PubMed Health⌕ Search

Biomedical subjects

X Favereau

Publications and source records attributed to X Favereau.

At least 19 recordsLinked to original sources

A comparison of systematic stenting and conventional balloon angioplasty during primary percutaneous transluminal coronary angioplasty for acute myocardial infarction. STENTIM-2 Investigators.

OBJECTIVES: In a multicenter, randomized trial, systematic stenting using the Wiktor stent was compared to conventional balloon angioplasty with provisional stenting for the treatment of acute myocardial infarction (AMI). BACKGROUND: Primary angioplasty in AMI is limited by in-hospital recurrent ischemia and a high restenosis rate. METHODS: A total of 211 patients with AMI <12 h from symptom onset, with an occluded native coronary artery, were randomly assigned to systematic stenting (n = 101) or balloon angioplasty (n = 110). The primary end point was the binary six-month restenosis rate determined by core laboratory quantitative angiographic analysis. RESULTS: Angiographic success (Thrombolysis in Myocardial Infarction [TIMI] flow grade 3 and residual diameter stenosis <50%) was achieved in 86% of the patients in the stent group and in 82.7% of those in the balloon angioplasty group (p = 0.5). Compared with the 3% cross-over in the stent group, cross-over to stenting was required in 36.4% of patients in the balloon angioplasty group (p = 0.0001). Six-month binary restenosis (> or = 50% residual stenosis) rates were 25.3% in the stent group and 39.6% in the balloon angioplasty group (p = 0.04). At six months, the event-free survival rates were 81.2% in the stent group and 72.7% in the balloon angioplasty group (p = 0.14), and the repeat revascularization rates were 16.8% and 26.4%, respectively (p = 0.1). At one year, the event-free survival rates were 80.2% in the stent group and 71.8% in the balloon angioplasty group (p = 0.16), and the repeat revascularization rates were 17.8% and 28.2%, respectively (p = 0.1). CONCLUSIONS: In the setting of primary angioplasty for AMI, as compared with a strategy of conventional balloon angioplasty, systematic stenting using the Wiktor stent results in lower rates of angiographic restenosis.

Angioplasty, Balloon↗

Conservative management for an extensive type A aortic dissection complicating coronary angioplasty.

Aortic dissection is a recognized, though rare complication of percutaneous revascularization procedures. We report a case of an extensive type A dissection that occurred during an attempt to recanalize a chronic total occlusion of a right coronary artery. The patient was treated conservatively and was followed for 36 months, during which he remained well. We conclude that, even though surgery remains the preferred option, conservative management could also be considered in certain patients.

Aortic Dissection↗

Stiff hydrophilic glidewire: a useful tool for percutaneous insertion of intraaortic balloon counterpulsation catheters.

Intra-aortic balloon catheters have a central lumen able to accommodate dedicated 0.030" guidewires but not conventional 0.035" guidewires. Due to its extreme lubricity, the 0.035" hydrophilic "glidewire" fits into these catheters and is particularly useful in its stiff, angled version for femoral percutaneous insertion in patients with severe calcific iliac disease.

Catheterization↗

Clinical experience with a new biocompatible phosphorylcholine-coated coronary stent.

