PubMed Health⌕ Search

Biomedical subjects

Xiaokui Li

Publications and source records attributed to Xiaokui Li.

At least 19 recordsLinked to original sources

Impact of conventional versus biventricular pacing on hemodynamics and tissue Doppler imaging indexes of resynchronization postoperatively in children with congenital heart disease.

OBJECTIVES: We sought to evaluate the effects of biventricular (BDOO) pacing compared with conventional (CDOO) atrioventricular (AV) sequential and atrial (AOO) pacing in children and infants in the early postoperative period after open heart surgery for congenital heart disease (CHD). BACKGROUND: Biventricular pacing using right ventricular (RV) and left ventricular (LV) leads can improve hemodynamics in patients with CHD, but it is unclear whether this occurs in early postoperative children with CHD. METHODS: Nineteen children (age, 5 days to 5.4 years; median, 5.5 months) with a definitive biventricular repair for CHD underwent AOO, CDOO, and BDOO pacing with temporary epicardial leads for 10 min each. The AV delay was 80% of the PR interval for the CDOO and BDOO modes. Lead placement was two right atrial, two RV, and one LV. Blood samples for cardiac index (arterial and venous) and tissue Doppler (TDI) traces were obtained in each pacing mode with a Vivid 7 BT04 digital ultrasound system (GE/VingMed, Horten, Norway) from an apical four-chamber view and analyzed with EchoPac software. RESULTS: The QRS duration was significantly shorter for BDOO compared with CDOO, and the cardiac index was higher with BDOO compared with CDOO. Systemic blood pressure was not different between the three modes of pacing (AOO, CDOO, BDOO). The TDI-derived strain rate showed minimal dyssynchrony in AOO as seen by isovolumic tensing (IVT) and peak systolic contraction (PSC) timing differences between RV and LV. The CDOO worsened dyssynchrony with prolonged DeltaIVT and PSC. The BDOO showed improved synchrony as seen by DeltaIVT and PSC. CONCLUSIONS: The TDI-derived strain rate showed worsened ventricular dyssynchrony with CDOO and improvement with BDOO. Cardiac index and QRS duration were improved by BDOO compared with CDOO. This suggests that short-term pacing with BDOO may benefit children with CHD needing pacing in the postoperative period.

Blood Pressure↗

Impairment of diazoxide-induced formation of reactive oxygen species and loss of cardioprotection in connexin 43 deficient mice.

Protection by ischemic preconditioning is lost in cardiomyocytes and hearts of heterozygous connexin 43 deficient (Cx43+/-) mice. Because connexin 43 (Cx43) is localized in cardiomyocyte mitochondria and mitochondrial Cx43 content is increased with ischemic preconditioning, we now tried to identify a functional defect at the level of the mitochondria in Cx43+/- mice by use of diazoxide and menadione. Diazoxide stimulates the mitochondrial formation of reactive oxygen species (ROS) and menadione generates superoxide at multiple intracellular sites; both substances elicit cardioprotection through increased ROS formation. ROS formation in response to the potassium ionophore valinomycin was also measured for comparison. Menadione (2 micromol/L) and valinomycin (10 nmol/L) induced similar ROS formation in wild-type (WT) and Cx43+/- cardiomyocytes. In contrast, diazoxide (200 micromol/L) increased ROS formation by 43+/-10% versus vehicle in WT, but only by 18+/-4% in Cx43+/- cardiomyoctes (P<0.05). Two hour-simulated ischemia and oxygenated, hypo-osmolar reperfusion reduced viability as compared with normoxia (WT: 7+/-1% versus 39+/-2%, (Cx43+/-): 8+/-1% versus 40+/-3%, P<0.01). Although menadione protected WT and Cx43+/- cardiomyocytes, diazoxide increased viability (17+/-2%, P<0.01) in WT, but not in Cx43+/- (9+/-1%). Menadione (37 microg/kg i.v.) before 30 minutes coronary occlusion and 2 hour reperfusion reduced infarct size in WT and Cx43+/- mice (24+/-4% versus 24+/-5%). In contrast, diazoxide (5 mg/kg i.v.) reduced infarct size in WT (35+/-4% versus 55+/-3% of area at risk, P<0.01), but not in Cx43+/- mice (56+/-2% versus 54+/-3%). Cardiomyocytes of Cx43+/- mice have a specific functional deficit in ROS formation in response to diazoxide and accordingly less protection.

