reconciled. The random order of central k-space acquisition may minimize artifacts in contrast-enhanced 3D MR angiography caused by unstable contrast material opacification at the initiation of sampling.

Adult↗