A flexible sample introduction method for polymer microfluidic chips using a push/pull pressure pump.

A push/pull sample introduction method based on push/pull pressure flow for microfluidic systems (cross, double T and multichannel structures) is presented. This leads to well-defined and controllable sample plugs even when dealing with long channels. By tuning the relative push/pull pressure, it is shown that the size of the sample plug can effectively be controlled. Good signal reproducibility upon continued sample introduction and subsequent chip electrophoresis employing fluorescence detection is demonstrated for different chip geometries (i.e. short channels and long channels). Since the performance of the method is relatively insensitive to chip geometry, it is particularly useful for polymeric prototype microchips as tedious optimization is not required. Furthermore, the push/pull sample introduction is extended to multichannel chips thus demonstrating the possibilities of applying the methodology for realizing single chip high throughput sample analysis.

Equipment Design↗

Passive conductivity detection for capillary electrophoresis.

A passive electrochemical detection principle that can be applied to capillary electrophoresis is presented. The separation electrical field is used to generate a potential difference between two electrodes located along the channel. For constant-current electrophoresis, the generated signal is proportional to the resistance of the solution passing between the two electrodes. Contrary to conductivity detectors that are ac driven and need to be decoupled from the separation field, the passive detection directly takes advantage of the separation field. The signal is simply measured by a high-impedance voltmeter. The detection concept has been validated by numerical simulations showing how the magnitude of the signal is related to the ratio between the electrode distance and the length of the sample plug. As a proof of the principle, this detection concept has been demonstrated by the electrophoretic separation of three alkali ions on a polymer microchip. Based on preliminary results, a detection limit of 20 microM and a dynamic range of up to 3 orders of magnitude have been achieved.

Journal Article↗

Polyelectrolyte-modified short microchannel for cation separation.

Three alkali cations, potassium, sodium, and lithium, have been separated within 15 s in a 1 cm long polymer microchip. The separation microchannel is modified by a polycation, poly(allylammonium chloride), which makes the channel surfaces positively charged leading to a reversed electroosmotic flow (EOF) when compared to bare channels. Due to the decreased apparent mobility of the cations, the separation resolution is improved allowing the use of shorter channels.

Cations↗

Finite element simulation of pinched pressure-driven flow injection in microchannels.

A pinched pressure-driven flow injection on a microchip is numerically simulated in order to optimize the relative values of the operational parameters. The geometry studied is a two-dimensional rectangular channel featuring a cross-junction with a large depth-over-width ratio. The hydrodynamic and convection-diffusion equations are solved for the two steps of the process: first, the sample solution is pinched into the transversal channel (injection channel), and then it is injected into the longitudinal one (separation channel), where the time evolution of the concentration is analyzed for different types of the detectors. Electroosmotic flow calculations have also been performed and have shown a good agreement with literature. The results for pressure-driven flow point out that the shape of the detection signal is strongly dependent on the velocity in the separation channel and on the position of the detection probes. The so-called double-humped peak, caused by the parabolic flow profile at high driving flow rate is analyzed. A tight pinch greatly decreases the amount of injected sample and, consequently, the signal sensitivity without increasing its quality. A proper pullback of the sample during the separation process can decrease the tailing due to the sample leakage from the injection channel. Although a high sample pullback causes a considerable decrease in the signal sensitivity, it also greatly enhances the peak resolution. Finally, it is shown that a wider injection channel with high sample pullback ensures an improved signal sensitivity with good resolution.

Journal Article↗

Pressure pinched injection of nanolitre volumes in planar micro-analytical devices.

A new method for injecting and driving fluids by means of a multi-port injection valve and syringe pumps in a micro-channel network is described. A structure composed of two micro-channels arranged as a cross is connected with capillary tubes to an external multi-port injection valve. The fluid flows are driven by pressure and the multi-port valve controls the direction of the flow within the different sections of the structure. The first position of the multi-port valve allows the preparation of the loading of the sample, which is pinched in the cross section of the two micro-channels. The second position allows the precise injection of nL volumes. No dead volume exists between injection and separation modes. The system can be used to prepare a sample plug by pressure in order to perform chromatography with a broad range of buffered or non-buffered solutions. Thanks to the insensitivity to the ionic strength of the sample, this injection method is useful for the injection of complex biological samples in microchip analysis. In order to demonstrate the feasibility of the method, different solutions of ionic or fluorescent molecules were injected and detected in a photoablated planar polymer device.

Journal Article↗