Ion trajectory simulation for electrode configurations with arbitrary geometries.

A multi-particle ion trajectory simulation program ITSIM 6.0 is described, which is capable of ion trajectory simulations for electrode configurations with arbitrary geometries. The electrode structures are input from a 3D drawing program AutoCAD and the electric field is calculated using a 3D field solver COMSOL. The program CreatePot acts as interface between the field solver and ITSIM 6.0. It converts the calculated electric field into a field array file readable by ITSIM 6.0 and ion trajectories are calculated by solving Newton's equation using Runge-Kutta integration methods. The accuracy of the field calculation is discussed for the ideal quadrupole ion trap in terms of applied mesh density. Electric fields of several different types of devices with 3D geometry are simulated, including ion transport through an ion optical system as a function of pressure. Ion spatial distributions, including the storage of positively charged ions only and simultaneous storage of positively/negatively charged ions in commercial linear ion traps with various geometries, are investigated using different trapping modes. Inelastic collisions and collision induced dissociation modeled using RRKM theory are studied, with emphasis on the fragmentation of n-butylbenzene inside an ideal quadrupole ion trap. The mass spectrum of 1,3-dichlorobenzene is simulated for the rectilinear ion trap device and good agreement is observed between the simulated and the experimental mass spectra. Collisional cooling using helium at different pressures is found to affect mass resolution in the rectilinear ion trap.

Journal Article↗

Novel linear ion trap mass analyzer composed of four planar electrodes.

A novel linear ion trap mass analyzer was developed using just four elongated planar electrodes, mounted in parallel, and employing an RF potential for ion trapping in the radial and axial directions. Mass analysis was achieved using the mass-selective instability scan with ion ejection in the radial direction. The performance of this new device was characterized in comparison with the 6-electrode rectilinear ion trap (RIT) from which it is derived. The 4-electrode trap gives optimum performance in an asymmetric geometry, just like the original optimized 6-electrode RIT. The strong RF fringing fields at the ends of the RF rods account for axial ion trapping without use of extra electrodes or an axial DC voltage. Field calculations and simulations have been carried out to study the trapping potential inside RITs with various configurations. Demonstrated capabilities include analysis of externally injected ions with mass resolution in excess of 1000 and a mass/charge range of 650 Th as well as tandem mass spectrometry capabilities. The geometric simplicity and performance characteristics of the 4-electrode RIT make it particularly attractive in the development of next generation miniaturized mass spectrometers.

Journal Article↗

Rectilinear ion trap: concepts, calculations, and analytical performance of a new mass analyzer.

A mass analyzer based on a rectilinear geometry ion trap (RIT) has been built, and its performance has been characterized. Design concepts for this type of ion trap are delineated with emphasis on the effects of electrode geometry on the calculated electric field. The Mathieu stability region was mapped experimentally. The instrument can be operated using mass-selective instability scans in both the boundary and resonance ejection versions. Comparisons of performance between different versions of the device having different dimensions allowed selection of an optimized geometry with an appropriate distribution of higher-order electric fields. Comparisons made under the same conditions between the performance of a conventional cylindrical ion trap and a RIT of 4 times greater volume show an improvement of 40 times in the signal-to-noise ratio resulting from the higher ion trapping capacity of the RIT. The demonstrated capabilities of the RIT include tandem mass spectrometry, a mass resolution in excess of 1000, and a mass/charge range of 650 Th, all in a simple structure that is only 3.5 cm(3) in internal volume.

Equipment Design↗

A model for energy transfer in inelastic molecular collisions applicable at steady state or non-steady state and for an arbitrary distribution of collision energies.

A new model for energy exchange between translational and internal degrees of freedom in atom-molecule collisions has been developed. It is suitable for both steady state conditions (e.g., a large number of collisions with thermal kinetic energies) and non-steady state conditions with an arbitrary distribution of collision energies (e.g., single high-energy collisions). In particular, it does not require that the collision energies be characterized by a quasi-thermal distribution, but nevertheless it is capable of producing a Boltzmann distribution of internal energies with the correct internal temperature under quasi-thermal conditions. The energy exchange is described by a transfer probability density that depends on the initial relative kinetic energy, the internal energy of the molecule, and the amount of energy transferred. The probability density for collisions that lead to excitation is assumed to decrease exponentially with the amount of transferred energy. The probability density for de-excitation is obtained from microscopic reversibility. The model has been implemented in the ion trap simulation program ITSIM and coupled with an Rice-Rampsberger-Kassel-Marcus (RRKM) algorithm to describe the unimolecular dissociation of populations of ions. Monte Carlo simulations of collisional energy transfer are presented. The model is validated for non-steady state conditions and for steady state conditions, and the effect of the kinetic energy dependence of the collision cross-section on internal temperature is discussed. Applications of the model to the problem of chemical mass shifts in RF ion trap mass spectrometry are shown.

Journal Article↗

Chemical mass shifts in resonance ejection experiments in the quadrupole ion trap.

Chemical mass shifts were measured in a Paul ion trap operated in the mass-selective instability scan with resonance ejection using a custom-built instrument. These shifts, which can be as much as 2%, decrease with increasing endcap electrode separation owing to changes in the higher order contributions to the electric field. They also decrease with decreasing helium buffer gas pressure. Both of these effects are analogous to those found with boundary ejection. This suggests that the previously proposed chemical mass shift mechanism based on compound-dependent collisional modification of the ejection delay produced by field faults near the endcap electrode apertures holds true also for resonance ejection. The influence of the resonance frequency on chemical mass shifts was also investigated and it is shown that at certain working points (values of the Mathieu parameter q(z) and a(z)) non-linear resonances greatly reduce the ejection delay for all ions, regardless of their chemical structures, and thus reduce the magnitude of the chemical mass shift. Energetic collisions leading to dissociation can take place at an earlier stage during the ejection process in the mass analysis scan when using resonance ejection compared with boundary ejection. This leads to even larger chemical mass shifts of fragile ions in resonance ejection. Increasing the resonance voltage amplitude can enhance this effect. The chemical mass shifts of fragile ions increase with increase in the resonance voltage amplitude, whereas negligible changes occur for structurally stable ions.

Journal Article↗

Correlations of chemical mass shifts of para-substituted acetophenones and benzophenones with Brown's sigma constants.

Relationships between chemical mass shifts and physiochemical properties of ions are sought by examining substituted acetophenones, benzophenones, and pyridines in a modified ion trap mass spectrometer. Systematic changes in chemical mass shift occur with changes in substituent in the acetophenones and the benzophenones. Brown's sigma+ constant, which is a measure of electronic effects of substituents in reactions that involve positive charge development, is shown to correlate linearly with chemical mass shifts in para-substituted acetophenones and benzophenones. Brown's sigma+ constant also correlates with the ease of dissociation of the ions via a correlation with ionization energy. It is suggested that ease of dissociation is the underlying factor in determining chemical mass shifts. The experimental results also suggest that dissociative collisions between ions and buffer gas make a much greater contribution to chemical mass shifts than do elastic collisions.

Journal Article↗