Dose escalation to combat hypoxia in prostate cancer: a radiobiological study on clinical data.

Earlier studies have demonstrated that hypoxic regions exist in human prostate cancer and the degree of hypoxia correlates with the treatment outcome of radiotherapy. Using the concept of the clinical oxygen enhancement ratio (COER), the linear-quadratic (LQ) model was extended to account for the effect of tumour hypoxia. The clinical data collected at the Fox Chase Cancer Center for prostate cancer were analysed based on the LQ model as well as the tumour control probability (TCP) model. The LQ and TCP parameters (alpha = 0.15 Gy (-1), alpha/beta = 3.1 Gy and the number of clonogens K = 10(6) approximately 10(7) cells) determined in earlier studies were used to derive the COER for prostate cancer: COER = 1.4 with a standard confidence interval (CI) of (1.2, 1.8). The result is consistent with the in vitro OER measurements of human tumour cell lines under chronic hypoxia conditions. This implies that a higher dose is needed to overcome tumour hypoxia. For prostate tumours, the prescription dose required to overcome tumour hypoxia is 165 Gy (CI: 153 approximately 186 Gy) for permanent 125I implants and 88 Gy (CI: 74 approximately 118 Gy) in 2 Gy fractions for external-beam radiotherapy. The impact of LQ parameters on the calculations of COER and dose escalation was discussed. This study provides a preliminary estimate of the dose escalation needed to overcome tumour hypoxia based on clinical data. More clinical data with better statistics and longer follow-up time are required to further tune the radiobiological modelling of hypoxia for prostate cancer.

Brachytherapy↗

Inverse planning for intensity-modulated arc therapy using direct aperture optimization.

Intensity-modulated arc therapy (IMAT) is a radiation therapy delivery technique that combines gantry rotation with dynamic multi-leaf collimation (MLC). With IMAT, the benefits of rotational IMRT can be realized using a conventional linear accelerator and a conventional MLC. Thus far, the advantages of IMAT have gone largely unrealized due to the lack of robust automated planning tools capable of producing efficient IMAT treatment plans. This work describes an inverse treatment planning algorithm, called 'direct aperture optimization' (DAO) that can be used to generate inverse treatment plans for IMAT. In contrast to traditional inverse planning techniques where the relative weights of a series of pencil beams are optimized, DAO optimizes the leaf positions and weights of the apertures in the plan. This technique allows any delivery constraints to be enforced during the optimization, eliminating the need for a leaf-sequencing step. It is this feature that enables DAO to easily create inverse plans for IMAT. To illustrate the feasibility of DAO applied to IMAT, several cases are presented, including a cylindrical phantom, a head and neck patient and a prostate patient.

Algorithms↗

Direct aperture optimization: a turnkey solution for step-and-shoot IMRT.

IMRT treatment plans for step-and-shoot delivery have traditionally been produced through the optimization of intensity distributions (or maps) for each beam angle. The optimization step is followed by the application of a leaf-sequencing algorithm that translates each intensity map into a set of deliverable aperture shapes. In this article, we introduce an automated planning system in which we bypass the traditional intensity optimization, and instead directly optimize the shapes and the weights of the apertures. We call this approach "direct aperture optimization." This technique allows the user to specify the maximum number of apertures per beam direction, and hence provides significant control over the complexity of the treatment delivery. This is possible because the machine dependent delivery constraints imposed by the MLC are enforced within the aperture optimization algorithm rather than in a separate leaf-sequencing step. The leaf settings and the aperture intensities are optimized simultaneously using a simulated annealing algorithm. We have tested direct aperture optimization on a variety of patient cases using the EGS4/BEAM Monte Carlo package for our dose calculation engine. The results demonstrate that direct aperture optimization can produce highly conformal step-and-shoot treatment plans using only three to five apertures per beam direction. As compared with traditional optimization strategies, our studies demonstrate that direct aperture optimization can result in a significant reduction in both the number of beam segments and the number of monitor units. Direct aperture optimization therefore produces highly efficient treatment deliveries that maintain the full dosimetric benefits of IMRT.

