HIV-1 genotyping: comparison of two commercially available assays.

HIV-1 resistance testing has become an increasingly important feature in antiretroviral treatment and is commonly accomplished by genotyping. Currently, two different systems are being marketed and, despite being far from easy to use, have achieved a high degree of sophistication. Modifications of the standard-kit protocols may be advantageous in certain situations. Although resistance reports are issued by these systems through interpretation software based on decision rules, it nevertheless requires considerable knowledge and skills by the user to make useful clinical data out of detected resistance patterns. This review describes both systems in detail and discusses their advantages and disadvantages. A final decision on which system to use must be based on an individual's requirements. The future of this field may lie with the use of microarray systems.

Anti-HIV Agents↗

Identification of a novel coronavirus in patients with severe acute respiratory syndrome.

BACKGROUND: The severe acute respiratory syndrome (SARS) has recently been identified as a new clinical entity. SARS is thought to be caused by an unknown infectious agent. METHODS: Clinical specimens from patients with SARS were searched for unknown viruses with the use of cell cultures and molecular techniques. RESULTS: A novel coronavirus was identified in patients with SARS. The virus was isolated in cell culture, and a sequence 300 nucleotides in length was obtained by a polymerase-chain-reaction (PCR)-based random-amplification procedure. Genetic characterization indicated that the virus is only distantly related to known coronaviruses (identical in 50 to 60 percent of the nucleotide sequence). On the basis of the obtained sequence, conventional and real-time PCR assays for specific and sensitive detection of the novel virus were established. Virus was detected in a variety of clinical specimens from patients with SARS but not in controls. High concentrations of viral RNA of up to 100 million molecules per milliliter were found in sputum. Viral RNA was also detected at extremely low concentrations in plasma during the acute phase and in feces during the late convalescent phase. Infected patients showed seroconversion on the Vero cells in which the virus was isolated. CONCLUSIONS: The novel coronavirus might have a role in causing SARS.

Adult↗

Development and clinical application of a fully controlled quantitative PCR assay for cell-free cytomegalovirus in human plasma.

BACKGROUND: Cytomegalovirus (HCMV) disease continues to be a major problem in certain patient groups, including bone marrow transplant (BMT) recipients. The quantification of HCMV genome is clinically useful for the diagnosis of HCMV disease, for the virological surveillance of high-risk patients and for monitoring antiviral therapy. OBJECTIVES: To develop a novel, robust, and fully controlled PCR (qPCR) for the quantification of HCMV DNA in plasma samples and to demonstrate its clinical usefulness in the BMT setting. STUDY DESIGN: The newly developed HCMV qPCR employs cell culture-derived murine CMV as an internal control for both extraction and amplification. Following amplification using common primers, detection of both internal control and patient HCMV amplicons is by specific probes and a chemiluminescence microtitre plate system. Its performance was evaluated using the routine non-quantitative nested HCMV PCR on whole blood (NQPCR) and correlated with clinical events such as disease and antiviral therapy. RESULTS: A high level of concordance (85.1%) was found between the novel assay and the NQPCR, with the qPCR being slightly more sensitive. The samples giving discordant results generally had levels of HCMV DNA close to the limit of detectability or had been stored for prolonged periods. CONCLUSIONS: The use of plasma as an analyte by the newly developed assay avoids the detection of cell-associated virus. On the other hand, testing a comparatively large volume of plasma ensures that sensitivity is not compromised by not detecting cell-associated HCMV. In a small preliminary evaluation in BMT recipients, changes in HCMV 'viral load' correlated with initiation and discontinuation of antiviral therapy and were biologically plausible.

Base Sequence↗

Role of China in the quest to define and control severe acute respiratory syndrome.

China holds the key to solving many questions crucial to global control of severe acute respiratory syndrome (SARS). The disease appears to have originated in Guangdong Province, and the causative agent, SARS coronavirus, is likely to have originated from an animal host, perhaps sold in public markets. Epidemiologic findings, integral to defining an animal-human linkage, may be confirmed by laboratory studies; once animal host (s) are confirmed, interventions may be needed to prevent further animal-to-human transmission. Community seroprevalence studies may help determine the basis for the decline in disease incidence in Guangdong Province after February 2002. China will also be able to contribute key data about how the causative agent is transmitted and how it is evolving, as well as identifying pivotal factors influencing disease outcome.

Animals↗

Comparison of nine resistance interpretation systems for HIV-1 genotyping.

