Large-bore particle-entrapped monolithic precolumns prepared by a sol-gel method for on-line peptides trapping and preconcentration in multidimensional liquid chromatography system for proteome analysis.

The present report describes the preparation and characterization of large-bore particle-entrapped monolithic precolumns, which are suitable for incorporation into a two-dimensional liquid chromatography (2D-LC) system for proteome analysis. The fritless precolumns with different inner diameter (i.d.) (320 and 530 microm) were rapidly and successfully prepared by entrapping octadecylsilica (ODS) particles (5 microm, 300 A) prepacked into fused silica capillaries with a sol-gel network, which was formed by hydrolysis and polycondensation of methyltriethoxysilane (MTES). By optimizing the composition of the sol solution, the resulting large-bore monolithic precolumns of 5 mm length allow a flow rate of 20 microL/min loading buffer at a reasonable low back pressure of 25 bar or less and are capable of withstanding up to 300 bar inlet pressure. Scanning electron micrograms of the precolumns profile showed that the evolving sol-gel network joined particles to each other and onto the column wall, and no cracking or shrinkage of the column bed was observed even in 530 microm-i.d. capillary. The performance of the particle-entrapped monolithic precolumns used for preconcentration and desalting of proteolytic digest was evaluated by on-line coupling the large-bore precolumns with a capillary reversed-phase liquid chromatographic (RPLC) column followed by UV detection. The laboratory-made monolithic precolumns with 320 and 530 microm i.d. were characterized by using BSA tryptic digest or peptide standards as the analytes with respect to sample loading capacity, linearity, recovery and reproducibility, etc. The results indicate that the large-bore and short precolumns (5 mm x 320 microm i.d. or 5 mm x 530 microm i.d.) allow sample fast loading at a flow rate of 30 or 60 microL/min. The precolumns also have a mass loading capacity for BSA peptides of about 70 microg and for standard peptides of about 80 microg. Good linear calibration curves (R2 > 0.99) were obtained and the limits of detection (signal-to-noise ratio, S/N = 3) were improved by more than 60-fold and were between 0.53 and 1.32 ng/microL even with a UV absorbance detector. The total recovery was found to be approximately 90-100% for BSA digest and standard peptides. The day-to-day relative standard deviation (RSD) values for recoveries of BSA peptides on a single precolumn ranged from 4.66 to 7.56% and 2.68 to 3.05% for precolumn back pressure, while the column-to-column RSD values were 3.51-6.13% and 1.22-1.26% for recoveries of BSA peptides and precolumn back pressure, respectively. With good precolumn reproducibility, no significant degradation or decrease in precolumn performance was showed even after approximately 150 preconcentration/desorption cycles. The precolumns also proved to be resistant to salt buffer with high concentration and low-pH mobile phase. The large-bore particle-entrapped monolithic precolumns will be further used in a high-throughput 2D-LC array system coupled with tandem matrix assisted laser desorption/ionization-time of flight-time of flight-mass spectrometry (MALDI-TOF-TOF-MS) detection for proteome analysis.

Calibration↗

Rapid determination of C6-aldehydes in tomato plant emission by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization.

A simple, rapid, sensitive, and solvent-free method was developed for determination of plant-signalling compounds, the three C6-aldehydes hexanal, (Z)-3-hexenal, and (E)-2-hexenal, in tomato plant emission by gas chromatography-mass spectrometry (GC-MS) and solid-phase microextraction (SPME) with on-fiber derivatization. In this method, O-2,3,4,5,6-(pentafluorobenzyl)hydroxylamine (PFBHA) in aqueous solution was first headspace adsorbed onto a 65 microm poly(dimethylsiloxane)/divinylbenzene (PDMS/DVB) fiber at 25 degrees C for 5 min, and then the fiber with adsorbed PFBHA was used for headspace extraction of tomato plant emission at 25 degrees C for 6 min. Finally, the resulting oximes adsorbed on the fiber were desorbed and analyzed by GC-MS. Extraction conditions and method validation were studied. The proposed method had low detection limit values for the three aldehydes from 0.1 to 0.5 ng/L and good precision (RSD less than 10%). In this work, the method was applied to investigation of tomato plant defense response to Helicoverpa armigera.

Adsorption↗

Rapid determination of acetone in human blood by derivatization with pentafluorobenzyl hydroxylamine followed by headspace liquid-phase microextraction and gas chromatography/mass spectrometry.

