PubMed Health⌕ Search

Biomedical subjects

Xiaohe Xu

Publications and source records attributed to Xiaohe Xu.

6 recordsLinked to original sources

Organophosphorus hydrolase multilayer modified microcantilevers for organophosphorus detection.

We report a biosensor based on organophosphorus hydrolase (OPH) multilayer modified microcantilever (MCL) for detection of organophosphorus compounds (OPs). The assay is based on substrate-dependent bending of the OPH functionalized MCLs. The cantilever bending amplitude at equilibrium was a function of the concentration of paraoxon with the dynamic range extending from 10(-7) to 10(-3)M. The lower detection limit of approximately 10(-7)M for paraoxon was an order of magnitude better than the OPH-based potentiometric and optical biosensors based on pH modulation. There was a good intra-sensor and an acceptable inter-sensor reproducibility as evidenced by the standard errors of 5% and 15%, respectively. OPs measured using this technique included parathion and diisopropyl fluorophosphate (DFP) in the order of paraoxon>DFP>parathion. The conformational change of the OPH was most likely the main origin of MCL bending.

Aryldialkylphosphatase↗

A calixarene based fluorescent Sr2+ and Ca2+ probe.

A fluorescent probe, PyCalix, which has two pyrene moieties at the lower rim of a calix[4]arene fixed in the cone conformation was synthesized and its complexation behavior with alkali and alkaline earth cations was studied by fluorescence spectrometry. The compound showed intramolecular excimer emission at approximately 480 nm in the fluorescence spectra. Upon complexation with alkaline earth metal cations, a decrease of excimer emission was observed. The decrease of excimer emission was accompanied by an increase of monomer emission of pyrenes at 397 nm. The order of complexation constants of PyCalix with metal ions was Sr(+ approximately Ca2+ > Ba2+ > Mg2+ > K+ > Na+ > Cs+ for all reagents. PyCalix doped polyvinyl chloride (PVC) membrane was fabricated and our results showed that this membrane can be used for selective detection of Sr2+.

Journal Article↗

Photon-driven nanomechanical cyclic motion.

Microcantilevers modified by a monolayer of azobenzene molecules bend up and down periodically, switched by a 365 nm UV light, as a result of the conversion of the two configurations of azobenzene molecules in the monolayer.

Journal Article↗

Micromechanical measurement of membrane receptor binding for label-free drug discovery.

A potential novel binding assay based on binding-driven micromechanical motion is described. A membrane preparation containing 5-HT(3AS) receptors was used to modify a microcantilever. The modified microcantilever was found to bend on application of the naturally occurring agonist (5-hydroxytryptamine, which is also called serotonin) or the antagonist MDL-72222, but not to other similar molecules. Control experiments show that cantilevers modified by membrane preparations that do not contain 5-HT(3AS) receptors do not respond to serotonin or MDL-72222. K(d) values obtained for serotonin and MDL-72222 are identical to those obtained from radio-ligand binding assays. These results suggest that the microcantilever system has potential for use in label-free, drug screening applications.

Cell Membrane↗

Detection of femtomolar concentrations of HF Using an SiO(2) microcantilever.

Femtomolar concentrations of hydrogen fluoride, a decomposition component of nerve agents, were detected using a SiO(2) microcantilever. The microcantilever underwent bending due to the reaction of HF with SiO(2). The microcantilever deflection increased as the concentration of HF increased. Other acids, such as HCl, had no effect on the deflection of the cantilever. The mechanism of reaction-induced bending and the correlation of microcantilever deflection with the HF concentration are discussed. The deflection in response to HF of a commercially available silicon cantilever was also studied, and its response was compared with that of the SiO(2) cantilever. Much less bending amplitude and sensitivity were observed for the silicon cantilever.

Biosensing Techniques↗

Detection of Hg2+ using microcantilever sensors.

Trace amounts of Hg2+ are detected by using a microcantilever coated with gold. The microcantilever undergoes bending due to accumulation of Hg2+ on the gold surface. It is found that a concentration of 10(-11) M Hg2+ can be detected using this technology. Other cations, such as K+, Na+, Pb2+, Zn2+, Ni2, Cd2+, Cu2+, and Ca2+ have little or no effect on the deflection of the cantilever. The selectivity of the Hg2+ sensor could be improved by coating the gold surface of microcantilever with a self-assembled monolayer of a long-chain thiol compound.

Adsorption↗