Towards quantification of blood-flow changes during cognitive task activation using perfusion-based fMRI.

Multi-slice perfusion-based functional magnetic resonance imaging (p-fMRI) is demonstrated with a color-word Stroop task as an established cognitive paradigm. Continuous arterial spin labeling (CASL) of the blood in the left common carotid artery was applied for all repetitions of the functional run in a quasi-continuous fashion, i.e., it was interrupted only during image acquisition. For comparison, blood oxygen level dependent (BOLD) contrast was detected using conventional gradient-recalled echo (GE) echo planar imaging (EPI). Positive activations in BOLD imaging appeared in p-fMRI as negative signal changes corresponding to an enhanced transport of inverted water spins into the region of interest, i.e., increased cerebral blood flow (CBF). Regional differences between the localization of activations and the sensitivity of p-fMRI and BOLD-fMRI were observed as, for example, in the inferior frontal sulcus and in the intraparietal sulcus. Quantification of CBF changes during cognitive task activation was performed on a multi-subject basis and yielded CBF increases of the order of 20-30%.

Adult↗

Continuous arterial spin labeling at the human common carotid artery: the influence of transit times.

In evaluating the sensitivity of arterial spin labeling (CASL) and for quantification of perfusion, knowledge of the transit time from the labeling plane to the imaging slice is crucial. The purpose of the current study was to obtain estimates of transit times relevant under the specific experimental conditions of CASL in human subjects using a separate local labeling coil at the neck. Specifically, the post-label delay (PLD), i.e. the time between the end of the labeling period and the image acquisition, was varied either with or without additional application of crusher gradients to suppress intravascular signal contributions. The overall sensitivity change for varying the PLD between 1000 and 1700 ms was low. A tissue transit time from the neck to an axial supraventricular section through Broca's knee was obtained by fitting the PLD dependence to a two-compartment model. Averaging over subjects yielded 1930 +/- 110 ms for the tissue transit time, and 73 +/- 5 ml min(-1) 100 g(-1) for the cerebral blood flow. Small areas that exhibited a very high signal change upon labeling were indicative of regional variation in cerebral blood flow related to vascular anatomy.

Adult↗

Continuous arterial spin labeling using a local magnetic field gradient coil.

Continuous arterial spin labeling (ASL) using a locally induced magnetic field gradient for adiabatic inversion of spins in the common carotid artery of human volunteers is demonstrated. The experimental setup consisted of a helmet resonator for imaging, a circular RF surface coil for labeling, and gradient loops to produce a magnetic field gradient. A spin-echo (SE) echo-planar imaging (EPI) sequence was used for imaging. The approach is independent of the gradients of the MR scanner. This technology may be used if the imaging gradient system does not produce an appropriate magnetic field gradient at the location of the carotid artery-for example, in a head-only scanner-and is a prerequisite for the development of a system that allows continuous labeling during the imaging experiment.