PubMed Health⌕ Search

Biomedical subjects

Wolfgang Gaggl

Publications and source records attributed to Wolfgang Gaggl.

6 recordsLinked to original sources

Differential representation of speech sounds in the human cerebral hemispheres.

Various methods in auditory neuroscience have been used to gain knowledge about the structure and function of the human auditory cortical system. Regardless of method, hemispheric differences are evident in the normal processing of speech sounds. This review article, augmented by the authors' own work, provides evidence that asymmetries exist in both cortical and subcortical structures of the human auditory system. Asymmetries are affected by stimulus type, for example, hemispheric activation patterns have been shown to change from right to left cortex as stimuli change from speech to nonspeech. In addition, the presence of noise has differential effects on the contribution of the two hemispheres. Modifications of typical asymmetric cortical patterns occur when pathology is present, as in hearing loss or tinnitus. We show that in response to speech sounds, individuals with unilateral hearing loss lose the normal asymmetric pattern due to both a decrease in contralateral hemispheric activity and an increase in the ipsilateral hemisphere. These studies demonstrate the utility of modern neuroimaging techniques in functional investigations of the human auditory system. Neuroimaging techniques may provide additional insight as to how the cortical auditory pathways change with experience, including sound deprivation (e.g., hearing loss) and sound experience (e.g., training). Such investigations may explain why some populations appear to be more vulnerable to changes in hemispheric symmetry such as children with learning problems and the elderly.

Acoustic Stimulation↗

Molecular characterization of two novel splice variants of G alphai2 in the rat vestibular periphery.

GTP binding proteins play an important role in mediating signals transduced across the cell membrane by membrane-bound receptors. We previously described a partial sequence, termed Galphai2vest, obtained from rat vestibular tissue that was nearly identical to rat Galphai2. Using an experimental strategy to further characterize Galphai2vest (GenBank accession number AF189020) and identify other possible Galphai2-related transcripts expressed in the rat vestibular periphery, we employed a RecA-based gene enrichment protocol in place of conventional library screening techniques. We identified two novel Galphai2 splice variants, Galphai2(a) (GenBank accession number AY899210) and Galphai2(b) (GenBank accession number AY899211), that have most of exons 8 and 9 deleted, and exons 5 through 9 deleted, respectively. In situ hybridization studies were completed to determine the differential expression of Galphai2 between the vestibular primary afferent neurons and the vestibular end organs. Computer modeling and predicted 3D conformation of the wild type Galphai2 and the two splice variants were completed to evaluate the changes associated with the Gbetagamma and GTP binding sites. These two novel alternatively spliced isoforms of Galphai2 putatively encode truncated proteins that could serve unique roles in the physiology of the vestibular neuroepithelium. Galphai2vest was found to be a processed pseudogene.

Alternative Splicing↗

Auditory sensitivity in children using the auditory steady-state response.

OBJECTIVE: To determine the effectiveness of auditory steady-state response (ASSR) as a measure of hearing sensitivity in young children suspect for significant hearing loss. DESIGN: Within-subject comparisons of click auditory brainstem response (ABR) thresholds and ASSR thresholds. SUBJECTS: The study population comprised 42 children suspect for hearing loss and subsequently referred for hearing assessment using electrophysiologic techniques. MAIN OUTCOME MEASURES: Electrophysiologic threshold responses for click ABR and ASSR stimuli (0.5, 1, 2, and 4 kHz) for right and left ears. RESULTS: Based on ABR and ASSR thresholds, 50% of the subjects demonstrated significant hearing loss in the severe to profound range. In some subjects, ASSRs were present at higher stimulus levels when click ABRs were absent. Significant correlations (P<.05) were found between high-frequency ASSR and click ABR thresholds for this study sample. For some subjects, ASSR findings suggested differences between ears that were not observable from the no-response click ABR results. CONCLUSIONS: Auditory steady-state response testing may provide additional information for children who demonstrate hearing levels in the severe to profound range. This information may be helpful when selecting the ear for cochlear implantation for a young hearing-impaired child. Multiple objective methods, such as ABR and ASSR testing, may be needed to determine accurate hearing sensitivity for young children being considered for sensory devices, and in particular, cochlear implants.

Audiometry, Pure-Tone↗

Electrophysiologic effects of placing cochlear implant electrodes in a perimodiolar position in young children.

