Wolfhard Semmler

Publications and source records attributed to Wolfhard Semmler.

At least 19 recordsLinked to original sources

B1 field-insensitive transformers for RF-safe transmission lines.

OBJECTIVE: Integration of transformers into transmission lines suppresses radiofrequency (RF)-induced heating. New figure-of-eight-shaped transformer coils are compared to conventional loop transformer coils to assess their signal transmission properties and safety profile. MATERIALS AND METHODS: The transmission properties of figure-of-eight-shaped transformers were measured and compared to transformers with loop coils. Experiments to quantify the effect of decoupling from the B1 field of the MR system were conducted. Temperature measurements were performed to demonstrate the effective reduction of RF-induced heating. The transformers were investigated during active tracking experiments. RESULTS: Coupling to the B1 field was reduced by 18 dB over conventional loop-shaped transformer coils. MR images showed a significantly reduced artifact for the figure-of-eight- shaped coils generated by local flip-angle amplification. Comparable transmission properties were seen for both transformer types. Temperature measurements showed a maximal temperature increase of 30 K/3.5 K for an unsegmented/segmented cable. With a segmented transmission line a robotic assistance system could be successfully localized using active tracking. CONCLUSION: The figure-of-eight-shaped transformer design reduces both RF field coupling with the MR system and artifact sizes. Anatomical structure close to the figure-of-eight-shaped transformer may be less obscured as with loop-shaped transformers if these transformers are integrated into e.g. intravascular catheters.

Equipment Design↗

Comparison of noncontact and fiber-based fluorescence-mediated tomography.

We present a comparative experimental phantom study of fiber-based and noncontact fluorescence tomography with respect to quantitation and localization of reconstructed fluorescent inclusions in turbid media such as tissue. Noncontact acquisition is usually considered potentially superior to fiber-based techniques because of the availability of a large number of detector readouts through a CCD. Our results indicate, however, that noncontact acquisition itself might improve the quality of reconstructions significantly, even without increasing the number of detectors and thus keeping the inverse problem moderately complex.

Equipment Design↗

Dual-bolus approach to quantitative measurement of pulmonary perfusion by contrast-enhanced MRI.

PURPOSE: To evaluate a dual-bolus approach to pulmonary perfusion MRI. MATERIALS AND METHODS: The dual-bolus approach uses a separate low-dose measurement for the arterial input function (AIF) to ensure linearity. The measured AIF is constructed according to a subsequent higher dose used for the tissue concentration curves in the lung. In this study a prebolus of 0.01 mmol/kg followed by doses of 0.04 mmol/kg and 0.08 mmol/kg was used. Measurements were performed using time-resolved two-dimensional fast low-angle shot (2D FLASH) MRI (TE/TR = 0.73 msec/1.73 msec; flip angle = 40 degrees ; generalized autocalibrating partially parallel acquisitions (GRAPPA) factor = 3; temporal resolution = 400 msec) in end-inspiratory breath-hold. RESULTS: The combination of prebolus/0.04 mmol/kg resulted in a pulmonary blood flow (PBF) of 211 +/- 77 mL/min/100 mL, and a pulmonary blood volume (PBV) of 20 +/- 3 mL/100 mL. The combination of prebolus/0.08 mmol/kg resulted in approximately 50% lower perfusion values, most likely due to saturation effects in the lung tissue. CONCLUSION: A dual-bolus approach to pulmonary perfusion MRI is feasible and may reduce the problem of lacking linear relationship between the contrast-agent concentration and signal intensity.

Adult↗

Active catheter tracking using parallel MRI and real-time image reconstruction.

In this work active MR catheter tracking with automatic slice alignment was combined with an autocalibrated parallel imaging technique. Using an optimized generalized autocalibrating partially parallel acquisitions (GRAPPA) algorithm with an acceleration factor of 2, we were able to reduce the acquisition time per image by 34%. To accelerate real-time GRAPPA image reconstruction, the coil sensitivities were updated only after slice reorientation. For a 2D trueFISP acquisition (160 x 256 matrix, 80% phase matrix, half Fourier acquisition, TR = 3.7 ms, GRAPPA factor = 2) real-time image reconstruction was achieved with up to six imaging coils. In a single animal experiment the method was used to steer a catheter from the vena cava through the beating heart into the pulmonary vasculature at an image update rate of about five images per second. Under all slice orientations, parallel image reconstruction was accomplished with only minor image artifacts, and the increased temporal resolution provided a sharp delineation of intracardial structures, such as the papillary muscle.