Animals↗

A novel method for the assessment of the accuracy of computing laminar flow stroke volumes using a real-time 3D ultrasound system: In vitro studies.

AIMS: Laminar flow stroke volume (SV) quantification in the ascending aorta or pulmonary artery can provide a measure for determining cardiac output (CO). Comparing flows across different valves can also compute shunt volumes and regurgitant fractions. Quantification methods for 3D color Doppler laminar flow volumes have been developed using reconstructive 3D, but these are cumbersome and time-consuming both in acquisition and measurement. Our study evaluated newly developed color Doppler mapping with real-time live 3D echo to test velocity, spatial and temporal resolution for computing SV. METHODS AND RESULTS: Five rubber tubes (diameters=3.0, 2.25, 2.0, 1.9, 1.7 cm), a freshly dissected porcine aorta (Ao) and a pulmonary artery (PA) (both 2-3 cm diameter) were connected to a pulsatile pump in a water bath. Different SV, from 10 to 80 ml/beat, were studied at pump rates of 40-60 bpm in this phantom model with flow quantified by timed collection. The Nyquist limit was set between 43 and 100 cm/s and frame rate ranged from 14 to 23/s. ECG triggered 3D color Doppler volumes were acquired with a 2-4 MHz probe. The digital scan line data from the 3D volumes, with retained velocity assignments, was exported and analyzed offline by MatLab custom software. Close correlations were found between 3D calculated SV and reference data for all tubes (r=0.98, y=1.14x-1.69, SEE=2.82 ml/beat, p<0.0001). Both Ao and PA flows were also highly correlated with the reference measurements (PA: r=0.98, SEE=3.17 ml/beat; Ao: r=0.99, SEE=3.20 ml/beat). CONCLUSIONS: Real-time 3D color Doppler method could provide an efficient, accurate and reliable method for clinical evaluation and quantification of flow volumes in patients.

Animals↗

The use of live three-dimensional Doppler echocardiography in the measurement of cardiac output: an in vivo animal study.

OBJECTIVES: The purpose of this study was to investigate whether cardiac output (CO) could be accurately computed from live three-dimensional (3-D) Doppler echocardiographic data in an acute open-chested animal preparation. BACKGROUND: The accurate measurement of CO is important in both patient management and research. Current methods use invasive pulmonary artery catheters or two-dimensional (2-D) echocardiography or esophageal aortic Doppler measures, with the inherent risks and inaccuracies of these techniques. METHODS: Seventeen juvenile, open-chested pigs were studied before undergoing a separate cardiopulmonary bypass procedure. Live 3-D Doppler echocardiography images of the left ventricular outflow tract and aortic valve were obtained by epicardial scanning, using a Philips Medical Systems (Andover, Massachusetts) Sonos 7500 Live 3-D Echo system with a 2.5-MHz probe. Simultaneous CO measurements were obtained from an ultrasonic flow probe placed around the aortic root. Subsequent offline processing using custom software computed the CO from the digital 3-D Doppler DICOM data, and this was compared to the gold standard of the aortic flow probe measurements. RESULTS: One hundred forty-three individual CO measurements were taken from 16 pigs, one being excluded because of severe aortic regurgitation. There was good correlation between the 3-D Doppler and flow probe methods of CO measurement (y = 1.1x - 9.82, R(2) = 0.93). CONCLUSIONS: In this acute animal preparation, live 3-D Doppler echocardiographic data allowed for accurate assessment of CO as compared to the ultrasonic flow probe measurement.

Animals↗

A real-time 3-dimensional digital Doppler method for measurement of flow rate and volume through mitral valve in children: a validation study compared with magnetic resonance imaging.

We developed and assessed a real-time 3-dimensional (3D) digital Doppler method for measurement of flow volumes through the mitral valve in children. A total of 13 children (aged 10.46 +/- 2.5 years; 8 boys/5 girls) were enrolled. An ultrasound system (Sonos 7500, Philips, Andover, Mass) was used to acquire raw 3D velocity data for flow measurement based on Gaussian control surface theorem [flow (mL/s) = mean velocity x flow area]. Stroke volume (SV) measured by real-time 3D digital Doppler with the control surface at the mitral valve annulus or orifice was compared with the SV by phase velocity cine magnetic resonance imaging (MRI) at the ascending aorta and by left ventricular volumetric MRI measurement. The best correlation and agreement were seen at the mitral valve orifice by real-time 3D digital Doppler compared with SV by phase velocity cine MRI at the ascending aorta (r = 0.92, mean difference = -5.2 +/- 12.0 mL) and SV by left ventricular volumetric MRI measurement (r = 0.94, mean difference = -0.2 +/- 10.3 mL).

