PubMed Health⌕ Search

Biomedical subjects

X Ronald Zhu

Publications and source records attributed to X Ronald Zhu.

6 recordsLinked to original sources

Reducing metal artifacts in cone-beam CT images by preprocessing projection data.

PURPOSE: Computed tomography (CT) streak artifacts caused by metallic implants remain a challenge for the automatic processing of image data. The impact of metal artifacts in the soft-tissue region is magnified in cone-beam CT (CBCT), because the soft-tissue contrast is usually lower in CBCT images. The goal of this study was to develop an effective offline processing technique to minimize the effect. METHODS AND MATERIALS: The geometry calibration cue of the CBCT system was used to track the position of the metal object in projection views. The three-dimensional (3D) representation of the object can be established from only two user-selected viewing angles. The position of the shadowed region in other views can be tracked by projecting the 3D coordinates of the object. Automatic image segmentation was used followed by a Laplacian diffusion method to replace the pixels inside the metal object with the boundary pixels. The modified projection data were then used to reconstruct a new CBCT image. The procedure was tested in phantoms, prostate cancer patients with implanted gold markers and metal prosthesis, and a head-and-neck patient with dental amalgam in the teeth. RESULTS: Both phantom and patient studies demonstrated that the procedure was able to minimize the metal artifacts. Soft-tissue visibility was improved near or away from the metal object. The processing time was 1-2 s per projection. CONCLUSION: We have implemented an effective metal artifact-suppressing algorithm to improve the quality of CBCT images.

Algorithms↗

Initial experience of FDG-PET/CT guided IMRT of head-and-neck carcinoma.

PURPOSE: The purpose of this study is to evaluate the impact of (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET) fused with planning computed tomography (CT) on tumor localization, which guided intensity-modulated radiotherapy (IMRT) of patients with head-and-neck carcinoma. METHODS AND MATERIALS: From October 2002 through April 2005, we performed FDG-PET/CT guided IMRT for 28 patients with head-and-neck carcinoma. Patients were immobilized with face masks that were attached with five fiducial markers. FDG-PET and planning CT scans were performed on the same flattop table in one session and were then fused. Target volumes and critical organs were contoured, and IMRT plans were generated based on the fused images. RESULTS: All 28 patients had abnormal increased uptake in FDG-PET/CT scans. PET/CT resulted in CT-based staging changes in 16 of 28 (57%) patients. PET/CT fusions were successfully performed and were found to be accurate with the use of the two commercial planning systems. Volume analysis revealed that the PET/CT-based gross target volumes (GTVs) were significantly different from those contoured from the CT scans alone in 14 of 16 patients. In addition, 16 of 28 patients who were followed for more than 6 months did not have any evidence of locoregional recurrence in the median time of 17 months. CONCLUSION: Fused images were found to be useful to delineate GTV required in IMRT planning. PET/CT should be considered for both initial staging and treatment planning in patients with head-and-neck carcinoma.

Adult↗

Multiple regions-of-interest analysis of setup uncertainties for head-and-neck cancer radiotherapy.

PURPOSE: To analyze three-dimensional setup uncertainties for multiple regions of interest (ROIs) in head-and-neck region. METHODS AND MATERIALS: In-room computed tomography (CT) scans were acquired using a CT-on-rails system for 14 patients. Three separate bony ROIs were defined: C2 and C6 vertebral bodies and the palatine process of the maxilla. Translational shifts of 3 ROIs were calculated relative to the marked isocenter on the immobilization mask. RESULTS: The shifts for all 3 ROIs were highly correlated. However, noticeable differences on the order of 2-6 mm existed between any 2 ROIs, indicating the flexibility and/or rotational effect in the head-and-neck region. The palatine process of the maxilla had the smallest right-left shifts because of the tight lateral fit in the face mask, but the largest superior-inferior movement because of in-plane rotation and variations in jaw positions. The neck region (C6) had the largest right-left shifts. The positioning mouthpiece was found effective in reducing variations in the superior-inferior direction. There was no statistically significant improvement for using the S-board (8 out of 14 patients) vs. the short face mask. CONCLUSIONS: We found variability in setup corrections for different regions of head-and-neck anatomy. These relative positional variations should be considered when making setup corrections or designing treatment margins.

Algorithms↗

Intensity-modulated radiation therapy for mesothelioma: impact of multileaf collimator leaf width and pencil beam size on planning quality and delivery efficiency.