Algorithms↗

Dynamic coil selection for real-time imaging in interventional MRI.

MR-guided intravascular interventions require image update rates of up to 10 images per second, which can be achieved using parallel imaging. However, parallel imaging requires many coil elements, which increases reconstruction times and thus compromises real-time image reconstruction. In this study a dynamic coil selection (DCS) algorithm is presented that selects a subset of receive coils to reduce image reconstruction times. The center-of-sensitivity coordinates and the relative signal intensities are determined for each coil in a prescan. During the intervention m coils are selected for reconstruction using a coil ranking based on the distance to the current slice or catheter position. In a phantom experiment for m = 6, an optimal signal-to-background ratio (SBR) was achieved and foldover artifacts were avoided. In three animal experiments involving catheter manipulation in the aorta and the right heart chamber, the anatomy was successfully visualized at frame rates of about 5 Hz using active catheter tracking.

Algorithms↗

From 2D PET to 3D PET: issues of data representation and image reconstruction.

Positron emission tomography (PET), intrinsically a 3D imaging technique, was for a long time exclusively operated in 2D mode, using septa to shield the detectors from photons emitted obliquely to the detector planes. However, the use of septa results in a considerable loss of sensitivity. From the late 1980s, significant efforts have been made to develop a methodology for the acquisition and reconstruction of 3D PET data. This paper focuses on the differences between data acquisition in 2D and 3D mode, especially in terms of data set sizes and representation. Although the real time data acquisition aspect in 3D has been mostly solved in modern PET scanner systems, there still remain questions on how to represent and how to make best use of the information contained in the acquired data sets. Data representation methods, such as list-mode and matrix-based methods, possibly with additional compression, will be discussed. Moving from 2D to 3D PET has major implications on the way these data are reconstructed to images. Two fundamentally different approaches exist, the analytical one and the iterative one. Both, at different expenses, can be extended to directly handle 3D data sets. Either way the computational burden increases heavily compared to 2D reconstruction. One possibility to benefit from the increased sensitivity in 3D PET while sticking to high-performance 2D reconstruction algorithms is to rebin 3D into 2D data sets. The value of data rebinning will be explored. An ever increasing computing power and the concept of distributed or parallel computing have made direct 3D reconstruction feasible. Following a short review of reconstruction methods and their extensions to 3D, we focus on numerical aspects that improve reconstruction performance, which is especially important in solving large equation systems in 3D iterative reconstruction. Finally exemplary results are shown to review the properties of the discussed algorithms. This paper concludes with an overview on future trends in data representation and reconstruction.

Humans↗

Quantification of aortic elasticity: development and experimental validation of a method using computed tomography.

Aortic distensibility depending on aortic cross-sectional area changes is an important parameter for the grading of vascular diseases. This study measured aortic area changes by multidetector computed tomography. An image reconstruction algorithm was developed to assess aorta diameter and area as a function of the cardiac cycle with sufficient time resolution along the entire length of the aorta by four-detector row computed tomography. The algorithm was tested on porcine aortic specimens and compared with an optical reference method. The error of the relative vessel area change comparing the two methods was found to be about 3%. Initial tests on patient datasets indicate that clinical application is feasible. The proposed method has the advantage that it can easily be integrated into a modified routine CT angiography study and allows the measurement of aortic cross-sectional area changes.

Anatomy, Cross-Sectional↗

Influence of different breathing maneuvers on internal and external organ motion: use of fiducial markers in dynamic MRI.

PURPOSE: To investigate, with dynamic magnetic resonance imaging (dMRI) and a fiducial marker, the influence of different breathing maneuvers on internal organ and external chest wall motion. METHODS AND MATERIALS: Lung and chest wall motion of 16 healthy subjects (13 male, 3 female) were examined with real-time trueFISP (true fast imaging with steady-state precession) dMRI and a small inductively coupled marker coil on either the abdomen or thorax. Three different breathing maneuvers were performed (predominantly "abdominal breathing," "thoracic breathing," and unspecific "normal breathing"). The craniocaudal (CC), anteroposterior (AP), and mediolateral (ML) lung distances were correlated (linear regression coefficient) with marker coil position during forced and quiet breathing. RESULTS: Differences of the CC distance between maximum forced inspiration and expiration were significant between abdominal and thoracic breathing (p < 0.05). The correlation between CC distance and coil position was best for forced abdominal breathing and a marker coil in the abdominal position (r = 0.89 +/- 0.04); for AP and ML distance, forced thoracic breathing and a coil in the thoracic position was best (r = 0.84 +/- 0.03 and 0.82 +/- 0.03, respectively). In quiet breathing, a lower correlation was found. CONCLUSION: A fiducial marker coil external to the thorax in combination with dMRI is a new technique to yield quantitative information on the correlation of internal organ and external chest wall motion. Correlations are highly dependent on the breathing maneuver.