Adolescent↗

Real-time 3-dimensional Doppler echocardiography for the assessment of stroke volume: an in vivo human study compared with standard 2-dimensional echocardiography.

BACKGROUND: Invasive monitors and noninvasive 2-dimensional echocardiography are the standard clinical methods for stroke volume (SV) and cardiac output computation. We studied the use of real-time color Doppler 3-dimensional (3D) echocardiography (3DE) for the assessment of SV in human beings. METHODS: In all, 55 pediatric and adult patients with good transthoracic windows and a normal aortic valve were studied. Real-time 3DE color Doppler volumes incorporating the left ventricular outflow tract and aortic valve were taken. SV was calculated from the color Doppler data in the 3DE DICOM dataset. This was compared with 2-dimensional echocardiography SV calculation from the pulsed wave velocity through the aortic valve along with the left ventricular outflow tract diameter. RESULTS: Five patients were excluded because of mismatching of the 3D color Doppler segments in the 3D volume. The 3D Doppler volumes from the remaining 50 patients were analyzed. There was good correlation between the patients' averaged 3DE SV calculations and the 2-dimensional echocardiography pulsed wave SV estimation (y = 0.84x + 7.8, r2 = 0.90). CONCLUSION: Real-time 3D Doppler echocardiography can be used to accurately calculate SV and cardiac output, compared with conventional pulsed Doppler measurement, in pediatric and adult patients from transthoracic imaging.

Adolescent↗

Accuracy of 3-dimensional color Doppler-derived flow volumes with increasing image depth.

OBJECTIVES: We and others have reported on the use of digital color Doppler sonography from real-time 3-dimensional (3D) echocardiography and its use in accurately calculating cardiac flow volumes, namely stroke volume (SV) and, hence, cardiac output. However, in some patients, image depth is higher than average, and this may affect the accuracy of volume calculation. We sought to investigate the impact of image depth and the accompanying change in signal strength, spatial resolution, and pulse repetition frequency on the accuracy of SV calculation from 3D color Doppler data in an in vitro model. METHODS: A tube model of the left ventricular outflow tract was constructed from plastic tubing and connected to a pulsatile pump. The volume flowing through the tube was imaged using a 3D echocardiography system. Stroke volumes from the pump were computed from the DICOM data using commercially available software and compared with a reference standard of timed volumes with the use of a graduated measuring cylinder over a range of depth settings and SVs. RESULTS: There was good correlation between the 3D-derived SVs and the reference cylinder measures over all depths from 4 to 16 cm at 1-cm increments with a tube diameter of 17 mm, a pump rate of 60 beats/min, and SVs ranging from 20 to 70 mL. The average r(2) value for the 13 different depths was 0.976. However, the accuracy of the 3D method of volume calculation appeared to fall at depths greater than 13 cm, especially at higher SVs. CONCLUSIONS: Stroke volume calculation from real-time 3D color Doppler data in this in vitro study shows that at depths greater than approximately 13 cm, accuracy decreases, especially at higher SVs. This may be due to decreased resolution and the reduced frame rate at these depths. At shallower depths, volume calculation form the 3D Doppler data appears very accurate.

Analysis of Variance↗

Tissue Doppler-derived myocardial acceleration for evaluation of left ventricular diastolic function.