HIV-1 genotyping has become a widely accepted tool for monitoring antiretroviral therapy. However, the benefit of genotyping is limited by the need to interpret the mutation pattern in order to obtain a prediction regarding susceptibility to each antiretroviral drug. Several different interpretation systems are currently available, commercially or free of charge; some are in combination with the genotyping test system used. In this study, we compared the results obtained on patient samples, using nine different resistance interpretation systems for HIV-1 genotype, and identified mutation patterns responsible for discordances between these systems. HIV-1 genotypes from 26 patients were obtained using the ViroSeq HIV-1 Genotyping System (Applied Biosystems). Nine resistance interpretation systems were used: the 'virtual phenotype' systems VirtualPhenotype (Virco) and Geno2Pheno (http://cartan.gmd.de/geno2pheno.html), the rule-based resistance algorithms Antiretroviral Drug Resistance Report (Applied Biosystems), Stanford HIV-SEQ program (http://hivdb.stanford.edu/) and the ViroScorer system (ABL; including ANRS AC11, Detroit Medical Center, Grupo de Aconselhamento Virológico, CHL, and Rega). Discordance was defined as the same sequence being interpreted as resistant and sensitive to a substance by different systems, with intermediate scores being regarded as neutral. Results for lopinavir were not available from some interpretation systems. None of the 26 patient samples had concordant results for all drugs. The highest degree of concordance was found for the resistance scoring of lamivudine (25/26), followed by nelfinavir (23/26), indinavir, ritonavir, saquinavir (all 22/26), zidovudine, nevirapine (all 21/26), lopinavir, efavirenz (all 18/26), amprenavir, delavirdine (all 17/26), stavudine, abacavir (all 13/26), zalcitabine (7/26) and didanosine (5/26). In most cases, it was only one interpretation system that gave an interpretation different from the others. If this interpretation system was omitted, the overall discordance rate decreased by a statistically significant degree. There exists, therefore, an urgent need for standardization of interpretation algorithms for HIV-1 genotyping.

Anti-HIV Agents↗

Evaluation of the Cobas AmpliPrep/Cobas Amplicor HIV-1 Monitor Ultrasensitive Test: comparison with the Cobas Amplicor HIV-1 Monitor test (manual specimen preparation).

In this preliminary study, we evaluated the performance of the Cobas AmpliPrep/Cobas Amplicor HIV-1 Monitor Ultrasensitive Test (CAP; Roche Molecular Systems, Branchburg, NJ) for automated specimen preparation and quantitative detection of human immunodeficiency virus type 1 (HIV-1) RNA and compared it to the Cobas Amplicor HIV-1 Monitor Ultrasensitive Test (MCA; Roche), which includes a manual sample preparation protocol. A dilution panel of a patient sample was prepared. Additionally, 584 EDTA plasma samples were collected from HIV-1 infected patients. Reproducibility was estimated with six assay runs using the dilution panel. The inter-assay coefficient of variation ranged from 39.4 to 48.4% (CAP assay) and from 34.3 to 45.6% (MCA assay), whereas the intra-assay coefficient of variation ranged from 6.2 to 58.0% (CAP assay) and from 4.4 to 57.3% (MCA assay). Comparison of CAP assay results with the HIV-1 copy number of the dilution panel determined by the MCA assay resulted in a good agreement, although the CAP results were found to be slightly lower. A significant correlation between both test systems was found when clinical samples were analyzed. The mean viral load of 152 samples, which were within the linear range of both tests, was 3.70 log(10) HIV-1 copies/ml by the CAP assay compared to 3.73 by the MCA assay. In conclusion, we could demonstrate that the new Cobas AmpliPrep/Cobas Amplicor HIV Monitor Ultrasensitive Test is reproducible and sensitive. In comparison to the assay with manual extraction, no significant difference in HIV-1 RNA copy numbers was observed.

HIV Infections↗

Viral genome quantification as a tool for improving patient management: the example of HIV, HBV, HCV and CMV.

In recent years, new therapeutic options have led to enormous improvements in the management of certain chronic viral infections. Nevertheless, it has also become clear that such treatments require careful consideration and follow up. At the same time, a number of new technologies have been developed to measure quantitatively the concentration of viral genome in the patient's body fluids. Initially, these tests yielded important insights into the pathogenesis of viral infections and, in the case of human immunodeficiency virus (HIV), in fact revolutionized our understanding of its natural history. In addition, however, such 'viral load' tests have become vital tools in patient management; formerly pure research tools, they are now widely used in routine virological diagnosis, and a number of commercial assays have become available. In clinical virology, viral load testing serves four purposes: for diagnosis; to assess the patient's prognosis; as therapeutic markers to monitor the effect of antiviral treatment; and to estimate the patient's infectivity, i.e. the risk of transmission. In this review paper, we summarize the current role of viral genome quantification in the clinical management of patients infected with HIV, hepatitis B virus, hepatitis C virus and those at risk of developing human cytomegalovirus-related diseases.

Cytomegalovirus↗