PURPOSE: To compare treatment plans for multileaf collimators (MLCs) with different leaf widths and different finite pencil beam (FPB) sizes, to determine the planning quality and delivery efficiency of segmented MLC (SMLC) delivery of intensity-modulated radiation therapy (IMRT) for malignant pleural mesothelioma (MPM). METHODS AND MATERIALS: Computerized tomography images of 10 right-side MPM patients were used for this planning study on a CORVUS treatment-planning system (NOMOS Corporation, Sewickley, PA) for a Varian Millennium 120-MLC (Varian Medical Systems, Palo Alto, CA). Three beam models were used. The first model forced two 0.5-cm MLC leaves to move in tandem to simulate a 1-cm leaf-width MLC and a FPB size of 1 x 1 cm2. The second model used 0.5-cm leaves with a FPB size of 0.5 x 1 cm2 (1 cm in the direction of leaf movement). The third model used 0.5-cm leaves, with a FPB size of 0.5 x 0.5 cm2. For optimization, the same dose constraints and beam parameters were used for each data set. Tissue heterogeneity corrections were used during optimization and dose calculation. Plans were optimized such that the clinical target volume received 50 Gy in 25 fractions. Dose distributions to the target and normal structures were evaluated. The number of monitor units, the number of segments, and delivery times were used to evaluate delivery efficiency. RESULTS: All three beam models could be used for IMRT planning for MPM. The doses to clinical target volume, spinal cord, lung, liver, heart, and contralateral kidney were acceptable with all three beam models. The 0.5 x 0.5-cm2 beam model used the most monitor units (6883 +/- 974 vs. 3332 +/- 406 and 3407 +/- 443 for the 1 x 1-cm2 and 0.5 x 1-cm2 models, respectively) and treated the most segments (4297 +/- 802 vs. 1357 +/- 156 and 1767 +/- 212 for the 1 x 1-cm2 and 0.5 x 1-cm2 models, respectively). The plan generated with the 1 x 1-cm2 model required the least amount of time to deliver. CONCLUSIONS: The quality of the MPM IMRT plans generated with the three beam models presented here was similar; however, the 1 x 1-cm2 model provided the most efficient delivery of MPM IMRT with the CORVUS planning system.

Aged↗

Treatment planning system evaluation for mesothelioma IMRT.

BACKGROUND AND PURPOSE: Malignant pleural mesothelioma (MPM) has been treated with extrapleural pneumonectomy (EPP) followed by IMRT. IMRT improved radiation dose distributions to the complex operative bed, and preliminary results suggested improved local control compared with conventional treatment planning. IMRT was initially developed on the Corvus treatment planning system. Other treatment planning systems are also IMRT-capable. Treatment plans from several systems were compared to determine the feasibility of using IMRT in a multi-institution trial. PATIENTS AND METHODS: Treatment plans were generated on Corvus, Eclipse, and Pinnacle for a right-sided MPM after EPP using 6 MV X-rays. Tissue heterogeneity corrections were used in dose calculation. Plans were optimized such that the clinical target volume received 50 Gy in 25 fractions. Dose distributions to the target and normal structures were evaluated. The treatment time and delivery efficiency were estimated. RESULTS: Treatment plans could be calculated by all three planning systems without system failure. Larger volumes received 60Gy in Corvus plans (40%, 17% and 8% for Corvus, Pinnacle and Eclipse, respectively). Corvus used the most monitor units (2786 versus 1451 and 1813 for Pinnacle and Eclipse), and treated the most segments (1050 versus 267 and 173 for Pinnacle and Eclipse). Doses to spinal cord, lung, heart, liver, and contralateral kidney were acceptable for all planning systems. CONCLUSIONS: IMRT plans can be calculated for MPM targets by at least three commonly available treatment planning systems. Pinnacle- and Eclipse-based plans seem more efficient, and may be delivered in a shorter time than Corvus-based plans.

Aged↗

Planning quality and delivery efficiency of sMLC delivered IMRT treatment of oropharyngeal cancers evaluated by RTOG H-0022 dosimetric criteria.

The time required to deliver intensity-modulated radiation therapy (IMRT) treatments can be significantly longer than conventional treatments, especially for the segmented multileaf collimator (sMLC) delivery system with a large record and verification (R&V) overhead. In this work, we evaluate the impact of the number of intensity-modulated beams (IMBs) and the number of intensity levels (ILs) on the quality and delivery efficiency of IMRT plans, generated by the Corvus planning system for sMLC delivery on a Siemens LINAC with the Lantis R&V system. Detailed studies were performed for three image data sets of previously treated oropharyngeal patients. Treatment plans for patient 1 were developed using 5, 7, 9, or 15 evenly spaced axial IMBs as well as one with 7 axial IMBs whose directions were user-selected, each using ILs of 3, 5, 10, or 20. For patients 2 and 3, plans with 15 IMBs and 20 ILs were not attempted. A total of 42 plans were developed using three oropharyngeal cancer CT image data sets. Plan quality was evaluated by assessing compliance with the Radiation Therapy Oncology Group (RTOG) H-0022 protocol criteria and the physician's clinical judgment. Plan efficiency was accessed by the number of segments of each plan. We found that for our treatment-planning and delivery system, an IMRT plan that uses a moderate number of IMBs and ILs, such as 7 or 9 IMBs with 3 or 5 ILs, would appear to be the optimal approach when both quality of the plan and delivery efficiency are considered. Based on this study, we have routinely used 9 IMBs with 3 ILs or 7 IMBs with 5 ILs for head and neck patients. A retrospective comparison indicates that delivery efficiency is improved on the order of 30% compared to plans generated with 9 IMBs with 5 ILs.

Body Burden↗