Algorithms↗

Optimized intensity-modulated arc therapy for prostate cancer treatment.

We recently implemented intensity-modulated arc therapy (IMAT) at our institution. In this study, we evaluate the dosimetric merits of the application of this technique to the treatment of prostate cancer. Each IMAT treatment plan incorporated bilateral overlapping arcs. The dose from each beam segment was computed using the three-dimensional dose model of a clinical treatment planning system (Render Plan 3.5, Precision Therapy). The weights assigned to the individual arc segments were optimized using a gradient search method. For 12 patients, comparisons were made between the IMAT treatment plans and corresponding plans using fixed cone-beam intensity-modulated radiotherapy (IMRT) from a commercial inverse planning system (CORVUS, NOMOS Corp.). We found that the optimized IMAT treatments produced similar dose distributions to the IMRT deliveries. Compared with the IMRT treatments, the IMAT treatments produced slightly less target dose homogeneity with consistently greater sparing of the rectum in regions of lower dose. The trade-off between target dose conformity and rectum sparing can be adjusted in both optimization procedures. Because the total beam-on time for IMAT delivery is 1 to 2 minutes with approximately 5-6 minutes of patient setup time, the delivery efficiency of the IMAT treatment was significantly better than the multiple-beam IMRT treatment.

Humans↗

Dose effects of guide wires for catheter-based intravascular brachytherapy.

PURPOSE: Guide wires with high torquability and steerability are commonly used to navigate through a tortuous and/or branching arterial tree in a catheter-based intravascular brachytherapy procedure. The dosimetric effects due to the presence of metallic guide wires have not been addressed. This work investigates these dose effects for the three most commonly used beta and gamma sources (90Sr, 32P, and 192Ir). METHODS AND MATERIALS: The EGS4 Monte Carlo codes were used to calculate the dose distributions for the 90Sr(NOVOSTE), 32P (Guidant), and 192Ir (BEST Ind.) with and without a guide wire in place. Energy spectra for particles exiting the sources were calculated from the full phase-space data obtained from the Monte Carlo simulations of the source constructions. Guide wires of various thicknesses and compositions were studied. RESULTS: The dose perturbations due to the presence of guide wires were found to be far more significant for the 90Sr/90Y and 32P beta sources than those for the 192Ir gamma source. Because of the attenuation by the guide wires, a dose reduction of up to 60% behind a guide wire was observed for the beta sources, whereas the dose perturbation was found to be negligible for the gamma source. For a beta source, the dose perturbations depend on the thickness and the material of the guide wire. When the region behind a guide wire is part of an intravascular brachytherapy target, the presence of the guide wire results in a significant underdosing for beta sources. The underdosed region can extend a few mm behind the guide wire and up to 1 mm in other directions. CONCLUSION: Significant dose perturbations by the presence of a metallic guide wire have been found in catheter-based intravascular brachytherapy using beta sources. The dose effects should be considered in the dose prescription and/or in analyzing the treatment outcome for beta sources. Such precautions are not necessary if using a gamma source.

Beta Particles↗

Rat aortic smooth muscle cell density affects activation of MAP kinase and Akt by menadione and PDGF homodimer BB.