OBJECTIVES: Our purpose was to evaluate a tissue Doppler-based index-peak myocardial acceleration (pACC)-during isovolumic relaxation and in evaluating left ventricular (LV) diastolic function. BACKGROUND: Simple, practical indexes for diastolic function evaluation are lacking, but are much desired for clinical evaluation. METHODS: We examined eight sheep by using tissue Doppler ultrasound images obtained in the apical four-chamber views to evaluate mitral valve annular velocity at the septum and LV wall. The pACC thus derived was analyzed during isovolumic relaxation (IVRT) and during the LV filling period (LVFP). We then changed the hemodynamic status of each animal by blood administration, dobutamine, and metoprolol infusion. We compared the pACC values during IVRT and LVFP over the four different hemodynamic conditions with a peak rate of drop in LV pressure (-dP/dt(min)) and the time constant of LV isovolumic pressure decay (tau), as measured with a high-frequency manometer-tipped catheter. RESULTS: The pACC of the septal side of the mitral valve annulus during IVRT showed a good correlation with -dP/dt(min) (r = -0.80, p < 0.0001) and tau (r = -0.87, p < 0.0001). The mean left atrial pressure (LAP) correlated well with the septal side pACC during LVFP (r = 0.81, p < 0.0001). There was a weak correlation between the mitral valve annulus pACC at the LV lateral wall and mean LAP. CONCLUSIONS: The pACC during IVRT is a sensitive, preload-independent marker for evaluation of LV diastolic function. In addition, pACC during LVFP correlated well with mean LAP.

Animals↗

Fetal ventricular mass determination on three-dimensional echocardiography: studies in normal fetuses and validation experiments.

BACKGROUND: Estimation of ventricular volume and mass is important for baseline and serial evaluation of fetuses with normal or abnormal hearts. Direct measurement of chamber wall volumes and mass can be made without geometric assumptions by 3D fetal echocardiography. Our goals were to determine the feasibility of using fast nongated 3D echocardiography for fetal volumetric and mass assessments, to validate the accuracy of the ultrasound system and the measurement technique, and if satisfactory, to develop normal values for fetal ventricular mass during the second and third trimesters. METHODS AND RESULTS: This was a prospective outpatient study of 90 consecutive normal pregnancies during routine obstetric services at Oregon Health & Science University (Portland). Optimized 3D volumes of the fetal thorax and cardiac chambers were rapidly acquired and later analyzed for right and left ventricular mass by radial summation technique from manual epicardial and endocardial traces. Experiments to validate the ultrasound system and measurement technique were performed with modified small balloon models and in vivo and ex vivo small animal experiments. Our study established the feasibility of fetal ventricular mass measurements with 3D ultrasound technology and developed normal values for right and left ventricular mass from 15 weeks' gestation to term. CONCLUSIONS: Nongated fast 3D fetal echocardiography is an acceptable modality for determination of cardiac chamber wall volume and mass with good accuracy and acceptable interobserver variability. The method should be especially valuable as an objective serial measurement in clinical fetal studies with structurally or functionally abnormal hearts.

Animals↗

Real-time 3-dimensional echocardiography for quantification of the difference in left ventricular versus right ventricular stroke volume in a chronic animal model study: Improved results using C-scans for quantifying aortic regurgitation.

OBJECTIVE: The purpose of our study was to test the applicability of calculating the difference between left ventricular (LV) and right ventricular (RV) stroke volume (SV) for assessing the severity of aortic (Ao) regurgitation (AR) using a real-time 3-dimensional (3D) echocardiographic (RT3DE) imaging system. METHODS: The Ao valve was incised in 5 juvenile sheep, 6 to 10 weeks before the study, to produce AR (mean regurgitant fraction = 0.50). Simultaneous hemodynamic and RT3DE images were obtained on open-chest animals with Ao and pulmonary flows derived by Ao and pulmonary electromagnetic flowmeters balanced against each other. Four stages (baseline, volume loading, sodium nitroprusside, and angiotensin infusion) were used to produce a total of 16 different hemodynamic states. Epicardial scanning was done with a 2.5-MHz probe to sequentially record first the RV and then the LV cavities. Cavity volumes from the 3D echocardiography data were determined from angled sector planes (B-scans) and parallel cutting planes (C-scans, which are planes perpendicular to the direction of the volume interrogation). AR volumes were determined from 3D images by computing and then subtracting RV SVs from LV SVs and then these were compared with electromagnetic flowmeter-derived SV and regurgitant volumes. RESULTS: There was close correlation between RV and LV SVs of the RT3DE and electromagnetic methods (C-scans: LV, r = 0.98, standard error of the estimate [SEE] = 2.62 mL, P =.0001; RV, r = 0.89, SEE = 2.67 mL, P <.0001; and B-scans: LV, r = 0.95, SEE = 3.55 mL, P =.0001; RV, r = 0.77, SEE = 2.78 mL, P =.0003). Because of the small size of the RV in this model, the correlation was closer for C-scans than B-scans for RV SV. AR volume estimation also showed that C-scan (r = 0.93, SEE = 4.23 mL, P <.0001) had closer correlation than B-scan (r = 0.89, SEE = 4.87 mL, P <.0001). However, B-scan-derived AR fraction showed closer correlation than did C-scan (r = 0.82 vs r = 0.85, respectively). CONCLUSION: In this animal model, RT3DE imaging had the ability to reliably quantify both LV (B- and C-scans) and RV SVs and to assess the severity of AR.

