PubMed Health⌕ Search

Biomedical subjects

Xiangying Du

Publications and source records attributed to Xiangying Du.

7 recordsLinked to original sources

ROC analysis for diagnostic accuracy of fracture by using different monitors.

BACKGROUND: The purpose of this study was to compare diagnostic accuracy by using two types of monitors. METHODS: Four radiologists with 10 years experience twice interpreted the films of 77 fracture cases by using the ViewSonic P75f+ and BARCO MGD221 monitors, with a time interval of 3 weeks. Each time the radiologists used one type of monitor to interpret the images. The image browser used was the Unisight software provided by Atlastiger Company (Shanghai, China), and interpretation result was analyzed via the LABMRMC software. RESULTS: In studies of receiver operating characteristics to score the presence or absence of fracture, the results of images interpreted through monochromic monitors showed significant statistical difference compared to those interpreted using the color monitors. CONCLUSION: A significant difference was observed in the results obtained by using two kinds of monitors. Color monitors cannot serve as substitutes for monochromatic monitors in the process of interpreting computed radiography (CR) images with fractures.

Artificial Intelligence↗

Radiofrequency-enhanced vascular gene transduction and expression for intravascular MR imaging-guided therapy: feasibility study in pigs.

PURPOSE: To evaluate the feasibility of radiofrequency (RF)-enhanced vascular gene transduction and expression by using a magnetic resonance (MR) imaging-heating guidewire as an intravascular heating vehicle during MR imaging-guided therapy. MATERIALS AND METHODS: The institutional committee for animal care and use approved the experimental protocol. The study included in vitro evaluation of the use of RF energy to enhance gene transduction and expression in vascular cells, as well as in vivo validation of the feasibility of intravascular MR imaging-guided RF-enhanced vascular gene transduction and expression in pig arteries. For in vitro experiments, approximately 10(4) vascular smooth muscle cells were seeded in each of four chambers of a cell culture plate. Next, 1 mL of a green fluorescent protein gene (gfp)-bearing lentivirus was added to each chamber. Chamber 4 was heated at approximately 41 degrees C for 15 minutes by using an MR imaging-heating guidewire connected to a custom RF generator. At day 6 after transduction, the four chambers were examined and compared at confocal microscopy to determine the efficiency of gfp transduction and expression. For the in vivo experiments, a lentivirus vector bearing a therapeutic gene, vascular endothelial growth factor 165 (VEGF-165), was transferred by using a gene delivery balloon catheter in 18 femoral-iliac arteries (nine artery pairs) in domestic pigs and Yucatan pigs with atherosclerosis. During gene infusion, one femoral-iliac artery in each pig was heated to approximately 41 degrees C with RF energy transferred via the intravascular MR imaging-heating guidewire, while the contralateral artery was not heated (control condition). At day 6, the 18 arteries were harvested for quantitative Western blot analysis to compare VEGF-165 transduction and expression efficiency between RF-heated and nonheated arterial groups. RESULTS: Confocal microscopy showed gfp expression in chamber 4 that was 293% the level of expression in chamber 1 (49.6% +/- 25.8 vs 16.8% +/- 8.0). Results of Western blot analysis showed VEGF-165 expression for normal arteries in the RF-heated group that was 300% the level of expression in the nonheated group (70.4 arbitrary units [au] +/- 107.1 vs 23.5 au +/- 29.8), and, for atherosclerotic arteries in the RF-heated group, 986% the level in the nonheated group (129.2 au +/- 100.3 vs 13.1 au +/- 4.9). CONCLUSION: Simultaneous monitoring and enhancement of vascular gene delivery and expression is feasible with the MR imaging-heating guidewire.

Animals↗

MR imaging of biodegradable polymeric microparticles: a potential method of monitoring local drug delivery.

Gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) was encapsulated into biodegradable, bioadhesive polymeric microparticles to enable noninvasive monitoring of their local intravesical delivery with MRI. The microparticles were characterized by contrast agent encapsulation and release kinetics, T(1) relaxation rates, and contrast enhancement in vivo. The level of Gd-DTPA loading into microparticles was 14.3 +/- 0.6 mug/mg polymer. The measured T(1) relaxation rates of the microparticles showed a direct dependence on Gd-DPTA content. Both 1.5T and 4.7T MR scanners were used to image murine bladders instilled intravesically with Gd-DTPA-loaded particles in vivo. MR images showed ring-shaped regions of enhancement inscribing the bladder wall, which were attributed to the microparticles that were preferentially adherent to the mucosa lining the urothelium. The images of controls exhibited no such enhancement. The normalized signal intensities measured from post-instillation images were significantly greater (P < 0.05) than those in the pre-instillation images. Contrast enhancement was observed for at least 5 days after the initial instillation, although the enhancement decreased due to microparticle degradation or mucosa renewal. The localized distribution of biodegradable, bioadhesive microparticles encapsulating Gd-DTPA was successfully visualized with MRI in vivo, allowing particle-mediated delivery to be temporally and spatially monitored noninvasively.