Mitogen-activated protein kinases (MAPK) and protein kinase B (PKB or Akt) are major signal transduction molecules regulating cell proliferation, differentiation, and apoptosis. We examined how cultured rat aortic vascular smooth muscle cells (VSMC) at different cell densities respond to selected stimuli and how this is reflected in the two distinct (MAPK and Akt) and yet cross-talking signaling pathways. VSMC were cultured to 100% confluence, reaching contact inhibition, and to 60-70% confluence, as sparse, proliferating cells. They were treated with menadione (an intracellular generator of O(-2)) and/or platelet-derived growth factor homodimer BB (PDGF). In sparse cells, menadione or PDGF alone activated ERK, and together the effect was synergistic, whereas in confluent cells menadione's and PDGF's activations of ERK were, at most, additive. Activation of the upstream ERK kinase (MEK-1) paralleled ERK activation except in sparse cells in which the synergistic effects of menadione and PDGF on ERK could not be fully accounted for by MEK-1 activation. Another member of the MAPK family, p38, did not show significant changes. Akt activation by PDGF alone was present under both cell culture conditions; Akt activation is blocked by menadione. Co-incubation with the reducing agent dithiothreitol or calcium chelators (EDTA/EGTA) inhibited partially or completely menadione's effects on MEK/ERK and Akt pathways, as well as menadione's effects on PDGF-induced ERK and Akt activations. These data suggest that in VSMC, the state of cell confluence determines how distinct pathways of MAPK activation cross talk. In addition while PDGF may function as a survival factor by inducing Akt activation, menadione could promote apoptosis by inhibiting PDGF-induced Akt activation independent of cell density. The effects of menadione, but not those of PDGF, are more dependent on the cellular redox status and extracellular calcium.

Animals↗

Inactivation of the MEK/ERK pathway in the myocardium during cardiopulmonary bypass.

OBJECTIVES: A general pro-inflammatory response after cardiopulmonary bypass (CPB) may involve changes in signal transduction and in part be responsible for arrhythmias and myocardial dysfunction after cardiac surgery. The MEK/ERK (mitogen-activated protein kinase kinase/extracellular regulated kinase) pathway is common to many stimuli and may play a pivotal role in morbidity associated with CPB. We investigated the changes in MEK/ERK pathway and related enzymes after CPB in pigs. METHODS: We examined ventricular and atrial tissue from pigs before 90 minutes of normothermic CPB and after 90 minutes of post-CPB perfusion. The activities and protein levels of kinases MEK1/2, ERK1/2, a cellular tyrosine kinase (c-Src), protein kinase B (Akt), and the protein levels of mitogen-activated protein kinase phosphatase (MKP-1) were studied by immunoblotting ventricular and atrial myocardium lysates and labeling sections with antibodies that recognize the activated forms of the kinases and the phosphatase. Control pigs were subjected to sternotomy and heparinization but not CPB. RESULTS: We found a consistent inactivation of MEK/ERK pathway in both ventricular and atrial myocardium with an increase in MKP-1, a negative regulator of ERK1/2. The activities and protein levels of c-Src and Akt were not significantly modified before or after CPB, suggesting a certain degree of specificity for the MEK/ERK pathway. Such changes were not observed in controls. The decrease of ERK1/2 and MEK1/2 phosphorylation 90 minutes after termination of CPB (as well as the increase of nuclear MKP-1 protein levels) was also apparent by confocal microscopy. CONCLUSIONS: These results collectively reveal a prevalence of inhibitory mechanisms in the MEK/ERK signal transduction machinery in myocardium subjected to CPB.

Animals↗

Analysing collimator structure effects in head-scatter calculations for IMRT class fields using scatter raytracing.

The frequent blocking of the irradiated volume in intensity modulated radiation therapy (IMRT) makes the head-scatter fraction of the incident photon fluence more significant than that in conventional therapy with open fields. On the other hand. certain collimator configurations block scatter photons directed to a given observation point while allowing primary photons to be transmitted. The 'anomalous blocking' makes the primary field a poor indicator of the scatter fluence. Since large MU-to-cGy ratios in IMRT can magnify head-scatter uncertainties, it becomes necessary to accurately model both the effective scatter source and the collimator structure that limits the scatter reaching the irradiated volume. First we obtain a dual-source model, using a Taylor series expansion to derive the effective scatter source distribution from the data measured for the Elekta SL20 linac equipped with a multi-leaf collimator (MLC). Then, using a raytracing algorithm, we calculate the transmission of scatter rays from the effective scatter source plane to points in the patient plane. The method can account for the anomalous blocking of scatter by the MLC leaves and the backup diaphragms. For a variety of collimator settings tested, the calculations agree with measurements to an accuracy of 0.002psi10 x 10, where psi10 x 10 is the total (primary + scatter) photon fluence of an open 10 x 10 cm2 field for the same MU delivered. Although the significance of collimator structure in IMRT depends strongly on fields shapes employed for the delivery, potential cumulative errors on the order of a few per cent can be avoided in fluence calculations if the proposed method is used.