Animals↗

Determination of asymmetric cavity volumes using real-time three-dimensional echocardiography: an in vitro balloon model study.

OBJECTIVES: We designed a new in vitro model to test the accuracy and reproducibility of real-time three-dimensional (RT3D) ultrasound imaging for determining a variety of asymmetric cavity volumes with aneurysm. METHODS: Fifteen individual balloon models mimicking ventricular aneurysm were filled with water (170-322.5 ml) without air bubbles and kept in a compressor pump. Compression of the models produced only a change in shape of the balloon and no change in volume. The models were scanned with RT3D echocardiography (RT3DE) and the images recorded on an optical disk. Volumes were measured off line in two phases; maximal compression, where there was maximal change in shape and nil compression, where there was minimal or no change in shape. Volumes were measured by manual tracing technique of the inner border of B-scan images and compared with the drained volume of water from the balloon. RESULTS: There was a high correlation between the drained volume and measured volume at maximal compression (equivalent to end-systole, r = 0.99, y = 0.99x + 3.69, SEE = 6.5 ml), between the drained volume and measured volume at nil compression (equivalent to end-diastole, r = 0.99, y = 0.94x + 12.07, SEE = 5.9 ml), and between volumes measured at maximal and nil compressions (r = 0.99, y = 0.94x + 10.55, SEE = 4.6 ml). CONCLUSION: The results of this experiment show that RT3DE can accurately measure the volumes of a variety of asymmetric ventricular cavities.

Cardiac Volume↗

Validation of volume and mass assessments for human fetal heart imaging by 4-dimensional spatiotemporal image correlation echocardiography: in vitro balloon model experiments.

OBJECTIVE: This study was designed to validate a slow-sweep real-time 4-dimensional (4D) spatiotemporal image correlation method for producing quantitatively accurate dynamic fetal heart images using an in vitro pulsatile balloon model and apparatus. METHODS: To model fetal heart chambers, asymmetric double-walled finger stalls (tips of surgical latex gloves) were used and attached to a laboratory-designed circuit that allowed calibrated changes in the inner balloon volume as well as an intermediate gel mass interposed between the 2 layers. The water-submerged model was attached to a small-volume pulsatile pump to produce phasic changes in volume within the inner balloon at a fixed rate. A sonography system with 4D spatiotemporal image correlation (STIC) capabilities was used for 3-dimensional (3D) and 4D data acquisition. Volume data were analyzed by customized radial summation techniques with 4D data analysis software and compared with known volumes and masses. RESULTS: Fifty-six individual volumes ranging from 2.5 to 10 mL were analyzed. Volume and mass measurements with 4D STIC were highly correlated (R2 > 0.90). The mean percentage error was better (<6%) for volumes exceeding 4 mL and was as low as 0.3% for 6-mL estimations. Measurements in the diastolic phase were the most accurate, followed by mass estimations equivalent to chamber walls. There was a wider range of percentage error in the lowest volumes tested (2.5 mL), which might have arisen from difficulties in spatial resolution or distortions from within the model apparatus itself. Resolution limitations of 4D technology in combination with extremely small volume targets may explain higher error rates at these small volumes. CONCLUSIONS: Four-dimensional STIC is an acceptably accurate method for volume and mass estimations in the ranges comparable with mid- and late-gestation fetal hearts. It is particularly accurate for diastolic estimations, for chamber wall mass measurements, and at volumes of greater than 2.5 mL. This study validates use of 4D STIC technology to overcome the limitations of nongated 3D technology for phasic and quantitative assessments in fetal echocardiography.

Echocardiography, Four-Dimensional↗

Myocardial strain rate is a superior method for evaluation of left ventricular subendocardial function compared with tissue Doppler imaging.

