Efficient in vivo 31P magnetization transfer approach for noninvasively determining multiple kinetic parameters and metabolic fluxes of ATP metabolism in the human brain.

ATP metabolism is controlled mainly by ATP synthase (ATP(ase)) and creatine kinase (CK) reactions that regulate cerebral ATP production, transportation, and utilization. These coupled reactions constitute a chemical exchange metabolic network of PCr<-->ATP<-->Pi characterized by two forward and two reverse reaction fluxes, which can be studied noninvasively by in vivo (31)P MRS combined with magnetization transfer (MT). However, it is still debated whether current MT approaches can precisely determine all of these fluxes. We developed and tested a modified in vivo (31)P MT approach based on a multiple single-site saturation (MSS) technique to study the entire PCr<-->ATP<-->Pi network in human occipital lobe at 7T. Our results reveal that 1) the MSS MT approach can explicitly determine all four reaction fluxes with a minimal number of (31)P spectra; 2) the three-spin exchange model accurately determines reverse reaction fluxes, resulting in equal forward and reverse fluxes for both CK and ATP(ase) reactions; and 3) the ATP synthesis rate (8.8 +/- 1.9 micromol/g/min, N = 11) measured in the human brain reflects cerebral oxidative phosphorylation. The MSS MT approach should provide an important modality for noninvasively studying the essential roles of ATP metabolism in brain bioenergetics, function, and diseases.

Adenosine Triphosphate↗

In vivo 31P MRS of human brain at high/ultrahigh fields: a quantitative comparison of NMR detection sensitivity and spectral resolution between 4 T and 7 T.

The primary goal of this study was to establish a rigorous approach for determining and comparing the NMR detection sensitivity of in vivo 31P MRS at different field strengths (B0). This was done by calculating the signal-to-noise ratio (SNR) achieved within a unit sampling time at a given field strength. In vivo 31P spectra of human occipital lobe were acquired at 4 and 7 T under similar experimental conditions. They were used to measure the improvement of the human brain 31P MRS when the field strength increases from 4 to 7 T. The relaxation times and line widths of the phosphocreatine (PCr) resonance peak and the RF coil quality factors (Q) were also measured at these two field strengths. Their relative contributions to SNR at a given field strength were analyzed and discussed. The results show that in vivo 31P sensitivity was significantly improved at 7 T as compared with 4 T. Moreover, the line-width of the PCr resonance peak showed less than a linear increase with increased B0, which leads to a significant improvement in 31P spectral resolution. These findings indicate the advantage of high-field strength to improve in vivo 31P MRS quality in both sensitivity and spectral resolution. This advantage should improve the reliability and applicability of in vivo 31P MRS in studying high-energy phosphate metabolism, phospholipid metabolism and cerebral biogenetics in the human at both normal and diseased states noninvasively. Finally, the approach used in this study for calculating in vivo 31P MRS sensitivity provides a general tool in estimating the relative NMR detection sensitivity for any nuclear spin at a given field strength.

Adult↗

Design of an inductively decoupled microstrip array at 9.4 T.

By independent control of the phases and amplitudes of its elements, the microstrip transmission-line array can mitigate sample-induced RF non-uniformities, and has been widely used as the transceiver in parallel imaging applications. One major challenge in implementing the microstrip array is the reduction of mutual coupling among individual elements. The low-input impedance preamplifier is commonly used for the decoupling purpose. However, it is impractical in the transceiver array design. Although interconnecting capacitors can be utilized to reduce the mutual coupling, they only efficiently work for the neighbor elements. In addition, this approach is impractical at fields higher than 300 MHz, in which the required decoupling capacitance is commonly less than 0.5 pF. We propose a novel decoupling approach by using decoupling inductors in this study. Due to the fact that the decoupling inductance is independent of the resonant frequency, the microstrip arrays can be well decoupled at ultra-high fields. To verify the proposed approach, an eight-channel microstrip array is fabricated and tested at 9.4 T. For this prototype, couplings between elements are significantly reduced by using the interconnecting inductors. The phantom experiment shows that the inductively decoupled microstrip array has good parallel imaging performance.

Equipment Design↗

Manipulation of image intensity distribution at 7.0 T: passive RF shimming and focusing with dielectric materials.

