PubMed Health⌕ Search

Biomedical subjects

Xiao-Xia Zhu

Publications and source records attributed to Xiao-Xia Zhu.

4 recordsLinked to original sources

Preparation of Au coated polystyrene beads and their application in an immunoassay.

A novel immunoassay method based on polystyrene beads coated with Au nanoparticles (Au@PS) is described. Au nanoparticles were prepared by reductive reaction, and then deposited on the surface of polystyrene beads to form Au coatings. Results indicated that the Au coatings had good stability and that human IgG was immobilized at a concentration of 16 microg/g Au@PS. FITC-labeled rabbit-anti-human IgG and FITC-labeled rabbit-anti-goat IgG were employed to react with the human IgG on Au@PS. Fluorescence imaging results showed that the reaction had good immuno-specificity. In addition, further experiments at the single-bead level indicated that the linear range was 0.05-15 microg/ml, and that the FITC signal could be detected even when the target antibody concentration was as low as 0.01 microg/ml. The assay results were compared with an enzyme-linked immunosorbent assay (ELISA), and showed relatively good reliability.

Animals↗

Preparation of silica encapsulated quantum dot encoded beads for multiplex assay and its properties.

Novel -COOH modified polystyrene beads were prepared by sulfonation grafting, and the surface area and pore volume are greatly improved in comparison with the swelling-treated beads. The optimization coating time is 4 h, and the corresponding -COOH content is approximately 2.1 mmol/g. The scanning electron microscope results show that the silica particles deposited on the beads and formed a silica shell that decreases the leakage of quantum dots (QDs) preferably and improves the bar code stability greatly. The anti-photobleaching of silica-coated beads was studied systemically, and the results show that the half-decay time (t1/2) of the coated beads increases to 537 s--seven times longer than that of the uncoated ones. Further DNA probe hybridization experiments indicated that the coding signal and target signal can be detected simultaneously and that the assays based on these probe-conjugated silica/QD/polystyrene beads have good specificity and sensitivity that can detect a concentration as low as 0.01 microg/ml target DNA in denatured calf thymus DNA solution, indicating that it is feasible to use this kind of bead for multiplex analysis.

DNA↗

Polymeric materials containing bile acids.

Bile acids are biological compounds in the body that have interesting properties and have been used to make special chemical structures in molecular recognition. Various polymers have been synthesized from bile acids. The materials should preserve some of the properties of bile acids, such as biocompatibility, high stability of the steroid nucleus, reactivity of the side groups, optical activity and self-assembling capacity. The synthesis and applications proposed for such polymers are discussed.

Bile Acids and Salts↗

Quantum dot optical encoded polystyrene beads for DNA detection.

A novel multiplex analysis technology based on quantum dot (QD) optical encoded beads was studied. Carboxyl functionalized polystyrene beads, about 100 microm in size, were precisely encoded by the various ratios of two types of QDs whose emission wavelengths are 576 and 628 nm, respectively. Then the different encoded beads were covalently immobilized with different probes in the existing of sulfo-NHS and 1-[3-(Dimethylamino) propyl]-3-ethylcarbodiimide methiodide, and the probe density could reach to 3.1 mmol/g. These probe-linked encoded beads were used to detect the target DNA sequences in complex DNA solution by hybridization. Hybridization was visualized using fluorescein isothiocynate-labeled DNA sequences. The results show that the QDs and target signals can be obviously identified from a single-bead-level spectrum. This technology can detect DNA targets effectively with a detection limit of 0.2 microg/mL in complex solution.

Base Sequence↗