OBJECTIVE: The purpose of this study was to intraoperatively record the electrically evoked auditory brainstem response (EABR) before and after placement of the electrode positioning system (EPS) (CII Bionic Ear with HiFocus I cochlear implant electrode array) as well as before and after stylet removal (Nucleus Contour cochlear implant electrode array). It was hypothesized that physiologic changes would occur after perimodiolar positioning of the electrode array and these changes would be evident from the EABR recordings. STUDY DESIGN: Consecutive young (11-36 month old) pediatric cochlear implant recipients (n = 17) had intraoperative EABRs recorded from three intracochlear electrodes that represented apical, medial, and basal locations. Wave V amplitudes and thresholds were studied relative to electrode location and pre- versus postperimodiolar positioning. These evoked potential measures were analyzed for statistical significance. SETTING: Tertiary referral children's hospital/medical college. RESULTS: Wave V thresholds of the EABR were lower, and amplitudes were larger after perimodiolar positioning, although the changes were dependent on electrode location and implant design. Statistically significant decreases in EABR wave V threshold and increases in suprathreshold wave V amplitude were found for the basal electrode for the CII Bionic Ear HiFocus I and for the apical electrode for the Nucleus Contour. CONCLUSIONS: Placement of either the CII Bionic Ear HiFocus I or Nucleus Contour cochlear implant electrode array in the perimodiolar position in young children resulted in less electrical current necessary to stimulate the auditory system. Changes in electrophysiologic thresholds and amplitudes, measured with EABR, indicate that the electrode array is placed closer to the modiolus with both electrode designs.

Child, Preschool↗

Recognition of speech presented at soft to loud levels by adult cochlear implant recipients of three cochlear implant systems.

OBJECTIVE: The purpose of this study was to conduct a large-scale investigation with adult recipients of the Clarion, Med-El, and Nucleus cochlear implant systems to (1) determine average scores and ranges of performance for word and sentence stimuli presented at three intensity levels (70, 60, and 50 dB SPL); (2) provide information on the variability of scores for each subject by obtaining test-retest measures for all test conditions; and (3) further evaluate the potential use of lower speech presentation levels (i.e., 60 and/or 50 dB SPL) in cochlear implant candidacy assessment. DESIGN: Seventy-eight adult cochlear implant recipients, 26 with each of the three cochlear implant systems, participated in the study. To ensure that the data collected reflect the range of performance of adult recipients using recent technology for the three implant systems (Clarion HiFocus I or II, Med-El Combi 40+, Nucleus 24M or 24R), a composite range and distribution of consonant-nucleus-consonant (CNC) monosyllabic word scores was determined. Subjects using each device were selected to closely represent this range and distribution of CNC performance. During test sessions, subjects were administered the Hearing in Noise Test (HINT) sentence test and the CNC word test at three presentation levels (70, 60, and 50 dB SPL). HINT sentences also were administered at 60 dB SPL with a signal-to-noise ratio (SNR) of +8 dB. Warble tones were used to determine sound-field threshold levels from 250 to 4000 Hz. Test-retest measures were obtained for each of the speech recognition tests as well as for warble-tone sound-field thresholds. RESULTS: Cochlear implant recipients using the Clarion, Med-El, or Nucleus devices performed on average equally as well at 60 compared with 70 dB SPL when listening for words and sentences. Additionally, subjects had substantial open-set speech perception performance at the softer level of 50 dB SPL for the same stimuli; however, subjects' ability to understand speech was poorer when listening in noise to signals of greater intensity (60 dB SPL + 8 SNR) than when listening to signals presented at a soft presentation level (50 dB SPL) in quiet. A significant correlation was found between sound-field thresholds and speech recognition scores for presentation levels below 70 dB SPL. The results demonstrated a high test-retest reliability with cochlear implant users for these presentation levels and stimuli. Average sound-field thresholds were between 24 and 29 dB HL for frequencies of 250 to 4000 Hz, and results across sessions were essentially the same. CONCLUSIONS: Speech perception measures used with cochlear implant candidates and recipients should reflect the listening challenges that individuals encounter in natural communication situations. These data provide the basis for recommending new candidacy criteria based on speech recognition tests presented at 60 and/or 50 dB SPL, intensity levels that reflect real-life listening, rather than 70 dB SPL.

Adult↗

Electrically evoked auditory brain stem responses for lateral and medial placement of the Clarion HiFocus electrode.

OBJECTIVE: The purpose of this study was to compare the electrically evoked auditory brain stem response (EABR) for lateral and medial placement of the Clarion HiFocus cochlear implant electrode array via the electrode positioning system (EPS). DESIGN: Twenty-five adult and pediatric cochlear implant recipients participated in the study. Intraoperatively recorded EABRs were evoked by stimuli via three intracochlear electrodes representing apical, medial, and basal locations, and responses were elicited before and after positioner insertion. Evoked potential measures of wave V amplitude and threshold were examined for statistical significance using ANOVA for repeated measures and Chi-Square methods. RESULTS: For a given supra-threshold stimulus level, the increase in EABR wave V amplitude was significantly larger after EPS placement compared to before EPS placement for electrodes 1 (apical) and 13 (basal). Likewise, when the stimulus was decreased to obtain a minimal amplitude, the wave V threshold was significantly lower after EPS placement for electrodes 7 (medial) and 13. The number of measurements that showed decreased wave V threshold after EPS insertion was significantly dependent on intracochlear electrode location. CONCLUSIONS: Placement of the Clarion Electrode Positioning System following HiFocus electrode insertion resulted in a reduction in the electrical current required to activate the auditory system. The effect of the EPS was greatest for the basal location, demonstrated by lower wave V thresholds and a larger percentage increase in wave V amplitude. The EABR reflected electrophysiologic changes relative to lateral-to-medial changes in intracochlear electrode position due to the EPS.

Adult↗