Algorithms↗

Monte Carlo dose verification for intensity-modulated arc therapy.

Intensity-modulated arc therapy (IMAT), a technique which combines beam rotation and dynamic multileaf collimation, has been implemented in our clinic. Dosimetric errors can be created by the inability of the planning system to accurately account for the effects of tissue inhomogeneities and physical characteristics of the multileaf collimator (MLC). The objective of this study is to explore the use of Monte Carlo (MC) simulation for IMAT dose verification. The BEAM/DOSXYZ Monte Carlo system was implemented to perform dose verification for the IMAT treatment. The implementation includes the simulation of the linac head/MLC (Elekta SL20), the conversion of patient CT images and beam arrangement for 3D dose calculation, the calculation of gantry rotation and leaf motion by a series of static beams and the development of software to automate the entire MC process. The MC calculations were verified by measurements for conventional beam settings. The agreement was within 2%. The IMAT dose distributions generated by a commercial forward planning system (RenderPlan. Elekta) were compared with those calculated by the MC package. For the cases studied, discrepancies of over 10% were found between the MC and the RenderPlan dose calculations. These discrepancies were due in part to the inaccurate dose calculation of the RenderPlan system. The computation time for the IMAT MC calculation was in the range of 20-80 min on 15 Pentium-Ill computers. The MC method was also useful in verifying the beam apertures used in the IMAT treatments.

Dose-Response Relationship, Radiation↗

Monte Carlo dose calculations of beta-emitting sources for intravascular brachytherapy: a comparison between EGS4, EGSnrc, and MCNP.

The dose parameters for the beta-particle emitting 90Sr/90Y source for intravascular brachytherapy (IVBT) have been calculated by different investigators. At a distant distance from the source, noticeable differences are seen in these parameters calculated using different Monte Carlo codes. The purpose of this work is to quantify as well as to understand these differences. We have compared a series of calculations using an EGS4, an EGSnrc, and the MCNP Monte Carlo codes. Data calculated and compared include the depth dose curve for a broad parallel beam of electrons, and radial dose distributions for point electron sources (monoenergetic or polyenergetic) and for a real 90Sr/90Y source. For the 90Sr/90Y source, the doses at the reference position (2 mm radial distance) calculated by the three code agree within 2%. However, the differences between the dose calculated by the three codes can be over 20% in the radial distance range interested in IVBT. The difference increases with radial distance from source, and reaches 30% at the tail of dose curve. These differences may be partially attributed to the different multiple scattering theories and Monte Carlo models for electron transport adopted in these three codes. Doses calculated by the EGSnrc code are more accurate than those by the EGS4. The two calculations agree within 5% for radial distance <6 mm.

Beta Particles↗

Conformal photon-beam therapy with transverse magnetic fields: a Monte Carlo study.

This work studies the idea of using strong transverse magnetic (B) fields with high-energy photon beams to enhance dose distributions for conformal radiotherapy. EGS4 Monte Carlo code is modified to incorporate charged particle transport in B fields and is used to calculate effects of B fields on dose distributions for a variety of high-energy photon beams. Two types of hypothetical B fields, curl-free linear fields and dipole fields, are used to demonstrate the idea. The major results from the calculation for the linear B fields are: (1) strong transverse B fields (> 1 T) with high longitudinal gradients (G) (> 0.5 T/cm) can produce dramatic dose enhancement as well as dose reduction in localized regions for high-energy photon beams; (2) the magnitude of the enhancement (reduction) and the geometric extension and the location of this enhancement (reduction) depend on the strength and gradient of the B field, and photon-beam energy; (3) for a given B field, the dose enhancement generally increases with photon-beam energy; (4) for a 5 T B field with infinite longitudinal gradient (solenoidal field), up to 200% of dose enhancement and 40% of dose reduction were obtained along the central axis of a 15 MV photon beam; and (5) a 60% of dose enhancement was observed over a 2 cm depth region for the 15 MV beam when B = 5 T and G = 2.5 T/cm. These results are also observed, qualitatively, in the calculation with the dipole B fields. Calculations for a variety of B fields and beam configurations show that, by employing a well-designed B field in photon-beam radiotherapy, it is possible to achieve a significant dose enhancement within the target, while obtaining a substantial dose reduction over critical structures.