OBJECTIVES: This study was performed to evaluate subendocardial function using strain rate imaging (SRI). BACKGROUND: The subendocardium and mid-wall of the left ventricle (LV) play important roles in ventricular function. Previous methods used for evaluating this function are either invasive or cumbersome. Strain rate imaging by ultrasound is a newly developed echocardiographic modality based on tissue Doppler imaging (TDI) that allows quantitative assessment of regional myocardial wall motion. METHODS: We examined eight sheep using TDI in apical four-chamber views to evaluate the LV free wall. Peak strain rates (SRs) during isovolumic relaxation (IR), isovolumic contraction (IC), and myocardial strain were measured in the endocardial (End), mid-myocardial (Mid), and epicardial (Epi) layers. For four hemodynamic conditions (created after baseline by blood, dobutamine, and metoprolol infusion), we compared differences in SR of End, Mid, and Epi layers to peak positive and negative first derivative of LV pressure (dP/dt). RESULTS: Strain rate during IC showed a good correlation with +dP/dt (r = 0.74, p < 0.001) and during IR with -dP/dt (r = 0.67, p = 0.0003). There was a significant difference in SR between the myocardial layers during both IC and IR (End: -3.4 +/- 2.2 s(-1), Mid: -1.8 +/- 1.5 s(-1), Epi: -0.63 +/- 1.0 s(-1), p < 0.0001 during IC; End: 2.2 +/- 1.5 s(-1), Mid: 1.0 +/- 0.8 s(-1), Epi: 0.47 +/- 0.64 s(-1), p < 0.0001 during IR). Also, SRs of the End and Mid layers during IC were significantly altered by different hemodynamic conditions (End at baseline: 1.7 +/- 0.7 s(-1); blood: 2.0 +/- 1.1 s(-1); dobutamine: 3.4 +/- 2.3 s(-1); metoprolol: 1.0 +/- 0.4 s(-1); p < 0.05). Myocardial strain showed differences in each layer (End: -34.3 +/- 12.6%; Mid: -22.6 +/- 12.1%; Epi: -11.4 +/- 7.9%; p < 0.0001) and changed significantly in different hemodynamic conditions (p < 0.0001). CONCLUSIONS: Strain and SR appear useful and sensitive for evaluating myocardial function, especially for the subendocardial region.

Animals↗

Will a handheld ultrasound scanner be applicable for screening for heart abnormalities in newborns and children?

BACKGROUND: There is significant interest in opportunities to provide echocardiography services for detection of congenital heart disease with portable, or even handheld, devices in remote areas or third world countries where conventional ultrasound systems may not be available. We tested a handheld system (HHS) (SonoHeart, SonoSite Inc, Bothell, Wash) equipped with a broadband, 7- to 4-MHz, miniaturized, curved, linear-array transducer and implemented with an improved directional Doppler flow map. METHODS: All echocardiography scanning was performed in the neonatal nursery, pediatric intensive care department, or pediatric echocardiography laboratory of our institution. We reviewed limited echocardiography view sequences sequentially obtained by the same expert examiner (D.J.S.) in 50 infants and children (age: 1 day to 6 years), with preoperative or postoperative forms of congenital heart disease. Each patient was studied twice, once with a conventional full-feature system (FFS) and then a limited scan with the HHS using similar frequency transducers. The cardiologist (D.J.S.) and blinded research laboratory reviewers (X.L., G.K.M., R.A.R.) read the FFS and HHS image sequences for diagnosis and for grading the quality of the anatomic and flow feature images. The studies were performed and reviewed with the examiner and reviewers blinded to patient diagnosis. RESULTS: The major diagnoses (eg, patent ductus arteriosus, atrio-ventricular (AV) canal, peripheral pulmonary valve stenosis, aortic coarctation, atrial septal defect, ventricular septal defect, preoperative or postoperative tetralogy of Fallot, and mitral regurgitation) were made by both readers, who were unaware of each other's diagnosis results. Furthermore, the average composite HHS cardiac anatomic feature score on a scale of 0 (not visualized) to 3 (visualized precisely) from the parasternal long-axis and 4- or 5-chamber view for cardiac anatomy were 2.67 +/- 0.49 (SD) and 2.50 +/- 0.55, respectively, versus 2.73 +/- 0.45 and 2.55 +/- 0.54 for the FFS. The mean flow feature score, comprising all views, was 2.67 +/- 0.45 (HHS) versus 2.72 +/- 0.48 (FFS). The P values for all above comparisons were >.05. Image quality of the FFS anatomic structures were, thus, not statistically different from the HHS. Although the color cosmetic was different for the HHS directional (nonvelocity) map, only 9% of 150 total findings (including structural abnormalities and flow features, none of which were critical) were missed, whereas the other 91% regurgitant, shunt, stenosis flow features or heart structure were imaged adequately by the HHS in this population. CONCLUSIONS: Implementing high-frequency transducers and programs optimized for tissue and flow imaging on the HHS should provide images of sufficient quality for targeted echocardiography examinations to determine the presence, absence, or status of congenital heart disease in newborns and young children.

