Clinical implementation of target tracking by breathing synchronized delivery.

Target-tracking techniques can be categorized based on the mechanism of the feedback loop. In real time tracking, breathing-delivery phase correlation is provided to the treatment delivery hardware. Clinical implementation of target tracking in real time requires major hardware modifications. In breathing synchronized delivery (BSD), the patient is guided to breathe in accordance with target motion derived from four-dimensional computed tomography (4D-CT). Violations of mechanical limitations of hardware are to be avoided at the treatment planning stage. Hardware modifications are not required. In this article, using sliding window IMRT delivery as an example, we have described step-by-step the implementation of target tracking by the BSD technique: (1) A breathing guide is developed from patient's normal breathing pattern. The patient tries to reproduce this guiding cycle by following the display in the goggles; (2) 4D-CT scans are acquired at all the phases of the breathing cycle; (3) The average tumor trajectory is obtained by deformable image registration of 4D-CT datasets and is smoothed by Fourier filtering; (4) Conventional IMRT planning is performed using the images at reference phase (full exhalation phase) and a leaf sequence based on optimized fluence map is generated; (5) Assuming the patient breathes with a reproducible breathing pattern and the machine maintains a constant dose rate, the treatment process is correlated with the breathing phase; (6) The instantaneous average tumor displacement is overlaid on the dMLC position at corresponding phase; and (7) DMLC leaf speed and acceleration are evaluated to ensure treatment delivery. A custom-built mobile phantom driven by a computer-controlled stepper motor was used in the dosimetry verification. A stepper motor was programmed such that the phantom moved according to the linear component of tumor motion used in BSD treatment planning. A conventional plan was delivered on the phantom with and without motion. The BSD plan was also delivered on the phantom that moved with the prescheduled pattern and synchronized with the delivery of each beam. Film dosimetry showed underdose and overdose in the superior and inferior regions of the target, respectively, if the tumor motion is not compensated during the delivery. BSD delivery resulted in a dose distribution very similar to the planned treatments.

Algorithms↗

Precautions in the use of intensity-modulated radiation therapy.

Intensity-modulated radiation therapy (IMRT) represents a significant technological advancement in the ability to deliver highly conformal radiation therapy. Thanks to increased availability, general clinical implementation has become progressively more common. However, there are several precautions worthy of comment regarding the clinical applications of IMRT. In theory, the increased irradiated volume and leakage radiation that occasionally accompanies IMRT could contribute to unanticipated complications and safety concerns. The protracted delivery time of IMRT with the associated increased linac monitor units can result in photoactivation of elements within the linac collimator, thereby inadvertently increasing radiation exposure to patients and staff when high-energy photons are used. The increased volumes of normal tissue exposed to lower doses of radiation through IMRT theoretically could promote carcinogenesis and complications due to the bystander effect, low-dose hyper-radiosensitivity, and diminished repair of double strand DNA breaks at very low doses. Tumor control may be adversely affected by the lower radiation dose-rates of delivery sometimes associated with IMRT as well the occasionally seen low dose "cold shoulder" on the dose-volume histograms. Unusual clinical reactions can appear as a result of the complex, unfamiliar dose-distributions occasionally generated by IMRT treatment planning. Here we discuss some of the precautions worthy of consideration when using IMRT and how these might be addressed in routine practice.

Animals↗

Potential for radiation therapy technology innovations to permit dose escalation for non-small-cell lung cancer.

BACKGROUND: Innovations in radiation therapy (RT) technology could have the potential to allow for radiation dose escalation by evaluating tumor motion, minimizing and compensating for motion, and evaluating delivery technologies such as 3-dimensional (3D) conformal radiation therapy (CRT) and intensity-modulated RT (IMRT) using tomotherapy. MATERIALS AND METHODS: Ninety different RT plans were generated using 3 different treatment techniques for 10 patients. These were evaluated using dosimetric tools such as dose-volume histogram (DVH) analysis, tumor equivalent uniform dose (EUD), and dosimetric parameters predictive for lung toxicity, such as the volume of lung receiving > 20 Gy of radiation (V20) and the normalized mean total radiation dose to the lung (NTDmean). The 3 techniques studied included free breathing using 3D CRT, 3D CRT with maximum-inspiration breath-hold (MIBH) to minimize tumor motion, and IMRT delivery with MIBH; the combination of 3 separate planning treatment-volume sets resulted in the generation of 90 different treatment plans. To plan these, patients underwent treatment-planning computed tomography in MIBH and free breathing followed by simulation with measurement of tumor motion and generation/evaluation of DVHs, EUDs, V20, and NTDmean. RESULTS: Average tumor motion was 1.54 cm in the cephalocaudad directions, 1.26 cm in the anteroposterior directions, and 0.56 cm in the lateral directions between maximum inspiration and expiration. Maximum-inspiration breath-hold produced superior lung sparing evidenced by lower V20 and NTDmean values, and these parameters predicted lower modeled pneumonitis rates. Tomotherapy-based IMRT provided further lung sparing. CONCLUSION: Treatment in MIBH results in lower V20 and NTDmean values and lower modeled pneumonitis rates. This effect is enhanced by the use of IMRT. The use of MIBH with IMRT may therefore aid in escalating the dose in RT.

Adenocarcinoma↗

Image guidance for precise conformal radiotherapy.

PURPOSE: To review the state of the art in image-guided precision conformal radiotherapy and to describe how helical tomotherapy compares with the image-guided practices being developed for conventional radiotherapy. MATERIALS AND METHODS: Image guidance is beginning to be the fundamental basis for radiotherapy planning, delivery, and verification. Radiotherapy planning requires more precision in the extension and localization of disease. When greater precision is not possible, conformal avoidance methodology may be indicated whereby the margin of disease extension is generous, except where sensitive normal tissues exist. Radiotherapy delivery requires better precision in the definition of treatment volume, on a daily basis if necessary. Helical tomotherapy has been designed to use CT imaging technology to plan, deliver, and verify that the delivery has been carried out as planned. The image-guided processes of helical tomotherapy that enable this goal are described. RESULTS: Examples of the results of helical tomotherapy processes for image-guided intensity-modulated radiotherapy are presented. These processes include megavoltage CT acquisition, automated segmentation of CT images, dose reconstruction using the CT image set, deformable registration of CT images, and reoptimization. CONCLUSIONS: Image-guided precision conformal radiotherapy can be used as a tool to treat the tumor yet spare critical structures. Helical tomotherapy has been designed from the ground up as an integrated image-guided intensity-modulated radiotherapy system and allows new verification processes based on megavoltage CT images to be implemented.