Biophysical Phenomena↗

Reducing loss in lateral charged-particle equilibrium due to air cavities present in x-ray irradiated media by using longitudinal magnetic fields.

The underdosing of lesions distal to air cavities, such as those found in upper respiratory passages, occurs due to the loss in lateral charged-particle equilibrium (CPE). The degree of underdosing worsens for smaller field sizes, resulting in more frequent recurrence of the cancer treated. Higher photon energies further aggravate the outcome by producing longer second build-up regions beyond the cavity. Besides underdosing, the larger lateral spread of secondary electron fluence in the air cavity produces diffuse dose distributions at the tissue-air interface for shaped or intensity modulated fields. These disequilibrium effects create undesirable deviations from the intended treatment. The clinical concern is further intensified by the failure of traditional treatment planning systems to even account for such defects. In this work, the use of longitudinal magnetic fields on the order of 0.5 T is proposed for alleviating lateral electronic disequilibrium due to the presence of air cavities in the irradiated volume. The magnetic field enforces lateral CPE by restricting the lateral range of electrons in the air cavity. The problem is studied in a simple water-air-water slab geometry using EGS4 Monte Carlo simulations for 6 MV photons. Electronic disequilibrium is evaluated for beams of various sizes, shapes and intensity distributions constructed by linear superposition of the dose distributions for 0.5 x 0.5 cm2 beamlets. Comparison is also made with 60Co irradiation. The results indicate that the lateral confinement of secondary electrons in the air cavity by sub-MRI strength longitudinal fields is effective in reducing deterioration of dose distributions near tissue-air interfaces. This can potentially reduce recurrence rates of cancers such as the larynx carcinoma.

Cobalt Radioisotopes↗

Dynamic wedge versus physical wedge: a Monte Carlo study.

The purpose of this study is to analyze the characteristics of dynamic wedges (DW) and to compare DW to physical wedges (PW) in terms of their differences in affecting beam spectra, energy fluence, angular distribution, contaminated electrons, and dose distributions. The EGS4/BEAM Monte Carlo codes were used to simulate the exact geometry of a 6 MV beam and to calculate 3-D dose distributions in phantom. The DW was simulated in accordance with the segmented treatment tables (STT). The percentage depth dose curves and beam profiles for PW, DW, and open fields were measured and used to verify the Monte Carlo simulations. The Monte Carlo results were found to agree within 2% with the measurements performed using film and ionizing chambers in a water phantom. The present EGS4 calculation reveals that the effects of a DW on beam spectral and angular distributions, as well as electron contamination, are much less significant than those for a PW. For the 6 MV photon beam, a 45 degrees PW can result in a 30% increase in mean photon energy due to the effect of beam hardening. It can also introduce a 5% dose reduction in the build-up region due to the reduction of contaminated electrons by the PW. Neither this mean-energy increase nor such dose reduction is found for a DW. Compared to a DW, a PW alters the photon-beam spectrum significantly. The dosimetric differences between a DW and a PW are significant and clearly affect the clinical use of these beams. The data presented may be useful for DW commissioning.

Electrons↗

Dosimetric effects of contrast media for catheter-based intravascular brachytherapy.