AIMS: The BiodivYsio stent is a new stent coated with phosphorylcholine, a biocompatible molecule designed to reduce the formation of thrombus and potentially the risk of restenosis. The feasibility, safety, and efficacy of elective and urgent implantation of this coated coronary stent were prospectively studied. METHODS AND RESULTS: We studied 224 patients who underwent elective (67%) or bail-out implantation of 303 BiodivYsio stents in 286 lesions. Most lesions (62%) had unfavorable characteristics (type B2 or C) and half of them (50%) had thrombus and/or chronic total occlusion. Clinical follow-up was obtained in all patients at one month and in the first 132 patients at six months. Repeat angiography was undertaken in all patients with recurrent ischemia. Successful stent deployment was achieved in 284 lesions (99.3%). One emergency coronary artery bypass graft (CABG) was required. Angiographic success rate was 98.3% (281/286). There was 1 (0.4%) subacute stent thrombosis associated with Q-wave myocardial infarction and two (0.9%) in-hospital deaths. Reference vessel diameter was 2.82 +/- 0.32 mm. Minimum luminal diameter (MLD) increased from 0.38 +/- 0.25 mm to 2.97 +/- 0.35 mm and diameter stenosis decreased from 83.8 +/- 12.1% to 5.8 +/- 9.7%. Clinical restenosis rate was 6.1% (8/132 patients) at 6-month follow-up. Target vessel revascularization rate at 6-month follow-up was 5.4%. CONCLUSIONS: This initial clinical experience indicates that the implantation of stents coated with phosphorylcholine appears to be safe and efficacious in the treatment of complex coronary lesions and is associated with an extremely low target vessel revascularization rate.

Adult↗

Direct stent implantation without predilatation using the MultiLink stent.

The standard coronary stent implantation technique requires routine predilatation of the target lesion with a balloon catheter. In this study, we prospectively studied the feasibility and efficiency of elective coronary stent implantation without predilatation. In 94 patients who presented with various ischemic syndromes, direct implantation of 100 balloon expandable ACS MultiLink stents (7 over-the-wire, 93 rapid exchange) was attempted in 100 coronary lesions selected to have favorable characteristics. The stent crossed the lesion without predilatation in 97 cases (97%) and was successfully deployed in 93 (95.8%). In 4 patients, adjunctive high-pressure postdilatation was necessary to achieve optimal stent expansion. Reference vessel diameter was 3.12+/-0.77 mm and lesion length 8.8+/-2.7 mm. Minimal luminal diameter increased from 0.95+/-0.38 mm to 2.98+/-0.28 mm and diameter stenosis decreased from 71+/-11% to 8+/-11% after stenting. One occlusive dissection was treated by a second stent. There were no major in-hospital complications. At 1 month follow-up, 1 subacute thrombotic occlusion occurred. These results indicate that in a carefully selected coronary lesion subset, elective stent implantation without predilatation can be safely and effectively performed. The long-term results of this approach and possible advantages over the conventional implantation techniques remain unclear and need to be evaluated in further clinical studies.

Aged↗

Preliminary experience with the NIR coronary stent.

We prospectively studied 223 patients (288 lesions) who underwent elective or bail out implantation of 309 NIR stents (Scimed, Boston Scientific Corporation, Galway, Ireland). Most lesions (68.4%) had unfavorable characteristics (type B2 or C). Primary success in stent deployment was achieved in 305 (98.6%). There was no Q-wave myocardial infarction. Emergency coronary artery bypass grafting (CABG) was required in 1 patient and 1 death occurred. Subacute thrombosis rate was 0.4%. Reference diameter was 2.65+/-0.67 mm. Minimum luminal diameter (MLD) increased from 0.62+/-0.45 to 2.69+/-0.57 mm and diameter stenosis decreased from 78.3+/-13.4% to 12.7+/-5.9%. Clinical follow-up was performed in the first 135 patients for 5.3+/-1.6 months and repeat angiography was undertaken in 35 (16%) with recurrence of symptoms at 4.6+/-1.3 months. Clinical restenosis rate was 9.6%. We conclude that the NIR coronary stent exhibits favorable performance characteristics and appears to be safe and efficacious in the treatment of coronary lesions even in the presence of high-risk characteristics.

Adult↗

Recanalization of chronic coronary occlusions using a new hydrophilic guidewire.