In the current work, a simple, rapid, accurate and inexpensive method was developed for the determination of acetone in human blood. The proposed method is based on derivatization with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA), followed by headspace liquid-phase microextraction (HS-LPME) and gas chromatography/mass spectrometry (GC/MS). In the present method, acetone in blood samples was derivatized with PFBHA and acetone oxime formed in several seconds. The formed oxime was enriched by HS-LPME using the organic solvent film (OSF) formed in a microsyringe barrel as extraction interface. Finally, the enriched oxime was analyzed by GC/MS in electron ionization (EI) mode. HS-LPME parameters including solvent, syringe plunger withdrawal rate, sampling volume, and extraction cycle were optimized and the method reproducibility, linearity, recovery and detection limit were studied. The proposed method was applied to determination of acetone in diabetes blood and normal blood. It has been shown that derivatization with HS-LPME and GC/MS is an alternative method for determination of the diabetes biomarker, acetone, in blood samples.

Acetone↗

A new analysis method with GC or GC-MS for the quick detection of pesticide residues in vegetables.

A new analytical method for gas chromatography (GC) or GC-mass spectrometry (MS) using the direct sampling technique is described. This direct sampling technique, which bypasses the conventional complicated sample pretreatment process, is applicable to cases of fast detection of pesticide residues in foods and large-scale screening of samples by portable GC in field detection. By a direct sampling technique, the vegetable sample is ground into paste, and 30 mg is placed directly into the evaporating chamber for GC-MS identification and quantitation (by full-scan mode). The GC column used is an HP-5 (30.0-m x 250-microm x 0.25-microm, 5% phenyl methyl siloxane). Chlorpyrifos, bromophos, fenpropathrin, gamma-666, and pp'-DDT are chosen to represent organophosphorus, pyrethrins, and organochlorine pesticides because they are chief objects of the detection of pesticide residues in vegetables. Rape, a common and mass-consumed vegetable in China, is chosen as the sample in this study. The detection limits for these pesticides by the full-scan mode are all below the maximum pesticide residue limit of vegetables set by the Ministry of Agriculture of China, and the reproducibility of this method is acceptable. This analysis method is proven to be simple, quick, and reliable and is suitable for multipesticide residues analysis of vegetables. It can also be used in the analysis of vegetable components and signal chemicals.

Chromatography, Gas↗

[Analyze the role of endoscopic operation in the cerebrospinal fluid rhinorrhea repair].

OBJECTIVE: To explore the effect of the different operative methods on the results with endoscopy in the cerebrospinal fluid rhinorrhea according to different location and different size. METHOD: All clinical records and data were studied retrospectively, compare repair measure under different size and different location of fistula. RESULT: (1) Size of fistulas: 1 mm x 1 mm - 20 mm x 20 mm; (2) Repair methods: 2 cases were repaired by "Bath-plug" method, 10 by onlay, 18 by underlay, and 1 by "Button with fascia". CONCLUSION: (1) The suitable repair methods were selected according to size and location. Underlay is superior to resist intracranial pressure and better for middle size fistula. Onlay is simple and fit to small fistula. "Bath-plug" method was more reliable for the small-middle size fistula. "Button with fascia" was more suitable to large size fistula. (2) Advantages of the endoscopic technique include exact identification of the site of the dural tear, excellent field of vision, less complication and precise placement of graft.

Cerebrospinal Fluid Rhinorrhea↗

[Nano flow multidimensional liquid chromatography for proteome analysis of rat liver].

A nano flow comprehensive multidimensional liquid chromatography was developed. By using this separation platform, complex samples can be injected, desalted, separated and analyzed in complete automatization. Coupling of the strong cation-exchange (SCX) with capillary reversed-phase liquid chromatography (cRPLC) is described for proteomics of rat liver. A step gradient was applied for SCX column, and a linear gradient was applied for RPLC. The flow rate through the nano scale analytical column during the separation process was maintained at 200 nL/min. The peak capacity for the nano-2D-LC was up to 620 under these conditions.

Animals↗

Development of headspace solid-phase microextraction with on-fiber derivatization for determination of hexanal and heptanal in human blood.