Abdomen↗

Improved correlation of histological data with DCE MRI parameter maps by 3D reconstruction, reslicing and parameterization of the histological images.

Due to poor correlation of slice thickness and orientation, verification of radiological methods with histology is difficult. Thus, a procedure for three-dimensional reconstruction, reslicing and parameterization of histological data was developed, enabling a proper correlation with radiological data. Two different subcutaneous tumors were examined by MR microangiography and DCE-MRI, the latter being post-processed using a pharmacokinetic two-compartment model. Subsequently, tumors were serially sectioned and vessels stained with immunofluorescence markers. A ray-tracing algorithm performed three-dimensional visualization of the histological data, allowing virtually reslicing to thicker sections analogous to MRI slice geometry. Thick slices were processed as parameter maps color coding the marker density in the depth of the slice. Histological 3D reconstructions displayed the diffuse angioarchitecture of malignant tumors. Resliced histological images enabled specification of high enhancing areas seen on MR microangiography as large single vessels or vessel assemblies. In orthogonally reconstructed histological slices, single vessels were delineated. ROI analysis showed significant correlation between histological parameter maps of vessel density and MR parameter maps (r=0.83, P=0.05). The 3D approach to histology improves correlation of histological and radiological data due to proper matching of slice geometry. This method can be used with any histological stain, thus enabling a multivariable correlation of non-invasive data and histology.

Algorithms↗

[Measurements of respiratory motion using fast magnetic resonance imaging and inductively-coupled marker coils].

The respiratory motion of the thoracic wall provides indirect information about the breathing displacement of the inner organs. To analyze the correlation between thoracic wall and lung motion for applications in radiation therapy, the breathing displacement of the lung is visualized with a fast gradient echo pulse sequence (trueFISP) at a rate of 2-3 images/sec. For quantification of the motion, a small inductively-coupled marker coil is attached to the chest wall and detected with a fast projection technique. Since the marker coil generates a flip angle amplification (factor 15) in its interior, very small nominal flip angles of 2 degrees can be used during the projection measurements which do not affect the image quality of the trueFISP images. Volunteer studies with the marker coil showed a good agreement with simultaneously acquired breathing belt data and position information extracted from the MR images. Whereas the breathing belt provided reliable data only within a certain dynamic range, the marker coil could detect also extreme breathing excursions with a precision better than 2 millimeters.

Equipment Design↗

[Principles of optical and fluorescence mediated tomography in turbid media].

Three-dimensional, tomographic imaging of biological tissues by means of visible light is becoming increasingly important. Current progress in the mathematical-physical modelling of photon propagation in scattering media allows spatially-resolved reconstructions of optical parameters with common computing hardware. Especially in the field of molecular imaging, optical tomography promises a transfer of knowledge from successful in vitro assays (as evaluated by fluorescence microscopy) to in vivo imaging of living animals. In the latter case, spatial resolution is not as critical as the ability to quantify the concentration of fluorescence-labelled probes, a task not solvable by the use of common planar imaging techniques. In this article, the theoretical foundations of optical tomography are introduced along with some examples of applications.

Image Processing, Computer-Assisted↗

[Status and perspectives of non invasive cell tracking].

The interaction of different cells is an important regulator in the development of many diseases, including cancer. Some cells are recruited directly from the local tissue environment, others reach the pathological focus via the circulation. Using non-invasive cell tracking methods, the distribution and migration of labeled cells can be studied in experimental animal models, and the role of these cells on the pathogenesis of disease can thus be elucidated. Scintigraphy and SPECT, and especially MRI and optical imaging, are frequently used for this purpose. Studies are mostly performed with macrophages and granulocytes (inflammatory cells), which accumulate in nephritis, encephalitis, and tumors. At present, the understanding of progenitor cell migration and differentiation is gaining increasing interest in neurological disorders (for example Parkinson's disease) and in cardiac diseases (for example myocardial infarction). Non-invasive cell tracking is already established in basic research; in the future, a clinical application of cell tracking is foreseeable in the framework of cell therapy.

