PubMed Health⌕ Search

Biomedical subjects

Xiangchun Xuan

Publications and source records attributed to Xiangchun Xuan.

13 recordsLinked to original sources

Continuous separation of microparticles by size with direct current-dielectrophoresis.

Direct current-dielectrophoresis (DC-DEP), the induced motion of the dielectric particles in a spatially nonuniform DC electric field, is demonstrated to be a highly efficient method to separate the microparticles by size. The locally nonuniform electric field is generated by an insulating block fabricated inside a polydimethylsiloxane microchannel. The particle experiences a negative DEP (accordingly a repulsive force) at the corners of the block, where the local electric-field strength is the strongest. Thus, the particle deviates from the streamline and the degree of deviation is dependent on the DEP force (i.e., the particle size). Combined with the electrokinetic flow, mixed polystyrene particles of a few micrometers difference in diameter can be continuously separated into distinct reservoirs. For separating target particles of a specific size, it is required to simply adjust the voltage outputs of the electrodes. A numerical model based on the Lagrangian tracking method is developed to simulate the particle motion and the results showed a reasonable agreement with the experimental data.

Electrophoresis↗

Joule heating effects on separation efficiency in capillary zone electrophoresis with an initial voltage ramp.

An analytical model is developed to quantify the Joule heating effects on the separation efficiency in CZE with an initial voltage ramp. This model considers the temporal variations of nonuniform temperature and flow fields in the course of voltage ramping. The temperature dependence of electrical conductivity, dynamic viscosity, and mass density of the fluid is also taken into account. We demonstrate that the application of an initial voltage ramp delays the development of pressure-driven flows induced passively by the axial temperature gradients. The thermal dispersion is thus significantly reduced, resulting in a higher theoretical plate number in CZE. Such improvement in the separation efficiency is apparent in noncoated capillaries at high electric fields with an appropriate voltage ramp-up time. These predictions are consistent with previous observations in both aqueous and nonaqueous CZE that took place in uncoated capillaries. In coated capillaries where the EOF is suppressed, however, our model predicts a lower plate number in the presence of an initial voltage ramp.

Electricity↗

Electrokinetic transport of charged solutes in micro- and nanochannels: the influence of transverse electromigration.

The accurate prediction of electrokinetic migration velocity and dispersion is crucial to separating electrophoretically charged solutes in micro- or nanochannels. In this paper, we investigate numerically the influence of transverse electromigration (TEM) on the solute electrokinetic transport in a series of micro- and nanochannels. The TEM, often ignored in previous studies, is demonstrated to significantly affect the solute migration velocity in nanochannels and the electrokinetic dispersion in microchannels. This is because the TEM can force either positively charged solutes into or negatively charged solutes out of the electrical double layer that forms adjacent to the negatively charged channel wall and contains the velocity gradients. Analytical solutions are also derived for characterizing the electrokinetic transport of charged solutes in nanochannels, which has been validated to be in good agreement with the numerical simulation. Moreover, we demonstrate that the proposed analytical formula for the solute migration velocity actually applies to channels of any size.

Electrophoresis↗

DC-dielectrophoretic separation of microparticles using an oil droplet obstacle.

A new dielectrophoretic particle separation method is demonstrated and examined in the following experimental study. Current electrodeless dielectrophoretic (DEP) separation techniques utilize insulating solid obstacles in a DC or low-frequency AC field, while this novel method employs an oil droplet acting as an insulating hurdle between two electrodes. When particles move in a non-uniform DC field locally formed by the droplet, they are exposed to a negative DEP force linearly dependent on their volume, which allows the particle separation by size. Since the size of the droplet can be dynamically changed, the electric field gradient, and hence DEP force, becomes easily controllable and adjustable to various separation parameters. By adjusting the droplet size, particles of three different diameter sizes, 1 microm, 5.7 microm and 15.7 microm, were successfully separated in a PDMS microfluidic chip, under applied field strength in the range from 80 V cm-1 to 240 V cm-1. A very effective separation was realized at the low field strength, since the electric field gradient was proved to be a more significant parameter for particle discrimination than the applied voltage. By utilizing low strength fields and adaptable field gradient, this method can also be applied to the separation of biological samples that are generally very sensitive to high electric potential.

Electrophoresis, Microchip↗

Wall effects on electrophoretic motion of spherical polystyrene particles in a rectangular poly(dimethylsiloxane) microchannel.