Chronic total occlusion remains a relative contraindication and the main cause of failure of coronary angioplasty. Previously available hydrophilic guidewires had numerous limitations. The Crosswire is a new 0.014" hydrophilic nitinol guidewire which can be accommodated by very-low-profile balloon catheters and has a shapeable and highly radiopaque platinum-iridium coiled tip. This guidewire was used in 55 patients with 56 chronic coronary occlusions in which recanalization by conventional guidewires had failed. Clinical success was 79%. Coronary perforation occurred in two cases, one of them requiring pericardiocentesis for tamponade. These results illustrate the usefulness of this new guidewire in the treatment of chronic total occlusions.

Adult↗

Bilateral internal mammary angiography through a right radial approach: a case report.

This case report demonstrates that bilateral internal mammary angiography through a single right-radial approach is feasible and convenient. It avoids double-brachial or radial artery puncture, is adapted to the variable characteristics of right internal mammary artery origin, and may be considered when the femoral approach is contraindicated.

Aged↗

Preliminary clinical experience with the Bard XT coronary stent.

BACKGROUND: The Bard XT stent is a balloon expandable stent with a new design, consisting of discrete zigzag modules welded onto a flexible longitudinal spine. METHODS: To assess the safety and efficacy of this recently introduced coronary stent, we studied 81 patients (107 lesions) who underwent implantation of 108 such stents (66% elective). RESULTS: Primary success in stent delivery was 97.1% and angiographic success was achieved in all cases. Reference segment diameter was 2.69+/-1.4 mm and average lesion length 10.9 mm. Mean minimal luminal diameter before the procedure was 0.79+/-1.11 mm and increased to 2.55+/-1.09 mm after stenting. Diameter stenosis decreased from 76%+/-24% to 9%+/-12%. One Q wave and 1 non-Q-wave myocardial infarction occurred but no other significant complications were observed. At 1-month follow-up, angiographically documented subacute thrombosis occurred in 2 cases at days 1 and 3. Conclusions These preliminary data suggest that the Bard XT stent has a promising design for the safe and effective treatment of coronary lesions, even in the presence of high-risk clinical and unfavorable angiographic characteristics.

Aged↗

Early deterioration after excimer laser-assisted coronary angioplasty.

Coronary lumen changes after excimer laser coronary angioplasty, after adjunct percutaneous transluminal coronary angioplasty, and at 24 hours after intervention were assessed using quantitative coronary angiography. Lesions treated with this combined technique showed significant early deterioration within 24 hours.

Aged↗

Rotational coronary atherectomy with adjunctive balloon angioplasty: evaluation of lumen enlargement by quantitative angiographic analysis.

To evaluate the mechanisms of lumen enlargement and the respective contributions of rotational coronary atherectomy (RA) and adjunctive percutaneous transluminal coronary balloon angioplasty (PTCA), serial measurements were recorded in 70 consecutive patients by quantitative coronary angiography before RA, after RA, after adjunctive PTCA, and 24 hours later. Minimal luminal diameter (MLD) increased from 0.85 +/- 0.31 mm to 1.42 +/- 0.27 mm (p < 0.001) after RA and to 2.20 +/- 0.46 mm (p < 0.001) after PTCA. Minimal luminal area (MLA) increased from 0.64 +/- 0.50 mm2 to 1.63 +/- 0.60 mm2 (p < 0.001) after RA and to 3.97 +/- 1.68 mm2 (p < 0.001) after PTCA. Both 24-hour MLD and MLA showed a trend toward reduced values (2.07 +/- 0.45 mm and 3.52 +/- 1.70 mm2, respectively) when compared with immediate results after PTCA. The absolute gains in MLD after RA and after PTCA were 0.56 +/- 0.24 mm and 0.79 +/- 0.38 mm, respectively (p < 0.01). The absolute gains in MLA after RA and after PTCA were 0.99 +/- 0.49 mm2 and 2.34 +/- 1.41 mm2, respectively (p < 0.001). The respective contributions of RA and PTCA are highly variable, but in general, balloon dilatation accounts for most of the gain in lumen area and therefore is not an adjunctive but a primary technique.

Aged↗