Xiang-li Liu

Publications and source records attributed to Xiang-li Liu.

2 recordsLinked to original sources

[A quantitative study of anterior chamber angle with ultrasound biomicroscopy after cataract surgery with phacoemulsification and foldable intraocular lenses implantation].

OBJECTIVE: To study the changes in anterior chamber angle after phacoemulsification and foldable IOL implantation with ultrasound biomicroscopy. METHODS: Small-incision phacoemulsification and foldable IOL implantation were performed in 50 eyes of 46 senior patients, and the changes of anterior chamber angle were determined quantitatively by using ultrasound biomicroscopy before and one month after the surgery. RESULTS: In all patients, the angle was widened significantly one month after surgery (P < 0.01). The measurements of TIA500 (trabecular-iris angle at 500 micro m from the scleral spur), AOD250 (angle-opening distance at 250 micro m from the scleral spur) and AOD500 (angle-opening distance at 500 micro m from the scleral spur) increased significantly after the operation (P < 0.01). The mean post/pre-operative TIA500 ratio, AOD250 ratio and AOD500 ratio were 1.65 (1.12 - 4.91), 1.81 (1.06 - 2.67) and 1.65 (1.01 - 2.76), respectively. A significant negative correlation existed between preoperative and postoperative data. CONCLUSION: Small-incision cataract surgery deepens the anterior chamber and widens anterior chamber angle significantly in senior patients. The narrower the preoperative angle, the higher ratio of post/preoperative ratio found.

Aged↗

[Visual outcome with the array multifocal intraocular lens].

OBJECTIVE: To evaluate the visual outcome of Array IOL, and examine the location of the lens. METHODS: 255 eyes in 196 patients received phaco and IOL implantation were randomized as test group 121 eyes (Array IOL) and case control group 134 eyes (monofocal Hydroview IOL). Postoperative examination included distance and near, uncorrected and corrected visual acuity, refractive results, and measurement of corneal curvature. Follow-up period ranged from three months to one year. RESULTS: Three months after surgery, 97.2% eyes (107/110) in test group with Array IOL had a distance visual acuity >/= 0.5, and in 24.5% (27/110) >/= 1.0. The difference was not significant (P > 0.05). 84.6% eyes (93/110) in test group had an uncorrected near acuity >/= 0.5 and 20.0% (22/110) >/= 1.0. The difference was significant (P < 0.01). The rate of wearing spectacles was 33.3% in test group and 90% in case control group. One month after surgery, 6 eyes in test group with haptic asymmetric location were not affected with visual recovery. The surgery-induced astigmatism in test group was 0.31 D, and no visual impairment appeared in both groups. Posterior capsule opacification was seen in 6 eyes in test group and 12 in case control group. CONCLUSION: The implantation of Array IOL not only has a good distance uncorrected visual acuity, but also with better near visual acuity. Also this surgery is safe, reliable and no special complication-induced.

Adult↗