PURPOSE: To investigate the effects of high dielectric material padding on RF field distribution in the human head at 7.0 T, and demonstrate the feasibility and effectiveness of RF passive shimming and focusing with such an approach. MATERIALS AND METHODS: The intensity distribution changes of gradient-recalled-echo (GRE) and spin-echo (SE) images of a human head acquired with water pads (dielectric constant = 78) placed in specified configurations around the head at 7.0 T were evaluated and compared with computer simulation results using the finite difference time domain (FDTD) method. The contributions to the B(1) field distribution change from the displacement current and conductive current of a given configuration of dielectric padding were determined with computer simulations. RESULTS: MR image intensity distribution in the human head with an RF coil at 7.0 T can be changed drastically by placing water pads around the head. Computer simulations reveal that the high permittivity of water pads results in a strong displacement current that enhances image intensity in the nearby region and alters the intensity distribution of the entire brain. CONCLUSION: The image intensity distribution in the human head at ultra-high field strengths can be effectively manipulated with high permittivity padding. Utilizing this effect, the B(1) field inside the human head of a given RF coil can be adjusted to reduce the B(1) field inhomogeneity artifact associated with the wave behavior (RF passive shimming) or to locally enhance the signal-to-noise ratio (SNR) in targeted regions of interest (ROIs; RF field focusing).

Brain↗

Open-chest 31P magnetic resonance spectroscopy of mouse heart at 4.7 Tesla.

PURPOSE: To develop a rapid, robust, and accurate method for assessing myocardial energetics in mice and demonstrate its applicability to mouse models of acquired and genetic heart disease. MATERIALS AND METHODS: We combined surface coil localization (10-mm diameter, tunable between (1)H and (31)P, using adiabatic half-passage radiofrequency pulses) and surgery (electrocautery removal of anterior chest wall) to create an open-chest method for acquiring in vivo (31)P nuclear magnetic resonance (NMR) cardiac spectra from mice at 4.7T within 12 minutes. Normal BALB/c mice, BALB/c with myocardial infarction (MI), cardiomyocyte-restricted peroxisome proliferator-activated receptor-delta knockout (KO) (CR-PPARd(-/-)) and control loxP-flanked Ppard (Ppard(flox/flox)) mice were examined. RESULTS: The mean phosphocreatine (PCr)/adenosine triphosphate (ATP) ratios in control BALB/c mice, BALB/c MI mice, Ppard(flox/flox) mice, and PPAR-delta KO mice were 2.13 +/- 0.09 (N = 11), 1.35 +/- 0.07 (N = 9, P < 0.001 vs. BALB/c control), 1.92 +/- 0.09 (N = 5), and 1.31 +/- 0.12 (N = 5, P < 0.005 vs. Ppard(flox/flox) control), respectively. The significant depression of myocardial PCr/ATP we observed in these genetic/acquired models of heart disease was in accord with previous data from analogous large animal models. No NMR signal contamination from chamber blood or adjacent skeletal muscle was identified. CONCLUSION: This new technique provides cardiac (31)P spectra suitable for accurate quantitative analysis in a relatively short acquisition time, is suitable for terminal studies of mouse myocardial energy metabolism, and could be installed in virtually any NMR laboratory to study myocardial energetics in numerous mouse models of human heart disease.

Adenosine Triphosphate↗

Transmit and receive transmission line arrays for 7 Tesla parallel imaging.

Transceive array coils, capable of RF transmission and independent signal reception, were developed for parallel, 1H imaging applications in the human head at 7 T (300 MHz). The coils combine the advantages of high-frequency properties of transmission lines with classic MR coil design. Because of the short wavelength at the 1H frequency at 300 MHz, these coils were straightforward to build and decouple. The sensitivity profiles of individual coils were highly asymmetric, as expected at this high frequency; however, the summed images from all coils were relatively uniform over the whole brain. Data were obtained with four- and eight-channel transceive arrays built using a loop configuration and compared to arrays built from straight stripline transmission lines. With both the four- and the eight-channel arrays, parallel imaging with sensitivity encoding with high reduction numbers was feasible at 7 T in the human head. A one-dimensional reduction factor of 4 was robustly achieved with an average g value of 1.25 with the eight-channel transmit/receive coils.

Brain↗

Higher-order harmonic transmission-line RF coil design for MR applications.

A novel concept based on the use of higher-order harmonic resonances in a transmission-line resonator is introduced for the design of high-frequency RF coils at high and ultrahigh fields, where conventional RF coil designs present difficulties and limitations. To demonstrate this concept, we successfully designed and fabricated a 400-MHz RF coil for rat imaging using a second-harmonic resonant microstrip transmission line. This coil has a high Q-factor, reduces coil-cable interactions without the use of a matching balun, and has a broad range for tuning the coil's resonant frequency at the loaded condition. This work demonstrates that the use of higher-order harmonics in a transmission-line resonator provides an alternative, efficient approach to the design of large and high-frequency RF coils.

Animals↗

In vivo 17O NMR approaches for brain study at high field.