The wall effects on electrophoretic motion of spherical polystyrene particles in a rectangular poly(dimethylsiloxane) microchannel were studied experimentally. It is found that the particle electrophoretic velocity is insensitive to the trajectory between the channel sidewalls, consistent with the theoretical prediction. We also demonstrate that the electrophoretic motion of larger particles along the channel centerline is more viscously retarded by the sidewalls of a narrower channel. This observation is well predicted by incorporating the analytical models for the particle electrophoresis along the centerline of a slit channel and along the axis of a cylindrical pore.

Journal Article↗

Near-wall electrophoretic motion of spherical particles in cylindrical capillaries.

In this paper, near-wall electrophoretic motion of spherical particles in cylindrical capillaries was experimentally investigated. It is demonstrated that same-sized particles move faster in smaller capillaries. This observation verifies the theoretical prediction of the wall enhancing effect in our recent paper (C. Ye, X. Xuan, D. Li, Microfluid. Nanofluid. 1 (2005)). Our experiments show that this wall enhancing effect becomes more significant when the size difference between particle and capillary becomes smaller and when a dilute electrolyte solution (i.e., thicker electric double layer) is used.

Journal Article↗

Electroosmotic flow in microchannels with arbitrary geometry and arbitrary distribution of wall charge.

General solutions are developed for direct current (DC) and alternating current (AC) electroosmotic flows in microfluidic channels with arbitrary cross-sectional geometry and arbitrary distribution of wall charge (zeta potential). The applied AC electric field can also be of arbitrary waveform. By proposing a nondimensional time scale varpi defined as the ratio of the diffusion time of momentum across the electric double-layer thickness to the period of the applied electric field, we demonstrate analytically that the Helmholtz-Smoluchowski electroosmotic velocity is an appropriate slip condition for AC electroosmotic flows in typical microfluidic applications. With this slip condition approach, electroosmotic flows in rectangular and asymmetric trapezoidal microchannels with nonuniform wall charge, as examples, are investigated. The unknown constants in the proposed general solutions are numerically determined with a least-squares method through matching the boundary conditions. We find that the wall charge affects significantly the electroosmotic flow while the channel geometry does not. Moreover, the flow feature is characterized by another nondimensional time scale Omega defined as the ratio of the diffusion time of momentum across the channel hydraulic radius to the period of the applied electric field. The onset of phase shift between AC electroosmotic velocity and applied electric field is also examined analytically.

Journal Article↗

Accelerated particle electrophoretic motion and separation in converging-diverging microchannels.

Accelerated particle electrophoretic motions were visualized in converging-diverging microchannels on poly(dimethylsiloxane) chips. The accelerated particle electrophoretic separation is highly desirable in on-chip flow cytometry and high-speed electrophoresis. The effects of electric field, particle size, particle trajectory, and channel structure on the particle electrophoretic motion are examined. We find that the ratio of the particle velocity in the throat to that in the straight channel is significantly lower than their cross-sectional area ratio. This discrepancy may be attributed to the locally higher electric field around the two poles of a particle, as compared to other regions inside the microchannel. We also find that the particle velocity ratio is increased for smaller particles moving through symmetric converging-diverging channels under lower electric fields. These variations may be attributed to the negative dielectrophoretic force that is generated by the nonuniform electric field in the converging-diverging section. In addition, we find that particle trajectory has insignificant influences on the maximum velocity ratio obtained in the throat.

Journal Article↗

Analytical study of Joule heating effects on electrokinetic transportation in capillary electrophoresis.

Electric fields are often used to transport fluids (by electroosmosis) and separate charged samples (by electrophoresis) in microfluidic devices. However, there exists inevitable Joule heating when electric currents are passing through electrolyte solutions. Joule heating not only increases the fluid temperature, but also produces temperature gradients in cross-stream and axial directions. These temperature effects make fluid properties non-uniform, and hence alter the applied electric potential field and the flow field. The mass species transport is also influenced. In this paper we develop an analytical model to study Joule heating effects on the transport of heat, electricity, momentum and mass species in capillary-based electrophoresis. Close-form formulae are derived for the temperature, applied electrical potential, velocity, and pressure fields at steady state, and the transient concentration field as well. Also available are the compact formulae for the electric current and the volume flow rate through the capillary. It is shown that, due to the thermal end effect, sharp temperature drops appear close to capillary ends, where sharp rises of electric field are required to meet the current continuity. In order to satisfy the mass continuity, pressure gradients have to be induced along the capillary. The resultant curved fluid velocity profile and the increase of molecular diffusion both contribute to the dispersion of samples. However, Joule heating effects enhance the sample transport velocity, reducing the analysis time in capillary electrophoretic separations.

