PubMed Health⌕ Search

Biomedical subjects

Xiangfeng Wu

Publications and source records attributed to Xiangfeng Wu.

2 recordsLinked to original sources

Bayesian optimal designs for a quantal dose-response study with potentially missing observations.

In a dose-response study, there are frequently multiple goals and not all planned observations are realized at the end of the study. Subjects drop out and the initial design can be quite different from the final design. Consequently, the final design can be inefficient. Single- and multiple-objective Bayesian optimal designs that account for potentially missing observations in quantal response models were recently proposed in Baek (2005). In this work, we investigate the efficiencies of the conventional optimal designs that do not incorporate potential missing information relative to our proposed designs. Furthermore, we examine the impact of restricted dose range on the resulting optimal designs. As an application, we used missing data information from a study by Yocum et al. (2003) to design a study for estimating dose levels of tacrolimus that will result in a certain percentage of rheumatoid arthritis patients having an ACR20 response at 6 months.

Algorithms↗

Determination of oleanolic acid and ursolic acid in cornel by cyclodextrin-modified micellar electrokinetic chromatography.

A cyclodextrin-modified micellar electrokinetic chromatography (CD-MEKC) method was established for the determination of oleanolic acid and ursolic acid in cornel. The two components were separated in the running buffer of 40 mmol/L sodium borate containing 5% methanol, 25 mmol/L SDS and 15 mmol/L hydroxypropyl-beta-cyclodextrin (HP-beta-CD). The applied voltage was 24 kV. The wavelength of detection was 200 nm. The temperature was kept at 25 C. Cinnamic acid was used as the internal standard. The analytical performance of the method was tested with respect to linearity, precision and recovery. The calibration curves were linear in the range of 10.15-243.6 microg/mL, r=0.9993 (oleanolic acid) and 10.07-241.7 microg/mL, r=0.9994 (ursolic acid); the intra-day precision (RSD) was less than 3.7% (oleanolic acid) and 4.1% (ursolic acid); the inter-day precision (RSD) was less than 4.2% (oleanolic acid) and 4.9% (ursolic acid). The limits of detection were 1.6 microg/mL for both components. The method proved to be sensitive, rapid, accurate and suitable for the determination of oleanolic acid and ursolic acid in cornel.

Chromatography, Micellar Electrokinetic Capillary↗