Granulocytes↗

Physical and biological characterization of superparamagnetic iron oxide- and ultrasmall superparamagnetic iron oxide-labeled cells: a comparison.

RATIONALE: Superparamagnetic iron-oxide particles are used frequently for cellular magnetic resonance imaging and in vivo cell tracking. The purpose of this study was to compare the labeling characteristics and efficiency as well as toxicity of superparamagnetic iron oxide (SPIO) and ultrasmall superparamagnetic iron oxide (USPIO) for 3 cell lines. METHODS: Using human fibroblasts, immortalized rat progenitor cells and HEP-G2-hepatoma cells, dose- and time-dependence of SPIO and USPIO uptake were evaluated. The amount of intracellular (U)SPIO was monitored over 2 weeks after incubation by T2-magnetic resonance relaxometry, ICP-mass-spectrometry, and histology. Transmission-electronmicroscopy was used to specify the intracellular localization of the endocytosed iron particles. Cell death-rate and proliferation-index were assessed as indicators of cell-toxicity. RESULT: For all cell lines, SPIO showed better uptake than USPIO, which was highest in HEP-G2 cells (110 +/- 2 pg Fe/cell). Cellular iron concentrations in progenitor cells and fibroblasts were 13 +/- 1pg Fe/cell and 7.2 +/- 0.3pg Fe/cell, respectively. For all cell lines T2-relaxation times in cell pellets were below detection threshold (<3 milliseconds) after 5 hours of incubation with SPIO (3.0 micromol Fe/mL growth medium) and continued to be near the detection for the next 6 days. For both particle types and all cell lines cellular iron oxide contents decreased after recultivation and surprisingly were found lower than in unlabeled control cells after 15 days. Viability and proliferation of (U)SPIO-labeled and unlabeled cells were not significantly different. CONCLUSIONS: The hematopoetic progenitor, mesenchymal fibroblast and epithelial HEP-G2 cell lines accumulated SPIO more efficiently than USPIO indicating SPIO to be better suited for cell labeling. However, the results indicate that there may be an induction of forced cellular iron elimination after incubation with (U)SPIO.

Animals↗

Potential applications of flat-panel volumetric CT in morphologic and functional small animal imaging.

Noninvasive radiologic imaging has recently gained considerable interest in basic and preclinical research for monitoring disease progression and therapeutic efficacy. In this report, we introduce flat-panel volumetric computed tomography (fpVCT) as a powerful new tool for noninvasive imaging of different organ systems in preclinical research. The three-dimensional visualization that is achieved by isotropic high-resolution datasets is illustrated for the skeleton, chest, abdominal organs, and brain of mice. The high image quality of chest scans enables the visualization of small lung nodules in an orthotopic lung cancer model and the reliable imaging of therapy side effects such as lung fibrosis. Using contrast-enhanced scans, fpVCT displayed the vascular trees of the brain, liver, and kidney down to the subsegmental level. Functional application of fpVCT in dynamic contrast-enhanced scans of the rat brain delivered physiologically reliable data of perfusion and tissue blood volume. Beyond scanning of small animal models as demonstrated here, fpVCT provides the ability to image animals up to the size of primates.

Animals↗

Volumetric computed tomography (VCT): a new technology for noninvasive, high-resolution monitoring of tumor angiogenesis.

Volumetric computed tomography (VCT) is a technology in which area detectors are used for imaging large volumes of a subject with isotropic imaging resolution. We are experimenting with a prototype VCT scanner that uses flat-panel X-ray detectors and is designed for high-resolution three-dimensional (3D) imaging. Using this technique, we have demonstrated microangiography of xeno-transplanted skin squamous cell carcinomas in nude mice. VCT shows the vessel architecture of tumors and animals with greater detail and plasticity than has previously been achieved, and is superior to contrast-enhanced magnetic resonance (MR) angiography. VCT and MR images correlate well for larger tumor vessels, which are tracked from their origin on 3D reconstructions of VCT images. When compared with histology, small tumor vessels with a diameter as small as 50 microm were clearly visualized. Furthermore, imaging small vessel networks inside the tumor tissue improved discrimination of vital and necrotic regions. Thus, VCT substantially improves imaging of vascularization in tumors and offers a promising tool for preclinical studies of tumor angiogenesis and antiangiogenic therapies.