The purpose of this work is to calculate the dose perturbations due to the presence of iodine contrast media in catheter-based intravascular brachytherapy (IVBT). The EGSnrc Monte Carlo system was used to perform the calculation for the two most commonly used beta and gamma sources (90Sr and 192Ir as well as for a variety of monoenergetic photon and electron sources. Various contrast media with cylindrical-shell shapes were considered. The dose perturbations due to the presence of iodine contrast media were found to be significant for IVBT. In the region outside of the contrast media (usually the treatment target region for IVBT), the dose is generally increased for the gamma source, while it is decreased for the beta source. In the presence of a 1.0-mm-thick common clinical contrast medium, the dose enhancement can be as high as 30% for the 192Ir source, while the dose can be reduced by up to 25% for the 90Sr source. The dose enhancement region for the gamma source extends approximately 1.0 mm away from the contrast medium, while the dose reduction for the beta source affects the entire target region. The dose perturbation depends on (1) the volume (thickness) of the contrast medium, (2) the iodine concentration in contrast media, and (3) the type and energy of radioactive source. The dose effects due to the contrast medium as well as the differences between beta and gamma sources, revealed in this study, should be recognized and may be considered in the dose prescription for intravascular brachytherapy. These effects should also be taken into account in analyzing the treatment outcome for those IVBT clinical trials involving a contrast medium.

Algorithms↗

Practical aspects of in situ 16O (gamma,n) 15O activation using a conventional medical accelerator for the purpose of perfusion imaging.

We report investigations into the feasibility of generating radioactive oxygen (15O, a positron emitter, with half-life 2.05 min) using a tuned Elekta SL25 accelerator, for the end purpose of imaging tumor perfusion. 15O is produced by the "gamma, neutron," (gamma,n) reaction between high-energy photons and normal oxygen (16O) in the body. As most in vivo 16O is bound in water molecules the 15O radio-marker is produced in proportion to water content in tissue. Imaging the washout of the 15O distribution using sensitive positron-emission-tomography (PET) technology can yield spatial information about blood perfusion in the tissue. The aim of this article was to determine the amount of 15O activity that could be produced by the tuned medical accelerator. A further aim was to model the activation process using Monte Carlo and to investigate ways to optimize the amount of 15O that could be generated. Increased activation was achieved by (i) tuning the beam to give higher-energy electrons incident on the target of the accelerator, (ii) increasing dose rate by removing the conventional filtration in the beam and reducing the source to object distance, and (iii) reducing low-energy photons by means of a carbon block absorber. The activity per-unit-dose produced by the tuned beam was measured by irradiating spheres of water to known doses and placing the spheres in a calibrated coincidence-counting apparatus. Peak energy of the tuned bremsstrahlung beam was estimated at 29 MeV, and generated activity up to 0.24/microCi/cc/3Gy in water. The measured amount of 15O agreed to within 10% of the prediction from the Monte-Carlo-computed spectrum, indicating reasonable ability to model the activation process. The optimal thickness of the carbon absorber was found to be about 25 cm. The insertion of a carbon absorber improved spectral quality for activation purposes but at the cost of reduced dose rate. In conclusion, the viability of generating 15O with an Elekta SL25 has been demonstrated. In conjunction with recent advances in high-sensitivity portable PET imaging devices, real potential exists for imaging in situ activated 15O washout as a surrogate measurement of macroscopic tumor perfusion.

Calibration↗

Monte Carlo characterization of a 32P source for intravascular brachytherapy.

In this work, we have calculated the two-dimensional dose distribution in water for a 32P intravascular brachytherapy source wire using the EGSnrc Monte Carlo code. The beta source (Guidant Vascular Intervention) has a radioactive core with a length of 27 mm and a diameter of 0.24 mm. The dose parameters required by the AAPM TG-60 formalism are discussed and calculated. Dose rate evaluated at the reference point is 0.1311+/-0.0001 Gy min(-1) mCi(-1). For the beta source studied, the dose distribution is uniform along the axial direction z for a given radial position p for - 10 mm< or =z< or =10 mm and p< or =7 mm. In such a dose-uniformity region, the dose field can be characterized by one-dimensional dose distribution, D(p), the dose distribution on the transverse axis. Beyond this region a two-dimensional (2D) description is necessary. However, for the long beta source wire the anisotropy function proposed by the TG-60 formalism becomes indefinable when the radial distance exceeds penetration depth of beta electrons. We have proposed that the anisotropy function be expressed in the cylindrical coordinate system, instead of a polar system, to remedy this deficiency. For practical purposes, the entire 2D dose distribution and the dose parameters calculated in the work are tabulated for ease of use.

