PubMed Health⌕ Search

Biomedical subjects

Won Oak Kim

Publications and source records attributed to Won Oak Kim.

2 recordsLinked to original sources

Learning by computer simulation does not lead to better test performance than textbook study in the diagnosis and treatment of dysrhythmias.

STUDY OBJECTIVE: To compare computer-based learning with traditional learning methods in studying advanced cardiac life support (ACLS). DESIGN: Prospective, randomized study. SETTING: University hospital. MEASUREMENTS: Senior medical students were randomized to perform computer simulation and textbook study. Each group studied ACLS for 150 minutes. Tests were performed 1 week before, immediately after, and 1 week after the study period. Testing consisted of 20 questions. All questions were formulated in such a way that there was a single best answer. Each student also completed a questionnaire designed to assess computer skills, as well as satisfaction with and benefit from the study materials. MAIN RESULTS: Test scores improved after both textbook study and computer simulation study in both groups, although the improvement in scores was significantly higher for the textbook group only immediately after the study. There was no significant difference between groups in their computer skill and satisfaction with the study materials. The textbook group reported greater benefit from study materials than did the computer simulation group. CONCLUSIONS: Studying ACLS with a hard-copy textbook may be more effective than computer simulation for acquiring simple information during a brief period. However, the difference in effectiveness is likely transient.

Adult↗

Monitoring of PETCO2 during high frequency jet ventilation for laryngomicrosurgery.

In general, PETCO2 is well correlated with PaCO2 during spontaneous and conventional mechanical ventilation in normal lungs. However, it is known that during high frequency jet ventilation, PETCO2 may underestimate PaCO2 because of inadequate washout of the anatomical dead space by a small tidal volume and the relatively slow response time of infrared CO2 analyzers. The validity of PETCO2 as a reflection of PaCO2 was assessed during HFJV in 40 patients undergoing laryngeal microsurgery. HFJV was applied through an injector inserted into the trachea 6 cm below the vocal cord. PETCO2 was obtained from a sampling line placed 2 cm below the injector. Both PETCO2 and PaCO2 were measured simultaneously after decreasing the frequency from 100 beats per minute to 15 beats per minute 10 and 20 minutes after the commencement of HFJV. There was a strong correlation (r = 0.955, P < 0.001) and a good correspondence between the mean PETCO2 and PaCO2 values with an average difference of 1.93 +/- 1.21 mmHg and a limit of agreement from -0.49 to 4.35 mmHg. It is suggested that the PETCO2 obtained following a decrease in the jet frequency during HFJV could closely reflect PaCO2.

Adult↗