Hexanal and heptanal in human blood have been regarded as potential biomarkers of lung cancer. Owing to their high volatilities and activities, it is difficult to accurately measure the two biomarkers. In the current work, headspace solid-phase microextraction (HS-SPME) with on-fiber derivatization technique was developed for quantitative analysis of hexanal and heptanal in human blood. In the proposed method, the two aldehydes in blood were headspace extracted by using a poly (dimethylsiloxane)/divinylbenzene (PDMS/DVB) fiber with O-2,3,4,5,6-(pentafluorobenzyl) hydroxylamine (PFBHA) at 60 degrees C for 8 min. The aldehyde oximes formed on the fiber were desorbed and analyzed by gas chromatography-mass spectrometry (GC-MS). The method validations including detection limit, recovery and precision were studied. It was found that the method provided low detection limits of 0.006 nM for hexanal and 0.005 nM for heptanal, recoveries from 89% to 95% and R.S.D. values less than 8.5%. The present method was applied to quantitative analysis of hexanal and heptanal in normal blood and lung cancer blood. Hexanal concentrations from 7.33 to 15.23 microM and heptanal concentrations from 2.47 to 9.23 microM were found in the lung cancer blood, while both hexanal and heptanal in the control blood were lower than 0.6 microM. This further demonstrated that hexanal and heptanal might be the biomarkers of lung cancer. The experimental results showed that GC-MS and HS-SPME with on-fiber derivatization is a simple, rapid, sensitive and solvent-free method for determination of in hexanal and heptanal human blood.

Aldehydes↗

Rapid determination of essential oil in Acorus tatarinowii Schott. by pressurized hot water extraction followed by solid-phase microextraction and gas chromatography-mass spectrometry.

A simple, rapid, efficient and inexpensive method for the determination of essential oil in a traditional Chinese medicine (TCM), Acorus Tatarinowii Schott. was developed by using pressurized hot water extraction (PHWE) combined with solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS). Acorus Tatarinowii Schott. (0.050 g) was subjected to dynamic extraction with water at 50 bar, 150 degrees C and 1.0 ml/min for 5.0 min, and then the essential oil in the aqueous extract were extracted by SPME fibers at 60 degrees C for 10 min, finally the compounds on the fiber were desorbed and analyzed by GC-MS. The PHWE and SPME parameters were studied. The key active compound of alpha-asarone in the TCM samples from three different growing areas was quantitatively analyzed by external standard method. Compared to steam distillation (SD), the proposed method required little time (only 15 min) to prepare sample. Moreover, little sample mass and no organic solvent was needed. The present method provided good repeatability (R.S.D. less than 13.0%) and recovery (92% for alpha-asarone). It has been shown that PHWE-SPME-GC-MS is an alternative method for determination of essential oils in TCMs and a potential tool for TCM quality assessment.

Acorus↗

Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization.

Analysis of breath acetone has been used as a diagnostic tool for diabetes. Due to its nature of volatility and activity, it is very difficult to accurately measure the concentration of acetone in human breath by gas chromatography-mass spectrometry (GC-MS). To overcome this problem, we developed a new method using GC-MS and solid-phase microextraction (SPME) with on-fiber derivatization to determine acetone in human breath. Breath gas from controls and diabetic patients was collected in 3-l Tedlar bags. O-2,3,4,5,6-(Pentafluorobenzyl) hydroxylamine hydrochloride (PFBHA) in solution was firstly adsorbed on the SPME fiber of 65 microm polydimethylsiloxane-divinylbenzene (PDMS-DVB), and then the fiber was further headspace exposed in exhaled gas in the Tedlar bag at 40 degrees C for 4 min. Finally, the formed acetone oxime on the fiber was desorbed and analyzed by GC-MS. Using external standard method, acetone in the human breath was quantitatively analyzed by measurement of its oxime. The method provided a low detection limit of 0.049 ppbv for acetone in breath, relative standard deviation (R.S.D.) value of 3.4%, excellent accuracy. In addition, the method required simple sample preparation and no organic solvent. Acetone in diabetic breath was found to be higher than 1.71 ppmv, while its concentration in normal breath was lower than 0.76 ppmv. The results show that GC-MS and SPME with on-fiber derivatization is a simple, rapid and sensitive and solvent-free method for determination of low concentration acetone in breath and analysis of breath acetone can be used as supplementary tool for diagnosis of diabetes.

Acetone↗

Investigation of volatile biomarkers in lung cancer blood using solid-phase microextraction and capillary gas chromatography-mass spectrometry.

In the present work, solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) was developed for investigation of lung cancer volatile biomarkers. Headspace SPME conditions (fiber coating, extraction temperature and extraction time) and desorption conditions were optimized and applied to determination of volatiles in human blood. To find the biomarkers of lung cancer, investigation of volatile compounds in lung cancer blood and control was performed by using the present method. Concentrations of hexanal and heptanal in lung cancer blood were found to be much higher than those in control blood. The two molecules of hexanal and heptanal were regarded as biomarkers of lung cancer. By comparison of volatiles in breath and in blood, it is demonstrated that hexanal and heptanal in breath were originated from blood and screening of lung cancer by breath analysis be feasible. These results show that SPME/GC-MS is a simple, rapid and sensitive method very suitable for investigation of volatile disease markers in human blood.

