PubMed Health⌕ Search

Biomedical subjects

Xiaoping Ao

Publications and source records attributed to Xiaoping Ao.

6 recordsLinked to original sources

Microdialysis sampling of cytokines.

Microdialysis sampling is a well-known method for collection of low molecular weight hydrophilic analytes. Due to the success of this sampling technique for these analytes, many researchers have wanted to extend the use of this method to a wider range of analytes-particularly proteins and peptides. These analytes pose unique challenges during microdialysis sampling. The primary challenges are the reduced recovery across the dialysis semi-permeable membrane and the volume limitations/requirements for the typical immunoassay methods used for detection of proteins. This review covers the practical and theoretical aspects needed for in vivo microdialysis sampling of cytokines, which are a vitally important class of signaling proteins. In addition to the basics of the microdialysis method for sampling cytokines, the use of the microdialysis device as a localized cytokine delivery method is also described. Since relative recovery of cytokines is often low during microdialysis sampling, methods to improve the membrane recovery are discussed for in vitro and in vivo applications.

Animals↗

No delayed temporal response to sample concentration changes during enhanced microdialysis sampling using cyclodextrins and antibody-immobilized microspheres.

The temporal response to concentration changes external to a microdialysis probe containing trapping agents in the perfusion fluid was studied. Native beta-cyclodextrin and a water-soluble beta-cyclodextrin polymer were used as trapping agents in the microdialysis perfusion fluid to study the temporal concentration response to carbamazepine, a hydrophobic analyte. The temporal response of microdialysis probes containing antibody-immobilized microspheres against five different cytokines (tumor necrosis factor-alpha (TNF-alpha), interferon-gamma (IFN-gamma), interleukin-2 (IL-2), IL-4, and IL-5) to concentration changes outside of the probe was also determined. In both cases, no delayed temporal response of enhanced microdialysis was observed for either carbamazepine or the cytokines as compared to standard microdialysis sampling procedures.

Animals↗

Multiplexed cytokine detection in microliter microdialysis samples obtained from activated cultured macrophages.

Microdialysis sampling probes were used to collect cytokine samples from lipopolysaccharide (LPS)-stimulated macrophages. The probes were immersed into cell culture wells containing either RAW 264.7 or isolated peritoneal macrophages. Dialysates (15 microL) from these wells were subjected to a multiplexed cytokine sandwich immunoassay platform analyzed by flow cytometry that measures up to six separate cytokines, interleukin-6 (IL-6), interleukin-10 (IL-10), interleukin-12p70 (IL-12p70), interferon-gamma (IFN-gamma), macrophage chemoattractant protein-1 (MCP-1), and tumor necrosis factor-alpha (TNF-alpha) in a single 15-muL sample. In vitro microdialysis sampling relative recovery experiments showed that only IFN-gamma, IL-6, MCP-1, and TNF-alpha could be recovered across a commercially-available 100-kDa MWCO microdialysis membrane. Eleven hours after LPS addition (1 microg/mL), RAW 264.7 macrophages secreted greater than 8000 pg/mL of TNF-alpha and greater than 1000 pg/mL MCP-1. With the peritoneal macrophages, greater than 6000 pg/mL of IL-6, MCP-1, and TNF-alpha were obtained. The maximum dialysate concentrations obtained from the RAW macrophages were 1300 pg/mL for TNF-alpha and 55 pg/mL for MCP-1. Maximum cytokine concentrations from peritoneal macrophage dialysates reached approximately 2000 pg/mL, 1100 pg/mL and 500 pg/mL for TNF-alpha, MCP-1 and IL-6, respectively. Microdialysis sampling allowed for 20-min samples to be collected during the cytokine release from the activated macrophages. These results demonstrate that microdialysis sampling can be used for collection of selected cytokines with improved temporal resolution.

Animals↗

In vivo microdialysis sampling of cytokines produced in mice given bacterial lipopolysaccharide.