Anisotropy↗

Beta versus gamma for catheter-based intravascular brachytherapy: dosimetric perspectives in the presence of metallic stents and calcified plaques.

PURPOSE: Both beta and gamma emitters are currently used in the catheter-based intravascular brachytherapy. The dosimetric effects due to the presence of metallic stents and calcified plaques have not been fully addressed. This work compares these effects for two most commonly used beta and gamma sources ( (90)Sr and (192)Ir). MATERIALS AND METHODS: An EGS4 Monte Carlo package was used to calculate dose in water for a (90)Sr (supplied by NOVOSTE) and an (192)Ir (Supplied by BEST) source, with or without the presence of a calcified plaque or a metallic stent. Plaques of different shape (shell and disk), size and density, and two types of stainless-steel stents (ring or mesh stent) were studied. The ring stent consists of identical rings stacked along the long axis of the sources. The gap between two rings is 0.3 mm. The mesh stents are made of identical square (0.1 x 0.1 or 0.2 x 0.2 mm(2)) holes separated from each other by stainless-steel wire. The cross section of wire for both ring and mesh stents is 0.1 x 0.1 mm(2). A dose perturbation factor (DPF), defined as the ratio of the doses with and without the presence of a plaque or a stent, was introduced to quantify the effects. A carefully chosen set of EGS4 transport parameters for the small geometry in question was used in the calculation. RESULTS: The radial and axial dose distributions calculated in water were found to agree with the published measurements to within 3%. The dose perturbations due to the presence of calcified plaques or metallic stents were found far more significant for the (90)Sr source than those for the (192)Ir source. Up to 30% dose reduction behind a plaque were observed for the (90)Sr source, while the dose reduction for the (192)Ir source was found to be negligible. The dose enhancement inside a plaque was as high as 10% for the beta source or 6% for the gamma source. In the presence of a stent, the DPF was in the range of 1.15-0.75 for the beta source, while it was almost equal to 1.0 for the gamma source. CONCLUSION: The dose perturbation due to the presence of a calcified plaque or a metallic stent is significant for the beta source. The dose reduction in the region beyond a plaque or a stent could be more than 20%. For the gamma source, the dose effect behind a plaque or a stent is practically negligible. These dosimetric differences between the beta and gamma sources in the presence of a calcified plaque or metallic stent should be considered in the dose prescription of intravascular brachytherapy.

Beta Particles↗

An efficient method of measuring the 4 mm helmet output factor for the Gamma knife.

It is essential to have accurate measurements of the 4 mm helmet output factor in the treatment of trigeminal neuralgia patients using the Gamma Knife. Because of the small collimator size and the sharp dose gradient at the beam focus, this measurement is generally tedious and difficult. We have developed an efficient method of measuring the 4 mm helmet output factor using regular radiographic films. The helmet output factor was measured by exposing a single Kodak XV film in the standard Leksell spherical phantom using the 18 mm helmet with 30-40 of its plug collimators replaced by the 4 mm plug collimators. The 4 mm helmet output factor was measured to be 0.876 +/- 0.009. This is in excellent agreement with our EGS4 Monte Carlo simulated value of 0.876 +/- 0.005. This helmet output factor value also agrees with more tedious TLD, diode and radiochromic film measurements that were each obtained using two separate measurements with the 18 mm helmet and the 4 mm helmet respectively. The 4 mm helmet output factor measured by the diode was 0.884 +/- 0.016, and the TLD measurement was 0.890 +/- 0.020. The radiochromic film measured value was 0.870 +/- 0.018. Because a single-exposure measurement was performed instead of a double exposure measurement, most of the systematic errors that appeared in the double-exposure measurements due to experimental setup variations were cancelled out. Consequently, the 4 mm helmet output factor is more precisely determined by the single-exposure approach. Therefore, routine measurement and quality assurance of the 4 mm helmet output factor of the Gamma Knife could be efficiently carried out using the proposed single-exposure technique.

Film Dosimetry↗