PubMed Health⌕ Search

Biomedical subjects

Wisam A Shihadeh

Publications and source records attributed to Wisam A Shihadeh.

5 recordsLinked to original sources

Ultrasound biomicroscopy in asymmetric pigment dispersion syndrome and pigmentary glaucoma.

OBJECTIVE: To identify differences in anterior chamber anatomy among patients with asymmetric pigment dispersion syndrome and no other discernible cause for the asymmetry. METHODS: Ultrasound biomicroscopy and A-scan biometry were performed on both eyes of 13 patients with asymmetric pigment dispersion syndrome without a known cause for asymmetric involvement. A radial perpendicular image in the horizontal temporal meridian detailing the scleral spur, angle anatomy, and iris configuration was obtained for each eye by 2 examiners. RESULTS: There were no differences in lens thickness (P = .33), refractive error (P = .84), or axial length (P = .99) between more and less affected eyes. However, the mean +/- SD iris concavity (P<.001), iris-lens contact distance (P = .02), and distance from the scleral spur to the iris insertion (0.42 +/- 0.11 vs 0.29 +/- 0.06 mm) (P = .002) were greater in the more affected eye of each patient. CONCLUSION: A more posterior iris insertion predisposes to the phenotypic expression of pigment dispersion syndrome.

Adult↗

Rescue of failed filtering blebs with ab interno trephination.

We evaluated the effectiveness of ab interno automated trephination as a technique for rescuing failed mature filtering blebs. A retrospective chart review of 40 failed blebs of 38 patients who had a posttrephination follow-up period of at least 3 months was done. With success defined as intraocular pressure (IOP) <21 mm Hg and at least a 20% reduction from baseline on the same or fewer number of pretrephination medications, 30/40 eyes (75%) fit these criteria over the entire course of follow-up. Among all 40 eyes, there was a significant reduction of IOP from pretrephination to 3 months (P<.001). The percentage of patients requiring 2 or more medications declined from 90% pretrephination to 21% at 3 months (P<.0001), and was stable thereafter. Some patients were able to eliminate all medications. Patients who did not meet the criteria of success regained successful IOP control with other modalities of management. Complications were few. We believe that ab interno trephination is an excellent option for rescuing selected failed filtering blebs.

Adult↗

Hyphema occurring during selective laser trabeculoplasty.

The first case of hyphema occurring during selective laser trabeculoplasty in an eye without neovascularization is described. A 77-year-old man with uncontrolled open-angle glaucoma received selective laser trabeculoplasty in both eyes for high intraocular pressure with maximally tolerated medical treatment. Hyphema occurred during selective laser trabeculoplasty in the left eye. This resolved spontaneously without sequelae. Successful intraocular pressure control was achieved. Hyphema and bleeding can happen during selective laser trabeculoplasty. Although this was transient and uneventful in one patient, careful monitoring of intraocular pressure and anterior chamber reaction is advised.

Aged↗

A new surgical technique for anterior segment ectasia: tectonic lamellar sclerokeratoplasty.

A 41-year-old patient with severe anterior segment ectasia and a previous history of failed corneal graft was treated by placing a 14-mm tectonic corneoscleral allograft in the eye to support both the corneal and the scleral thinning. Nylon 10-0 interrupted sutures were used at the sclero-scleral junction. The host conjunctiva, including the limbal area, was carefully sutured to the donor limbal area. Three months postoperatively, the graft was stable with no progression of the ectasia. The suturing of a corneoscleral graft over a severely ectatic cornea may be an acceptable technique for providing tectonic tissue support and stabilizing eyes with severe anterior segment ectasia.

Adult↗

A conjunctival retractor for glaucoma filtering surgery.

A new conjunctival retractor provides the desired exposure of the scleral bed during filtering surgery. It elevates the conjunctiva without causing crush injury and allows excellent exposure of the scleral bed with a smaller incision than is required when non-toothed forceps or Weck cell sponges are used. The surgeon or assistant holding the retractor can move it in various directions to provide a good view of any particular site for which exposure is needed.

Conjunctiva↗