Adult↗

Quality assessment of Flos Chrysanthemi Indici from different growing areas in China by solid-phase microextraction-gas chromatography-mass spectrometry.

Flos Chrysanthemi Indici is a common traditional Chinese medicine (TCM). In this paper, headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry (HS-SPME-GC-MS) was developed for quality assessment of Flos Chrysanthemi Indici from different growing areas in China. SPME parameters such as extraction fibers, extraction temperature, extraction time and sample mass were investigated to achieve identical results to those obtained by the steam distillation (SD). The selected SPME conditions were as follows: SPME fiber coated with 65-microm PDMS/DVB, extraction temperature of 60 degrees C, extraction time of 30 min and sample mass of 1.0 g. Furthermore, four active compounds (eucalyptol, camphor, borneol and bornyl acetate) presented in the TCM were applied to evaluating the quality of Flos Chrysanthemi Indici from 20 various areas. The quality assessment was successfully performed to compare the similarity value (S) between different sample vector of Flos Chrysanthemi Indici and the standard profile vector (SPV). The results showed that the proposed HS-SPME-GC-MS was an alternative technique for quality assessment of Flos Chrysanthemi Indici samples.

China↗

Rapid determination of acetone in human plasma by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization.

Acetone is an important volatile disease marker. Due to its nature of activity and volatility, it is a difficult task to measure the concentration of acetone in biological samples with accuracy. In this paper, we developed a novel method for determination of trace amount acetone in human plasma by solid-phase microextraction technique with on-fiber derivatization. In this method, the poly(dimethylsiloxane)/divinylbenzene (PDMS/DVB) fiber was used and O-2,3,4,5,6-(pentafluorobenzyl) hydroxylamine hydrochloride (PFBHA) was first loaded on the fiber. Acetone in plasma sample was agitated into headspace and extracted by solid-phase microextraction (SPME) fiber and subsequently derivatized with PFBHA on the fiber. Acetone oxime was analyzed by gas chromatography-mass spectrometry (GC-MS). Quantitative analysis of acetone in plasma was carried out by using external standard method. The SPME conditions (extraction temperature and time) and the method validation were studied. The present method was tested by determination of acetone in diabetes plasma and normal plasma. Acetone concentration in diabetes plasma was found to be higher than 1.8mM, while in normal plasma was lower than 0.017 mM. The results show that the present method is a potential tool for diagnosis of diabetes.

Acetone↗

Metal-ion interactions with sugars. The crystal structure and FTIR study of an SrCl2-fructose complex.

The single-crystal structure of SrCl2 x 2C6H12O6 x 3H2O was determined with Mr = 572.88, a = 16.252, b = 7.941(2), c = 10.751(3) angstroms, beta = 127.652(4) degrees, V = 1098.5(6) angstroms3, C2, Z = 2, mu = 0.71073 angstroms and R = 0.0296 for 1998 observed reflections. The fructose moiety of the complex exists as a beta-d-pyranose. The strontium atom is surrounded by eight oxygen atoms, which are arranged in symmetry-related pairs that are derived from four sugar and two water molecules. Three nonvicinal hydroxyl groups of fructose are involved in strontium binding. All the hydroxyl groups and water molecules are involved in forming an extensive hydrogen-bond network. The Sr-fructose complex is isostructural with the Ca-fructose complex, and the crystal structures and FTIR spectra of the two complexes are compared in this article. The O-H, C-O, and C-O-H vibrations are shifted, and the relative intensities changed in the complexes IR spectra, which indicate sugar metalation. By studying the metal-binding properties of fructose, it is hoped that such would aid in the understanding of the structural chemistry of metal ions interacting with saccharides, as an actual biological system, and thereby aid in the interpretation of some particular biological processes.

Crystallography, X-Ray↗

Comprehensive two-dimensional chromatography and capillary electrophoresis coupled with tandem time-of-flight mass spectrometry for high-speed proteome analysis.

A comprehensive two-dimensional capillary liquid chromatography and capillary zone electrophoresis system coupled with tandem matrix assisted laser desorption/ionization-time of flight-time of flight-mass spectrometry (MALDI-TOF-TOF-MS) proteomics analyzer is presented. Protein/peptide samples were separated by capillary high-performance liquid chromatography (cHPLC). The effluents from cHPLC (the first dimension) were continuously transferred into capillary zone electrophoresis (CZE, the second dimension) through a novel valve-free hydrodynamic sampling interface. The CZE effluents were mixed with alpha-cyano-4-hydroxycinnamic acid (CHCA) matrix sheath flow via CE-MALDI interface, and then directly deposited on the MALDI target at a 3 s time-interval for further MS analysis. The high efficiency of the overall system was demonstrated by analysis of proteins in D20 (human hepatocellular carcinoma model in nude mice with high metastatic potential) liver cancer tissue. More than 300 proteins were identified, which proved the system potential for high-throughput analysis and application in proteomics.

