PubMed Health⌕ Search

Biomedical subjects

Xiaorong Liang

Publications and source records attributed to Xiaorong Liang.

9 recordsLinked to original sources

A pulsed triple ionization source for sequential ion/ion reactions in an electrodynamic ion trap.

A pulsed triple ionization source, using a common atmosphere/vacuum interface and ion path, has been developed to generate different types of ions for sequential ion/ion reaction experiments in a linear ion trap-based tandem mass spectrometer. The triple ionization source typically consists of a nano-electrospray emitter for analyte formation and two other emitters, an electrospray emitter and an atmospheric pressure chemical ionization emitter or a second nano-electrospray emitter for formation of the two different reagent ions. The three emitters are positioned in a parallel fashion close to the sampling orifice of the tandem mass spectrometer. The potentials applied to each emitter are sequentially pulsed so that desired ions are generated separately in time and space. Sequential ion/ion reactions take place after analyte ions of interest and different set of reagent ions are sequentially injected into a linear ion trap, where axial trapping is effected by applying an auxiliary radio frequency voltage to the end lenses. The pulsed triple ionization source allows independent optimization of each emitter and can be readily coupled to any atmospheric pressure ionization interface with no need for instrument modifications, provided the potentials required to transmit the ion polarity of interest can be synchronized with the emitter potentials. Several sequential ion/ion reactions examples are demonstrated to illustrate the analytical usefulness of the triple ionization source in the study of gas-phase ion/ion chemistry.

Animals↗

Implementation of ion/ion reactions in a quadrupole/time-of-flight tandem mass spectrometer.

A commercial quadrupole/time-of-flight (QqTOF) tandem mass spectrometer has been adapted for ion/ion reaction studies. To enable mutual storage of oppositely charged ions in a linear ion trap, the oscillating quadrupole field of the second quadrupole of the system (Q2) serves to store ions in the radial dimension while auxiliary radio frequency is superposed on the end lenses of Q2 during the reaction period to create barriers in the axial dimension. A pulsed dual electrospray (ESI) source is directly coupled to the instrument interface for the purpose of proton transfer reactions. Singly and doubly charged protein ions as high in mass as 66 kDa are readily formed and observed after proton-transfer reactions. For the modified instrument, the mass resolving power is approximately 8000 for a wide m/z range, and the mass accuracy is approximately 20 ppm for external calibration and approximately 5 ppm for internal calibration after ion/ion reactions. Parallel ion parking is demonstrated with a six-component protein mixture, which shows the potential application of reducing spectral complexity and concentrating certain charge states. The current system has high flexibility with respect to defining MS(n) experiments involving collision-induced dissociation (CID) and ion/ion reactions. Protein precursor and CID product masses can be determined with good accuracy, providing an attractive platform for top-down proteomics. Electron transfer dissociation ion/ion reactions are implemented by using a pulsed nano-ESI/atmospheric pressure chemical ionization dual source for ionization. The reaction between protonated peptide ions and radical anions of 1,3-dinitrobenzene formed exclusively c- and z-type fragment ions.

Algorithms↗

Alternately pulsed nanoelectrospray ionization/atmospheric pressure chemical ionization for ion/ion reactions in an electrodynamic ion trap.

The alternate operation of nanoelectrospray ionization and atmospheric pressure chemical ionization, using a common atmosphere/vacuum interface and ion path, has been implemented to facilitate ion/ion reaction experiments in a linear ion trap-based tandem mass spectrometer. The ion sources are operated in opposite polarity modes whereby one of the ion sources is used to form analyte ions while the other is used to form reagent ions of opposite polarity. This combination of ion sources is well-suited to implementation of experiments involving multiply charged ions in reaction with singly charged ions of opposite polarity. Three analytically useful ion/ion reaction types are illustrated: the partial deprotonation of a multiply protonated protein, the partial protonation of a multiply deprotonated oligonucleotide, and electron transfer to a multiply protonated peptide. The approach described herein is attractive in that it enables both single proton-transfer and single electron-transfer ion/ion reaction experiments to be implemented without requiring major modifications to the tandem mass spectrometer hardware. Furthermore, a wide range of reactant ions can be formed with these ionization methods and the pulsed nature of operation appears to lead to no significant compromise in the performance of either ion source.

Atmospheric Pressure↗

Ion trap versus low-energy beam-type collision-induced dissociation of protonated ubiquitin ions.

The beam-type and ion trap collision-induced dissociation (CID) behaviors of protonated bovine ubiquitin ions were studied for charge states ranging from +6 to +12 on a modified triple quadrupole/linear ion trap tandem mass spectrometer. Both beam-type CID and ion trap CID were conducted in a high-pressure linear ion trap, followed by proton-transfer ion/ion reactions to reduce the charge states of product ions mostly to +1. The product ions observed under each activation condition were predominantly b- and y-type ions. Fragmentation patterns showed a much stronger dependence on parent ion charge state with ion trap CID than with beam-type CID using nitrogen as the collision gas, with preferential cleavages C-terminal to aspartic acid at relatively low charge states, nonspecific fragmentation at moderate charge states, and favored cleavages N-terminal to proline residues at high charge states. In the beam-type CID case, extensive cleavage along the protein backbone was noted, which yielded richer sequence information (77% of backbone amide bond cleavages) than did ion trap CID (52% of backbone amide bond cleavages). Collision gas identity and collision energy were also evaluated in terms of their effects on the beam-type CID spectrum. The use of helium as collision gas, as opposed to nitrogen, resulted in CID behavior that was sensitive to changes in collision energy. At low collision energies, the beam-type CID data resembled the ion trap CID data with preferential cleavages predominant, while at high collision energies, nonspecific fragmentation was observed with increased contributions from sequential fragmentation.