Cytokines are proteins that mediate communication between cells of the immune system as well as certain other non-immune host cells. These proteins are produced by many cell types and they mediate immune and inflammatory responses. However, the direct site analysis of these critical proteins is hampered by the lack of site-specific tools available for such direct measurements. In this study, both in vitro and in vivo microdialysis sampling of different cytokines (tumor necrosis factor-alpha [TNF-alpha], interferon-gamma [IFN-gamma], interleukin-6 [IL-6], IL-12p70, and macrophage chemoattractant protein-1 [MCP-1]) was performed. A mouse model of bacterial lipopolysaccharide (LPS) administration and response pattern was used for in vivo studies. Three cytokines, TNF-alpha, IL-6, and MCP-1 were quantified in the serum from mice given LPS. In vivo studies demonstrated the ability to monitor increasing levels of these cytokines (TNF-alpha, IL-6, and MCP-1) via microdialysis probes placed in the peritoneal cavity of mice given LPS. All three cytokines were quantified simultaneously in 15 muL of dialysate using a multiplexed bead-based immunoassay for flow cytometry. The detected dialysate cytokine concentrations varied between 200 pg/mL and 1500 pg/mL for TNF-alpha, between 600 pg/mL and 3000 pg/mL for MCP-1, and between 2700 pg/mL and more than 5000 pg/mL for IL-6. The detected serum cytokine concentrations ranged from 5700 pg/mL to 35,000 pg/mL for TNF-alpha, from 40,000 pg/mL to 65,000 pg/mL for MCP-1, and greater than than 100,000 pg/mL for IL-6. This work demonstrates that microdialysis sampling can be used in vivo to collect temporal profiles of cytokine production.

Animals↗

Enhanced microdialysis relative recovery of inflammatory cytokines using antibody-coated microspheres analyzed by flow cytometry.

Achieving high relative recovery (RR) of proteins during microdialysis sampling is difficult due to the diffusion limitations inherent to this sampling process. This often causes low microdialysis RR for proteins with molecular weight >10 kDa. A RR enhancement process for microdialysis sampling of proteins has been developed that can be readily used with flow cytometers. Multiplexed RR enhancement and detection of five different cytokines (TNF-alpha, IFN-gamma, IL-2, IL-4, and IL-5) was achieved by including antibody-coated microspheres in the microdialysis perfusion fluid. Inclusion of these antibody-coated microspheres causes an increase in the analyte diffusive driving force across the dialysis membrane and a subsequent increase in the relative recovery. For the five cytokines, typical control and enhanced relative recoveries at a 1.0 microL/min flow rate were as follows (n = 3): TNF-alpha, 5.5 +/- 0.6% and 60.4 +/- 5.8%; IFN-gamma, 2.6 +/- 0.3% and 25.8 +/- 2.3%; IL-5, 1.4 +/- 0.2% and 4.9 +/- 0.1%; IL-4, 10.9 +/- 0.6% and 78.8 +/- 8.0%; and IL-2, 4.1 +/- 0.4% and 19.8 +/- 2.5%. Using this approach, a four- to 12-fold enhancement of microdialysis RR was achieved for the five cytokines from a quiescent solution. The enhancement varies among the five cytokines and may be due to different diffusive and antibody binding properties. TNF-alpha exhibited the highest RR enhancement, while IL-5 exhibited the lowest. Experimental parameters that affect the enhancement, such as flow rate, sample collection volume, and bead density, were studied.

Antibodies↗

Water-soluble cyclodextrin polymers for enhanced relative recovery of hydrophobic analytes during microdialysis sampling.

Microdialysis relative recovery (RR) enhancement using different water-soluble, epichlorohydrin-based cyclodextrin polymers (CD-EPS) was studied in vitro for different analytes, amitryptiline, carbamazepine, hydroquinone, ibuprofen, and 4-nitrophenol. When compared to the native CDs (alpha, beta, and gamma) on a per mole basis, the CD-EPS enhanced microdialysis RR was either statistically greater or the same. beta-CD-EPS was more highly retained than native beta-CD by a 20 000 Da molecular weight cutoff (MWCO) polycarbonate membrane, but showed no statistical difference for loss across a 100 000 Da MWCO polyethersulfone membrane (PES). When the same weight percent of beta-CD or beta-CD-EPS was included in the microdialysis perfusion fluid, the beta-CD-EPS produced a higher microdialysis RR than native beta-CD for all analytes across the PES membrane. However, enhancements for the PC membrane were statistically insignificant when beta-CD and beta-CD-EPS were compared on a per mole basis. These results suggest that CD-EPS may be used as effective enhancement agents during microdialysis sampling and for some membranes provide the additional advantage of being retained more than native CDs.

Cellulose↗