17O is the only stable oxygen isotope that can be detected by NMR. The quadrupolar moment of 17O spin (I = 5/2) can interact with local electric field gradients, resulting in extremely short T1 and T2 relaxation times which are in the range of several milliseconds. One unique NMR property of 17O spin is the independence of 17O relaxation times on the magnetic field strength, and this makes it possible to achieve a large sensitivity gain for in vivo 17O NMR applications at high fields. In vivo 17O NMR has two major applications for studying brain function and cerebral bioenergetics. The first application is to measure the cerebral blood flow (CBF) through monitoring the washout of inert H2 17O tracer in the brain tissue following an intravascular bolus injection of the 17O-labeled water. The second application, perhaps the most important one, is to determine the cerebral metabolic rate of oxygen utilization (CMRO2) through monitoring the dynamic changes of metabolically generated H2 17O from inhaled 17O-labeled oxygen gas in the brain tissue. One great merit of in vivo 17O NMR for the determination of CMRO2 is that only the metabolic H2 17O is detectable. This merit dramatically simplifies both CMRO2 measurement and quantification compared to other established methods. There are two major NMR approaches for monitoring H2 17O in vivo, namely direct approach by using 17O NMR detection (referred as direct in vivo 17O NMR approach) and indirect approach by using 1H NMR detection for measuring the changes in T2- or T1rho-weighted proton NMR signals caused by the 17O-1H scalar coupling and proton chemical exchange (referred as indirect in vivo 17O NMR approach). Both approaches are suitable for CBF measurements. However, recent studies indicated that the direct in vivo 17O NMR approach at high/ultrahigh fields appears to offer significant advantages for quantifying and imaging CMRO2. New developments have further demonstrated the feasibility for establishing a completely noninvasive in vivo 17O NMR approach for imaging CMRO2 in a rat brain during a brief 17O2 inhalation. This approach should be promising for studying the central role of oxidative metabolism in brain function and neurological diseases. Finally, the similar approach could potentially be applied to image CMRO2 noninvasively in human brain.

Animals↗

An inverted-microstrip resonator for human head proton MR imaging at 7 tesla.

As an extension of the previously developed microstrip transmission line (MTL) RF coil design, a high-frequency RF volume coil using multiple inverted MTL (iMTL) resonators for human head imaging at high magnetic field strength of 7 tesla (T) is reported. Compared to conventional MTL resonators, iMTL resonators can operate at higher frequency with lower losses and, thus, are suitable for designs of high-frequency RF volume coils with large coil size for human MR imaging and spectroscopy at high fields. An approach using capacitive terminations was analyzed and applied to the design of the iMTL volume coil for improving RF field homogeneity and broadening frequency-tuning range. A performance-comparison study was conducted between the prototype iMTL volume coil and a custom-built TEM volume coil at 7 T. The iMTL volume coil presents a comparable SNR and intrinsic B1 homogeneity to the TEM volume coil. Phantom and the human head images acquired using the iMTL volume coil are also presented. The proposed iMTL volume coil provides an efficient and alternative solution to design high-frequency and large-size volume coils for human MR applications at very high fields.

Brain↗

Phantom design method for high-field MRI human systems.

A phantom design method suitable for high-field MRI based on the RF field wave characteristics of sample and experimental validations at 7.0 T and 3.0 T are presented. The RF field distribution in a phantom with a given RF coil system is primarily determined by the sample size relative to the wavelength inside the sample, and the ratio between the displacement and conduction currents. Experimental results demonstrate that the MR image intensity patterns associated with wave behavior in human samples at a given field strength can be reproduced with a phantom at the same or different field strengths once the dimension and penetration constant are scaled by the corresponding wavelength in the sample medium.

Brain Mapping↗

Measurement of arterial input function of 17O water tracer in rat carotid artery by using a region-defined (REDE) implanted vascular RF coil.

A method of determining arterial input function (AIF) by continuously detecting the (17)O MR signal changes of (17)O-labeled water tracer in the rat carotid artery using a region-defined (REDE) implanted vascular RF coil at 9.4 Tesla is reported. This coil has a compact physical size of 1 mm inner diameter, 3 mm outer diameter and 11 mm in length. It can be readily implanted into the rat neck and wrapped around the rat carotid artery for achieving adequate MR detection sensitivity for determining AIF with minimal surgical trauma. Water phantom and in vivo MR experiments were conducted for validating the coil's performance. A signal-to-noise ratio of approximately 20:1 was achieved for the (17)O signal acquired from naturally abundant H(2)(17)O in a small amount of blood (approximately 7 microl) inside the rat carotid artery with an acquisition time of 11 s. The REDE RF coil design electromagnetically isolates the rat carotid artery from surrounding tissues and ensures that the MR signal detected by the RF coil is only attributable to the artery blood. It also minimizes the electromagnetic coupling between the implanted RF coil and a head surface coil tuned at the same operating frequency (two-coil configuration). This configuration allowed simultaneous measurements of dynamic changes of (17)O MR signal of the H(2)(17)O tracer in both rat carotid artery and brain. Compared to most contemporary MR approaches, the REDE implanted RF provides a simple, accurate, and promising solution for determination of AIF in small experimental animals.

