Xiaohui Hao

Publications and source records attributed to Xiaohui Hao.

2 recordsLinked to original sources

Coded excitation for diagnostic ultrasound: a system developer's perspective.

Resolution and penetration are primary criteria for clinical image quality. Conventionally, high bandwidth for resolution was achieved with a short pulse, which results in a tradeoff between resolution and penetration. Coded excitation extends the bounds of this tradeoff by increasing signal-to-noise ratio (SNR) through appropriate coding on transmit and decoding on receive. Although used for about 50 years in radar, coded excitation was successfully introduced into commercial ultrasound scanners only within the last 5 years. This delay is at least partly due to practical implementation issues particular to diagnostic ultrasound, which are the focus of this paper. After reviewing the basics of biphase and chirp coding, we present simulation results to quantify tradeoffs between penetration and resolution under frequency-dependent attenuation, dynamic focusing, and nonlinear propagation. Next we compare chirp and Golay code performance with respect to image quality and system requirements, then we show clinical images that illustrate the current applications of coded excitation in B-mode, harmonic, and flow imaging.

Computer Simulation↗

Characterization of reperfused infarcted myocardium from high-frequency intracardiac ultrasound imaging using homodyned K distribution.

Myocardial changes caused by infarction/reperfusion (contraction band necrosis, hemorrhage, edema, etc.) may result in an increased scatterer density and a variation in scatterer arrangement. This paper, for the first time, models most of the scattering conditions resulting from the interaction of ultrasound and normal/reperfused infarcted myocardium using the homodyned K distribution. Furthermore, this method is used to characterize the change in scatterer density by calculating the effective scatterer number per resolution cell. The reliability and the effects of attenuation and scan conversion on effective scatterer number estimation are discussed. We used in vivo data acquired using high-frequency intracardiac ultrasound imaging (8.5 MHz) from the left and right ventricles of open-chest pigs in an acute infarction/reperfusion model. The results show that the homodyned K distribution describes the statistical distribution of backscattered signal from both normal and abnormal myocardium. A significant increase in scatterer density occurs in the infarcted region after reperfusion compared with the same region at baseline (normal myocardium prior to occlusion). The scatterer density of the normal region does not change significantly after reperfusion. We conclude that the homodyned K distribution may characterize normal and reperfused infarcted myocardium using high-frequency intracardiac ultrasound images.

Animals↗