Animals↗

A simple, rapid and sensitive method for determination of aldehydes in human blood by gas chromatography/mass spectrometry and solid-phase microextraction with on-fiber derivatization.

Aldehydes are considered potential markers for enhanced oxidative stress and have been proposed as a diagnostic measure of cancer status. Do to their volatility and activity, it is very difficult to accurately measure aldehydes in human blood. In the present work, gas chromatography/mass spectrometry (GC/MS) and solid-phase microextraction (SPME) with on-fiber derivatization was developed for determination of aldehydes in human blood. O-(2,3,4,5,6-Pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) in aqueous solution was first adsorbed by a SPME fiber, and then the aldehydes in blood samples were headspace extracted by the SPME fiber and rapidly derivatized with PFBHA on the SPME fiber. Finally, the oximes formed were desorbed and detected by GC/MS in electron ionization (EI) mode. Validation of the present method was carried out, and the method was applied to quantitative analysis of the aldehydes in lung cancer blood. The results demonstrated that GC/MS and SPME with on-fiber derivatization is a simple, rapid, sensitive and solvent-free method for the determination of aldehydes in human blood.

Aldehydes↗

Rapid determination of amino acids in neonatal blood samples based on derivatization with isobutyl chloroformate followed by solid-phase microextraction and gas chromatography/mass spectrometry.

The purpose of this study was to develop a simple, rapid and sensitive analytical method for determination of amino acids in neonatal blood samples. The developed method involves the employment of derivatization and a solid-phase microextraction (SPME) technique together with gas chromatography/mass spectrometry (GC/MS). Amino acids in blood samples were derivatized by a mixture of isobutyl chloroformate, methanol and pyridine, and the N(O,S)-alkoxycarbonyl alkyl esters thus formed were headspace extracted by a SPME fiber. Finally, the extracted analytes on the fiber were desorbed and detected by GC/MS in electron impact (EI) mode. L-Valine, L-leucine, L-isoleucine, L-phenylanaline and L-tyrosine in blood samples were quantitatively analyzed by measurement of the corresponding N(O,S)-alkoxycarbonyl alkyl esters using an external standard method. SPME conditions were optimized, and the method was validated. The method was applied to diagnosis of neonatal phenylkenuria (PKU) and maple syrup urine disease (MSUD) by the analyses of five amino acids in blood samples. The results showed that the proposed method is a potentially powerful tool for simultaneous screening for neonatal PKU and MSUD.

Amino Acids↗

[Role of telomerase in silica induced human cell transformation].

OBJECTIVE: To explore the role of telomerase in silica induced human cell transformation in vitro. METHODS: Human telomerase catalytic subunit (hTERT) was transferred into human embryonic lung fibroblasts (HELF). 160 microg/cm2 silica dusts were added to transform HELF and hTERT transduced HELF (HELF-T+) respectively. The telomerase activity and the length of telomere were determined. The growths of the normal and transformed cells were evaluated. RESULTS: The hTERT gene was steadily transferred into HELF. Silica dusts caused the transformations of both HELF-T+ and HELF. The telomerase activities in transformed cells were higher and the telomere length of transformed cells was longer than those of HELF. CONCLUSION: The changes of telomerase activity and telomere length may play an important role in the silica induced human cells transformation.

Cell Line↗

[The clinical analysis of endoscopic repair of cerebrospinal fluid rhinorrhea].

OBJECTIVE: To evaluate the points for attention, repair material and the treatment of complications in repairing cerebrospinal fluid rhinorrhea. METHOD: Fifteen cases of cerebrospinal fluid rhinorrhea were repaired. One case was pituitary tumor involving radiotherapy, two cases were spontaneous, six were traumatic, six were traumatic,six were iatrogenic. RESULT: All cases were successfully repaired by endoscopy. The successful rate were 85.6%. Some cases were relapsed in different positions and some cases needed to be repaired more than two times even five times. CONCLUSION: Endoscopic repair of cerebrospinal fluid rhinorrhea is a very good method with the virtue of convenient, high successful rate, less complication and repeatability. The method is worth spreading.