Animals↗

Simple models improve the discrimination of prostate cancers from the peripheral gland by T1-weighted dynamic MRI.

Evaluation of the accuracy of descriptive and physiological parameters calculated from signal intensity-time curves using T1-weighted dynamic contrast enhanced MRI (DCE MRI) to differentiate prostate cancers from the peripheral gland. Twenty-seven patients with prostate cancers were examined with DCE MRI prior radical prostatectomy. Regions of interest were defined in tumors and non-affected areas in the peripheral zone. Dynamic data were parameterized in amplitude and exchange rate constant (kep) using a two-compartment model. Additionally, relative slope during 26, 39, 52 and 65 s, areas under the curve (AUC) and time to start of signal intensity increase (tlag) were determined. Vessel density (VD) of excised prostates was quantified in tumor areas using a CD34 stain. The parameter slope52 showed 20% higher values (P<0.001) in tumors than in the peripheral gland and compared with the other parameters the largest area under the ROC curve (0.81). The minimum total error rate was attained at a cut-point of 0.021, yielding a sample value of sensitivity and specificity of 70% and 88%, respectively, and a bias-corrected sum of sensitivity and specificity of 1.54. In addition, amplitude (P<0.001), kep (P=0.03) and AUC (P<0.001) were significantly higher in tumors. tlag did not discriminate carcinomas from glandular tissue. VD was higher in tumors than in the non-affected peripheral prostate (P=0.05). However, none of the dynamic parameters in carcinomas showed a significant correlation with VD or Gleason score. Although pharmacokinetic modeling in DCE MRI showed potential to discriminate prostate cancers from peripheral prostate tissue, descriptive parameters of the early signal enhancement after contrast media injection reached higher sensitivity and specificity.

Aged↗

MR-guided intravascular procedures: real-time parameter control and automated slice positioning with active tracking coils.

PURPOSE: To implement and optimize a real-time pulse sequence and user interface to perform intravascular interventions using active catheter tracking. MATERIALS AND METHODS: In magnetic resonance (MR)-guided interventions, small radio-frequency coils can be used to rapidly determine the device position (active tracking). In this work, active catheter tracking was combined with a dedicated real-time pulse sequence and user interface. The pulse sequence offered the imaging contrasts fast low angle shot (FLASH), true Fast imaging with steady state precession (TrueFISP), and projection MR digital subtraction angiography (MR-DSA), which could be selected by the radiologist from within the scanner room at any time during the intervention. Automatic slice positioning was added to the real-time pulse sequence so that the location of the tracking coils defined the image slice position and orientation. The technique was assessed in phantoms and animal experiments. RESULTS: At a reaction time of 24 msec and a frame rate of three images per second, the movement of an active intravascular catheter could be monitored in the aorta and the renal arteries of a pig. With interactive contrast and orientation changes, the renal vasculature could be assessed by a fully MR-guided catheterization in less than 10 minutes. CONCLUSION: With carefully designed active catheters, a dedicated user interface, and an optimized pulse sequence intravascular interventions can successfully be performed by a single operator from within the MR scanner room.

Animals↗

MR coil design for simultaneous tip tracking and curvature delineation of a catheter.

In active catheter tracking, small RF coils are attached to the catheter for localization. For interactive catheter steering at vessel branchings, it is necessary to visualize not only a single point near the catheter tip but also the entire shape and orientation of the catheter's distal end. Therefore, a 35-mm-long twisted-pair RF coil was added to a 5 French intravascular catheter with a single tip-tracking coil. With the use of small nonmagnetic electronic components at the catheter tip, and a special switching circuitry outside the catheter, the coil assembly could be operated in two different modes. During MRI, the tip-tracking coil was detuned so that the MR signal was received by the visualization coil only. During tracking, detuning was switched off and the MR signal was predominantly received by the more sensitive tracking coil. The catheter was used in combination with a MR pulse sequence with automatic slice positioning so that the current imaging slice was always placed at the position of the catheter tip. Phantom and animal experiments showed that the catheter tip is better visualized with the combined approach than with a tracking coil alone.

Animals↗