PubMed Health⌕ Search

Biomedical subjects

Xavier Montet

Publications and source records attributed to Xavier Montet.

7 recordsLinked to original sources

Ultrasound diagnosis of anterior iliopsoas impingement in total hip replacement.

Iliopsoas impingement syndrome, an infrequent complication of total hip replacement, has been rarely reported in the radiological literature. It follows chronic friction of the posterior aspect of the iliopsoas muscle and tendon against the acetabular cup, a piece of cement, or cup fixation screws. Clinical findings are non-specific and an imaging modality is required to diagnose the condition. Computed tomography (CT) is considered the gold standard imaging modality in evaluating iliopsoas impingement. We report a case of a patient in which the diagnosis was made by ultrasound and later confirmed by CT.

Aged↗

Kinetics of gadobenate dimeglumine in isolated perfused rat liver: MR imaging evaluation.

PURPOSE: To compare in the entire liver, the hepatic kinetics of gadobenate dimeglumine (Gd-BOPTA) and gadopentetate dimeglumine (Gd-DTPA) and to evaluate the hepatic transport of Gd-BOPTA. MATERIALS AND METHODS: The authors studied both contrast agents in isolated perfused rat livers by measuring the magnetic resonance (MR) signal intensity (SI) in 12 rats, as well as the gadolinium concentrations in hepatic tissues in 42 rats. The intrahepatic transport of Gd-BOPTA was investigated with pharmacologic antagonism by using bromosulfophthalein. MR imaging was performed at 1.5 T with a fast gradient-echo T1-weighted MR sequence. RESULTS: The hepatic kinetics based on the MR SI measured over time showed a rapid steady state during Gd-DTPA perfusion, while the SI continuously increased during the 30-minute Gd-BOPTA perfusion period. The pharmacokinetic modeling indicated that the half-lives of Gd-DTPA entry and exit were identical (mean, 1.3 minutes +/- 0.9 [standard error of mean]) and shorter than those observed with Gd-BOPTA (P <.001). The uptake of Gd-BOPTA was faster (mean half-life, 4.8 minutes +/- 0.3) than the washout (mean half-life, 17.5 minutes +/- 2.8) (P =.001). The combined perfusion of bromosulfophthalein and Gd-BOPTA decreased the SI enhancement in comparison with the perfusion of Gd-BOPTA alone (mean, 0.56 +/- 0.03 vs 2.54 +/- 0.39, P <.001). The entry and exit kinetic parameters obtained during the perfusion of Gd-BOPTA plus bromosulfophthalein were identical and comparable to those obtained during Gd-DTPA perfusion (P =.95). Acute bile duct ligation did not interfere with the uptake of Gd-BOPTA in hepatocytes, but it slowed down the excretion by approximately 50%. Measurements of gadolinium concentrations in hepatic tissues confirmed these findings. CONCLUSION: In the liver, the hepatospecific contrast agent Gd-BOPTA enters into hepatocytes likely through the organic anion transporting peptide 1.

Animals↗

Inflow effect correction in fast gradient-echo perfusion imaging.

The purposes of this study were to assess the extent of the inflow effect on signal intensity (SI) for fast gradient-recalled-echo (GRE) sequences used to observe first-pass perfusion, and to develop and validate a correction method for this effect. A phantom experiment with a flow apparatus was performed to determine SI as a function of Gd-DTPA concentration for various velocities. Subsequently a flow-sensitive calibration method was developed, and validated on bolus injections into an open-circuit flow apparatus and in vivo. It is shown that calibration methods based on static phantoms are not appropriate for accurate signal-to-concentration conversion in images affected by high flow. The flow-corrected calibration method presented here can be used to improve the accuracy and robustness of the arterial input function (AIF) determination for tissue perfusion quantification using MRI and contrast media.

Blood Flow Velocity↗

Imaging of fractures of the lateral process of the talus, a frequently missed diagnosis.

Although if fractures of the lateral process of the talus (LPT) have been considered rare the widespread diffusion in snowboard practice has resulted in a dramatic increase in their frequency. If unrecognized they can result in secondary osteoarthritis of the ankle and/or talo-calcaneal joints and chronic pain and stiffness. Due to the complex anatomy of the region, these fractures are difficult to detect by standard radiographs. A high degree of suspicion is then necessary to diagnose them. Once suspected on the basis of physical examination and/or non concluding radiographs, computed tomography (CT) is the best modality to confirm the diagnosis and accurately appreciate the number of the fragments and their position which have therapeutic consequences (medical vs. surgical treatment). A better knowledge of these lesions seems necessary to the general radiologist to allow an early diagnosis in order to avoid chronic sequel. The purpose of this article is to report three additional cases of LPT fractures and discuss their pathogenesis, diagnosis and treatment.

Adult↗

Noninvasive measurement of absolute renal perfusion by contrast medium-enhanced magnetic resonance imaging.

OBJECTIVE: The aim of this study was to validate the quantification of absolute renal perfusion (RP) determined by dynamic magnetic resonance imaging (MRI) and contrast media using an experimental model in the rabbit and a transit-timed ultrasound flow probe around the left renal artery as comparison. MATERIAL AND METHODS: An MR-compatible ultrasonic time-of-flight flow-probe was placed around the left renal artery in 9 New Zealand white rabbits. Absolute RP in basal state, after mechanical renal artery stenosis, intravenous dopamine, angiotensin II, or colloid infusion was measured using dynamic MRI and intravenous injection of gadoteridol. The results were correlated to the renal artery flow measured inside the magnet with the transit-timed flow-probe. For the signal intensity concentration conversion, we applied different calibrations according to various velocities measured in the aorta by a phase contrast sequence to correct for inflow effect. MRI-derived RP (in mL/min) was calculated by the maximum upslope method, where RP/volume was defined as the ratio of the cortex contrast enhancement slope over the maximum of the arterial input function determined in the aorta. RESULTS: Reproducible arterial and renal transit curve with excellent contrast to noise ratio were obtained. The MRI derived perfusion was systematically underestimated by comparison to the ultrasonic transit-timed flow-probe but was linearly correlated with these measures (r = 0.80, P < 0.001). CONCLUSIONS: Using a flow-sensitive calibration, an accurate arterial input function can be measured from the blood MR signal and used in a realistic model to assess the RP. There was a good correlation between the MR-derived RP and the renal artery blood flow measured by the flow-meter. This experimental study validates absolute RP quantification by MRI and contrast media injection and justifies further clinical studies.

Animals↗

Sonographic and MRI appearance of tensor fasciae suralis muscle, an uncommon cause of popliteal swelling.

A 20-year-old white man presented with a localized unilateral swelling in the popliteal fossa. Ultrasound (US) showed the presence of an accessory muscle, the tensor fasciae suralis. The muscle was located in the proximal portion of the popliteal fossa, superficial to the medial head of the gastrocnemius. Its long tendon extended inferiorly to join the Achilles tendon. Magnetic resonance images correlated well with the US findings, confirming the diagnosis. Tensor fasciae suralis muscle is a rare cause of popliteal swelling and must be differentiated from other masses. Both US and magnetic resonance imaging can diagnose it but we suggest US as the first-line technique in its evaluation.

Adult↗