Aortic Valve↗

Lower receiving frequencies than transmitting frequencies could yield improved results for contrast imaging: an in vivo study in closed chest canines.

BACKGROUND: Ultrasonic imaging methods of receiving at higher frequencies, which are multiples of the transmitting frequencies (harmonic imaging), are well established as a means of improving myocardial visualization in association with intravenous contrast administration. This exploratory study examined the effect of using receive frequencies that were lower than the transmit frequencies while imaging closed chest dogs with an Ensemble wideband, phase inversion contrast program on a modified Siemens Elegra scanner. METHODS: Intravenous bolus injections of 0.75 mL Definity and 1 mL QW7437 were administered to six anesthetized dogs. Intermittent imaging for contrast visualization was performed using either a broadband array, transmitting at 1.4 MHz and receiving at 2.6-3.2 MHz or a broadband 4-7.5 MHz transducer transmitting at 6.0 MHz and receiving at 4.2-4.5 MHz. Contrast enhancement was measured by videodensitometry, sampling mid-cavity and within the myocardium before and after injection. The changes in videodensity from control to after injection were calculated for each method. RESULTS: There was no significant difference in the change in intracavity videodensity between the two imaging strategies although there was near full intracavity saturation in all cases. However, the change in myocardial density was significantly greater for both contrast agents when using receiving frequencies lower than transmitting frequencies (P = 0.02 and 0.03). The difference in duration of the myocardial blush did not reach statistical significance but it tended to persist for longer with the lower receiving frequencies. CONCLUSION: Delivering sound energy at a slightly higher frequency and receiving at lower than the transmit frequency may be an advantageous method of enhancing myocardial perfusion signals during intravenous contrast echocardiography.

Animals↗

Strain rate acceleration yields a better index for evaluating left ventricular contractile function as compared with tissue velocity acceleration during isovolumic contraction time: an in vivo study.

OBJECTIVE: Our study aimed to investigate whether strain rate acceleration (SRA) during isovolumic contraction time (IVCT) could serve as a sensitive indicator of myocardial function. METHODS: A total of 8 sheep underwent occlusion of left anterior descending coronary artery or diagonal branches and 2 sheep underwent left circumflex coronary artery occlusion to create septal, apical, or basal segment myocardial ischemia 19 to 27 weeks before the study. Baseline, volume-loading, dobutamine, and metoprolol infusion were used to produce 4 hemodynamic stages for each sheep. Doppler tissue imaging was acquired using a 5-MHz probe (GE/VingMed Vivid Five, GE Medical Systems, Milwaukee, Wis) on open-chest animals using the liver as a standoff at the apex. Using software (EchoPac, GE Medical Systems), SRA during IVCT was calculated and compared with tissue velocity acceleration (TVA) during IVCT from areas located in the normal and ischemic zones. Also, invasively monitored left ventricle dP/dt was measured as reference contractile function. RESULTS: Both TVA and SRA during IVCT showed higher values for normal tissue than for ischemic area (P <.0001). SRA for normal wall segments changed significantly during the 4 stages (P =.01) with corresponding changes on high-fidelity left ventricular pressure catheters (r = 0.92). TVA over normal segments showed no significant change (P =.29) in the 4 hemodynamic stages. Both TVA and SRA of the ischemic segments showed no significant change with pharmacologic maneuvers or loading conditions. CONCLUSIONS: SRA and TVA during IVCT are both useful indicators for detecting abnormal heart wall motion. However, SRA tends to be more sensitive than TVA for differentiating the response to stress conditions.

Animals↗