Electrophoresis, Capillary↗

Band-broadening in capillary zone electrophoresis with axial temperature gradients.

It is widely accepted that Joule heating effects yield radial temperature gradients in capillary zone electrophoresis (CZE). The resultant parabolic profile of electrophoretic velocity of analyte molecules is believed to increase the band-broadening via Taylor-Aris dispersion. This typically insignificant contribution, however, cannot explain the decrease in separation efficiency at high electric fields. We show that the additional band-broadening due to axial temperature gradients may provide the answer. These axial temperature variations result from the change of heat transfer condition along the capillary, which is often present in CZE with thermostating. In this case, the electric field becomes nonuniform due to the temperature dependence of fluid conductivity, and hence the induced pressure gradient is brought about to meet the mass continuity. This modification of the electroosmotic flow pattern can cause significant band-broadening. An analytical model is developed to predict the band-broadening in CZE with axial temperature gradients in terms of the theoretical plate height. We find that the resultant thermal plate height can be very high and even comparable to that due to molecular diffusion. This thermal plate height is much higher than that due to radial temperature gradients alone. The analytical model explains successfully the phenomena observed in previous experiments.

Electrophoresis, Capillary↗

Focused electrophoretic motion and selected electrokinetic dispensing of particles and cells in cross-microchannels.

The electrokinetic focusing and the resultant accelerated electrophoretic motion of polystyrene particles and red blood cells were visualized in microfluidic cross-channels. The experimentally measured width of the focused stream and the measured velocity increase of particles and cells at different voltage ratios follow the proposed analytical formula within the experimental error. The attained velocity increase is insensitive to the particle size, particle property (i.e., particle or cell), and particle trajectory. By solving the electrical potential field in the cross-channel at the experimental conditions, we demonstrate that the squeezed electrical field lines in the channel intersection determine the shape of the focused stream, and the nonuniform distribution of axial electrical field strength underlies the variation of particle/cell electrophoretic velocity through the focusing region. However, the dielectrophoretic force resulting from the nonuniform electrical field in the intersection seems to push the acceleration region of particles and cells slightly in the downstream direction. We have also achieved the single particle/cell dispensing by instantly triggering an electrical pulse perpendicular to the focused particulate flow in a double-cross microchannel. The electrokinetic manipulation of particle/cell in microchannels demonstrated in this work can be used for developing integrated lab-on-a-chip devices for studies of cells.

Animals↗

Electroosmotic flow with Joule heating effects.

Electroosmotic flow with Joule heating effects was examined numerically and experimentally in this work. We used a fluorescence-based thermometry technique to measure the liquid temperature variation caused by Joule heating along a micro capillary. We used a caged-fluorescent dye-based microfluidic visualization technique to measure the electroosmotic velocity profile along the capillary. Sharp temperature drops close to the two ends and a high-temperature plateau in the middle of the capillary were observed. Correspondingly, concave-convex-concave velocity profiles were observed in the inlet-middle-outlet regions of a homogeneous capillary. These velocity perturbations were due to the induced pressure gradients resulting from axial variations of temperature. The measured liquid temperature distribution and the electroosmotic velocity profile along the capillary agree well with the predictions of a theoretical model developed in this paper.

Journal Article↗

Effects of liquid conductivity differences on multi-component sample injection, pumping and stacking in microfluidic chips.

As an increasing number of processes are being integrated into Lab-on-a-chip devices, there is an increasing need for flexible and accurate sample manipulation techniques for effective transport and separation. Conductivity differences between running buffer and analyte samples can arise as a product of on-chip processing, or by design. The two situations studied here are sample pumping (where bulk transport is increased and separation of charged analytes is delayed using a relatively high conductivity sample), and sample stacking (where bulk transport is decreased and separation of charged analytes is expedited using a relatively low conductivity sample). A recently developed dynamic loading method for on-chip sample injection in a straight-cross channel configuration is applied here to both pumping and stacking cases. A key characteristic of the dynamic loading method is the ability to inject samples of high concentration density and uniformity of any length. By employing the conductivity differences alone, the effectiveness of either sample transport or sample separation are shown to improve over the uniform conductivity case. Then it is demonstrated that increasing the sample length, through dynamic loading, greatly increases the effectiveness of sample pumping, evidenced in an eight-fold increase in peak height as well as a decrease in total sample length at a downstream detector. Dynamic loading in the sample stacking case was shown to also increase peak intensity height (three-fold) in rapid separations. These results demonstrate that the dynamic loading technique, used in conjunction with strategic conductivity differences, significantly extends the capabilities of microfluidic chips.

Journal Article↗