Animals↗

[A new approach to wavelet-based P-wave detection].

According to the characteristics of four basic P morphologies, combining the wavelet transform and the amplitude and slope of transformed P wave, a new P-wave detecting method based on "wavelet-amplitude-slope" algorithm is presented: First search out all modulus maximum pairs to satisfy the threshold after wavelet transform, and then applying the amplitude and slope criterion exclude the interferes and detect the P peak and its shape, last determine the onset and end of P wave respectively which should be separately calculated for single-peak and double-peak P wave (or biphasic P wave). The approach is applied in experiments of data from MIT/BIH database and randomly collected data of clinical ECG. The experimental statistical results shows that the correct detecting rate is as high as 96% compared to manual annotation.

Algorithms↗

Pulsed dual electrospray ionization for ion/ion reactions.

A pulsed dual electrospray ionization source has been developed to generate positive and negative ions for subsequent ion/ion reaction experiments. The two sprayers, typically a nano-electrospray emitter for analytes and an electrospray emitter for reagents, are positioned in a parallel fashion close to the sampling orifice of a triple quadrupole/linear ion trap tandem mass spectrometer (Sciex Q TRAP). The potentials applied to each sprayer are alternately pulsed so that ions of opposite polarity are generated separately in time. Ion/ion reactions take place after ions of each polarity are sequentially injected into a high-pressure linear ion trap, where axial trapping is effected by applying an auxiliary radio frequency voltage to the end lenses. The pulsed dual electrospray source allows optimization of each sprayer and can be readily coupled to any spray interface with no need for instrument modifications, provided the potentials required to transmit the ion polarity of interest can be alternated in synchrony with the emitter potentials. Ion/ion reaction examples such as charge reduction of multiply charged protein ions, charge inversion of peptides ions, and protein-protein complex formation are given to illustrate capabilities of the pulsed dual electrospray source in the study of gas-phase ion/ion chemistry.

Electrochemistry↗

Sonic spray as a dual polarity ion source for ion/ion reactions.

A single sonic spray source has been used to generate both positive and negative ions for subsequent ion/ion reaction experiments. Ion/ion reactions took place after ions of each polarity were sequentially injected into a linear ion trap, where axial trapping was effected by applying an auxiliary radio frequency voltage to one end lens. Absolute charge reductions via proton transfer were demonstrated for multiply charged protein/peptide cations and multiply charged oligonucleotide anions. Deprotonation of polypeptide cations occurs with anions derived from fluorinated compounds such as nonadecafluoro-1-decanol and perfluoro-1-octanol, while multiply charged oligonucleotide anions are efficiently protonated via reaction with proton sponge (N,N,N',N'-tetramethyl-1,8-naphthalenediamine) cations. No evidence for signal suppression of the biopolymer ions was noted to result from the presence of these reagents in the solution subjected to sonic spray. Several of the analytically useful applications of ion/ion proton-transfer reactions are demonstrated using a single sonic spray ion source. These include an ion parking experiment for the purpose of gas-phase ion concentration and charge-state reduction of product ions formed via beam-type and in-trap collision-induced dissociation of multiply charged oligonucleotide parent anions. Examples of complex formation are also given to illustrate the flexibility of the sonic spray-induced ion/ion reaction method.

Anions↗

Serology of severe acute respiratory syndrome: implications for surveillance and outcome.

BACKGROUND: Severe acute respiratory syndrome (SARS) is a novel infectious disease. No information is currently available on host-specific immunity against the SARS coronavirus (CoV), and detailed characteristics of the epidemiology of SARS CoV infection have not been identified. METHODS: ELISA was used to detect antibody to SARS CoV. Reverse-transcriptase polymerase chain reaction was used to detect SARS CoV RNA. T cells in peripheral blood of patients were quantified by flow cytometry. RESULTS: Of 36 patients with probable SARS CoV infection, 30 (83.3%) were positive for IgG antibody to SARS CoV; in contrast, only 3 of 48 patients with suspected SARS CoV infection, 0 of 112 patients with fever but without SARS, and 0 of 96 healthy control individuals were positive for it. IgG antibody to SARS CoV was first detected between day 5 and day 47 after onset of illness (mean +/- SD, 18.7+/-10.4). CONCLUSION: Detection of antibody to SARS CoV is useful in the diagnosis of SARS; however, at the incubation and initial phases of the illness, serological assay is of little value, because of late seroconversion in most patients.

Adult↗