Animals↗

SSFP-based MR thermometry.

Of the various techniques employed to quantify temperature changes by MR, proton resonance frequency (PRF) shift-based phase-difference imaging (PDI) is the most accurate and widely used. However, PDI is associated with various artifacts. Motivated by these limitations, we developed a new method to monitor temperature changes by MRI using the balanced steady-state free precession (balanced-SSFP) pulse sequence. Magnitude images obtained with the SSFP pulse sequence were used to find the PRF shift, which is proportional to temperature change. Spatiotemporal temperature maps were successfully reconstructed with this technique in gel phantom experiments and a rabbit model. The results show that the balanced-SSFP-based method is a promising new technique for monitoring temperature.

Animals↗

In vivo US monitoring of catheter-based vascular delivery of gene microspheres in pigs: feasibility.

In this study, the authors tested the feasibility of using ultrasonography (US) to monitor catheter-based vascular gene microsphere delivery. Polymeric biodegradable microspheres (mean diameter, 5 microm) were prepared by using a double-emulsion technique to encapsulate DNA-plasmid-encoding green fluorescent protein (GFP) genes. With use of gene-delivery catheters, GFP microspheres were locally delivered into the left femoral arterial walls of six pigs; the contralateral arteries were not infused with microspheres and thus served as negative control vessels. The delivery procedures were monitored with high-frequency (8-15-MHz) transducer US. The effectiveness of monitoring with US was compared with the effectiveness of monitoring with immunohistochemical anti-GFP staining. A highly echogenic "star burst" sign around the entire vessel wall was seen at US and correlated with immunohistochemical findings that showed the destination of the gene microspheres. Study results demonstrate the potential of US for monitoring catheter-based vascular gene microsphere delivery in vivo.

Animals↗

Development of an intravascular heating source using an MR imaging guidewire.

PURPOSE: To develop a novel endovascular heating source using a magnetic resonance (MR) imaging guidewire (MRIG) to deliver controlled microwave energy into the target vessel for thermal enhancement of vascular gene transfection. MATERIALS AND METHODS: A 0.032-inch MRIG was connected to a 2.45-GHz microwave generator. We 1) calculated the microwave power loss along the MRIG, 2) simulated the power distribution around the MRIG, 3) measured the temperature increase vs. input power with the MRIG, and 4) evaluated the thermal effect on the balloon-compressed/microwave-heated aorta of six living rabbits. In addition, during balloon inflation, we also simultaneously generated high-resolution MR images of the aortic wall. RESULTS: The power loss was calculated to be 3.9 dB along the MRIG. The simulation-predicted power distribution pattern was cylindrically symmetric, analogous to the geometry of vessels. Under balloon compression, the vessel wall could be locally heated at 41 degrees C with no thermal damage apparent on histology. CONCLUSION: This study demonstrates the possibility of using the MRIG as a multifunctional device, not only as a receiver antenna to generate intravascular high-resolution MR images of atherosclerotic plaques and as a conventional guidewire to guide endovascular interventions during MR imaging, but also as a potential intravascular heating source to produce local heat for thermal enhancement of vascular gene transfection.

Animals↗

Detection of dual-gene expression in arteries using an optical imaging method.

We evaluate the in vivo use of an optical imaging method to detect the vascular expression of green fluorescent protein (GFP) or red fluorescent protein (RFP), and to detect the simultaneous expression of GFP and RFP after transduction into arteries by a dual-promoter lentiviral vector driving their concurrent expression. This method involves using a charge-coupled device camera to detect fluorescence, a fiber optic probe to transmit light, and optical filters to distinguish each marker. In animal models, these vectors are locally delivered to target arteries, whereas the gene for a nonfluorescent cell-surface protein is transduced into contralateral arteries as the sham control. The images show distinct areas of bright fluorescence from GFP and RFP along the target arteries on excitation; no exogenous fluorescence is observed in the controls. Measured signal intensities from arteries transduced with the single- and dual-promoter vectors exceed the autofluorescence signal from the controls. Transgene expression of GFP and RFP in vivo is confirmed with confocal microscopy. We demonstrate the use of an optical imaging method to concurrently detect two distinct fluorescent proteins, potentially permitting the expression of multiple transgenes and their localization in the vasculature to be monitored.

Animals↗