Animals↗

A microstrip transmission line volume coil for human head MR imaging at 4T.

A high-frequency RF volume coil based on the use of microstrip transmission line (MTL) has been developed for in vivo 1H MR applications on the human head at 4T. This coil is characterized by major advantages: (i) completely distributed coil circuit, (ii) high-quality factor (Q), (iii) simple coil structure, and (iv) better sensitivity and less signal-intensity variation in the MR image of the human head compared with an RF shielded birdcage coil of similar coil size. The proposed MTL volume coil does not require additional RF shielding for preventing Q degradation from radiation losses due to the unique MTL structure; thus, it provides a maximal useable space inside the volume coil when compared with most volume coils available at high fields with the same overall coil size. The intrinsic B(1) distribution of the MTL volume coil effectively compensates for the dielectric resonance effect at 4T and improves the signal homogeneity in human head MR images in the transaxial planes. The results of this study demonstrate that the MTL volume coil design provides an efficient and simple solution to RF volume coil design for human MR studies at high fields.

Artifacts↗

Unusual radiation response of gemcitabine-treated HeLa cells: reduced and enhanced survival.

Gemcitabine, a widely reported radiosensitizer, was found to increase and decrease radiation survival of HeLa cells under different treatment conditions. A 24 h exposure at 10 or 20 nM increased S phase cells and radiation survival, with a dose modification factor (DMF) of 0.82 or 0.78, respectively. Shortening exposure time avoided cell cycle effect and eliminated increases of radiation survival. Treatment for 1 h showed no change in radioresponse (DMF of 1.03) at 20 nM versus radiosensitization at 1, 2, or 20 microM (DMF of 1.66). These results document an enhanced radiation survival while confirming reported radiosensitization under different conditions. Such findings may impact drug dosimetry.

Cell Survival↗

Development of (17)O NMR approach for fast imaging of cerebral metabolic rate of oxygen in rat brain at high field.

A comprehensive technique was developed for using three-dimensional (17)O magnetic resonance spectroscopic imaging at 9.4T for rapidly imaging the cerebral metabolic rate of oxygen consumption (CMRO(2)) in the rat brain during a two-min inhalation of (17)O(2). The CMRO(2) value (2.19 +/- 0.14 micromol/g/min, n = 7) was determined in the rat anesthetized with alpha-chloralose by independent and concurrent (17)O NMR measurements of cerebral H(2)17O content, arterial input function, and cerebral perfusion. CMRO(2) values obtained were consistent with the literature results for similar conditions. Our results reveal that, because of its superior sensitivity at ultra-high fields, the (17)O magnetic resonance spectroscopic imaging approach is capable of detecting small dynamic changes of metabolic H(2)17O during a short inhalation of (17)O(2) gas, and ultimately, for imaging CMRO(2) in the small rat brain. This study provides a crucial step toward the goal of developing a robust and noninvasive (17)O NMR approach for imaging CMRO(2) in animal and human brains that can be used for studying the central role of oxidative metabolism in brain function under normal and diseased conditions, as well as for understanding the mechanisms underlying functional MRI.

Animals↗

Analysis of wave behavior in lossy dielectric samples at high field.

Radiofrequency (RF) field wave behavior and associated nonuniform image intensity at high magnetic field strengths are examined experimentally and numerically. The RF field produced by a 10-cm-diameter surface coil at 300 MHz is evaluated in a 16-cm-diameter spherical phantom with variable salinity, and in the human head. Temporal progression of the RF field indicates that the standing wave and associated dielectric resonance occurring in a pure water phantom near 300 MHz is greatly dampened in the human head due to the strong decay of the electromagnetic wave. The characteristic image intensity distribution in the human head is the result of spatial phase distribution and amplitude modulation by the interference of the RF traveling waves determined by a given sample-coil configuration. The numerical calculation method is validated with experimental results. The general behavior of the RF field with respect to the average brain electrical properties in a frequency range of 42-350 MHz is also analyzed.

Electromagnetic Phenomena↗

Polarization of the RF field in a human head at high field: a study with a quadrature surface coil at 7.0 T.

The RF field intensity distribution in the human brain becomes inhomogeneous due to wave behavior at high field. This is further complicated by the spatial distribution of RF field polarization that must be considered to predict image intensity distribution. An additional layer of complexity is involved when a quadrature coil is used for transmission and reception. To study such complicated RF field behavior, a computer modeling method was employed to investigate the RF field of a quadrature surface coil at 300 MHz. Theoretical and experimental results for a phantom and the human head at 7.0 T are presented. The results are theoretically important and practically useful for high-field quadrature coil design and application.

Brain↗