PubMed Health⌕ Search

Biomedical subjects

Xiaoya Hu

Publications and source records attributed to Xiaoya Hu.

9 recordsLinked to original sources

Differential pulse voltammetric determination of nimesulide in pharmaceutical formulation and human serum at glassy carbon electrode modified by cysteic acid/CNTs base on electrochemical oxidation of L-cysteine.

Carbon nanotubes (CNTs) and cysteic acid based on electrochemical oxidation of L-cysteine (CySH) to form a novel composite thin film material at a glassy carbon electrode (GCE) for electroanalytical determination of nimesulide. The determination of nimesulide at the composite modified electrode with strong accumulation of nimesulide was studied by differential pulse voltammetry (DPV). The peak current obtained at +1.251 V (versus SCE) from DPV was linearly dependent on the nimesulide concentration in the range of 1.0 x 10(-7) -1.0 x 10(-5) M in 0.05 M H(2)SO(4) solution with a correlation coefficient of 0.997. The detection limit (S/N = 3) was found to be 5.0 x 10(-8) M. The low-cost modified electrode showed good sensitivity, selectivity, stability and had been applied to the determination of nimesulide in pharmaceutical formulation and human serum samples with satisfactory results.

Carbon↗

Preparation and evaluation of C18-bonded 1-microm silica particles for pressurized capillary electrochromatography.

Nonporous silica spheres (1 microm) were synthesized and bonded with octadecylsilane functionality. These stationary phase particles were packed electrokinetically into fused-silica capillaries with 100 microm id for a length of 20 cm, which was evaluated by using pressurized CEC (pCEC). The efficiency of the C18 RP column was characterized through the theoretical plates of thiourea, benzyl alcohol, toluene, styrene, and naphthalene. The effects of experimental parameters such as the applied voltage, sample size, pump flow rate, pH value and the concentration of the buffer solution, and the content of methanol in the mobile phase, on-column efficiency were evaluated. Column efficiency as high as 200 000 theoretical plates per meter for naphthalene was obtained with the optimal condition of 70% v/v methanol and 30% v/v of 10 mmol/L phosphate buffer (pH 7.8) at an applied voltage of 10 kV and a supplementary pressure of 500 psi.

Benzyl Alcohol↗

Etched bare fused-silica capillaries for online preconcentration of amino acids in CE.

An online preconcentration method based on electrostatic interaction between the analytes and inner surface of the capillary column was developed for the determination of zwitterionic analytes such as amino acids in CE coupled with a DAD. The amino acids possessed positive charges when they were dissolved in an acidic solvent. When they were injected into the column, they were attracted by the negatively charged inner surface of the fused-silica capillary column. An etched column was used to increase the area of the capillary's inner surface and, consequently increase the electrostatic interaction between the amino acids and the inner surface of the capillary column. It was found that when the sample was injected at 10 psi for 1 min and the pH value of the sample was 4, the amount of amino acids attracted to the inner surface of the capillary was maximum. Under these optimized experimental conditions, the detection sensitivity of CE-DAD was enhanced by 5200, 2800, and 3100 times for asparagine, tryptophan and phenylalanine, respectively, compared with normal CE separation. The method provided good reproducibility in terms of both migration time and peak height. It can be successfully used for the preconcentration zwitterion.

Amino Acids↗

Preparation of particle-fixed silica monoliths used in capillary electrochromatography.

Fused-silica capillarieswere packed with porous 1 microm bare silica microspheres and immobilized by potassium silicate-formamide in order to obtain columns with silica-based monolithic packing. After curing, the particle-fixed monolithic columns were octadecylated insitu with dimethyloctadecylchlorosilane. The columns were mechanically strong and permeable. No noticeable loss in efficiency was found after using a column continuously for 1 month. The performances of the particle-fixed silica monolithic columns were evaluated for CEC under RP conditions. High separation efficiency (about125 200 plates/m) was obtained by using these new types of columns.

Journal Article↗

Flow injection immunoassay for carcinoembryonic antigen combined with time-resolved fluorometric detection.

Time-resolved fluorescence has been developed for immunoassay to obtain higher sensitivity than usual immunoassays. In this paper, a simple, sensitive and specific method was developed for immunoassay of serum carcinoembryonic antigen (CEA) by combining time-resolved fluoroimmunoassay (TRFIA) and flow injection analysis. Based on a sandwich immunoassay format, a monoclonal antibody immobilized immunoaffinity column inserted in a flow system was used for immunoreactions. The cleaved solution was collected after the reaction between the immunocomplex in the immunoaffinity column and the enhancement solution that was used to cleave the Eu-labels from the immunocomplex, and then detected by time-resolved fluorescence. Serum CEA could be detected in the linear range from 2.5 to 100 ng/ml with a correlation coefficient of 0.997 and the detection limit of 1.0 ng/ml. Twenty human serum samples detected by this method were in good agreement with the results obtained by the electrochemiluminescence immunoassay. This method could be further developed for fast practical clinical detection of serum CEA levels.

Carcinoembryonic Antigen↗

Packing capilllary electrochromatography columns using vacuum--a preliminary study.

This paper introducesa novel method for packing Capillary Electrochromatography Columns (CEC). Using vacuum packing methodology, silica particles as small as 1 microm were successfully packed into the capillary columns with 75 microm inner diameter. The columns are verystable and show no noticeable loss in efficiency after 200 sample injections. The performance of these vacuum packed capillary columns was evaluated with a mixture of aromatic and non-aromatic compounds. A 24 cm long capillary column can produce peak efficiencies of around 45,000 plates for benzene.

Journal Article↗

Novel amperometric immunosensor for rapid separation-free immunoassay of carcinoembryonic antigen.

A novel immunosensor for rapid separation-free determination of carcinoembryonic antigen (CEA) in human serum is proposed. The immunosensor is prepared by co-immobilizing thionine and horseradish peroxidase (HRP)-labeled CEA antibody on a glassy carbon electrode (GCE) through covalently binding them to GCE with a glutaraldehyde (GA) linkage. The electrochemical behavior of the immobilized thionine displays a surface-controlled electrode process with an average electron transfer rate constant of 4.74+/-2.99 s(-1). It can be used as an electron transfer mediator for enzymatic activity detection of the HRP-labeled antibody to CEA. After the immunosensor is incubated with CEA solution at 23 degrees C for 40 min, the access of activity center of the HRP to thionine is partly inhibited, which leads to a linear decrease in the catalytic efficiency of the HRP to the oxidation of immobilized thionine by H(2)O(2) at -300 mV over two CEA concentration ranges from 0.5 to 3.0 and 3.0 to 167 ng/ml. Under optimal conditions, the detection limit for the CEA immunoassay is 0.1 ng/ml at three times background noise. The immunosensor shows good accuracy and acceptable storage stability, precision and reproducibility with intra-assay CVs of 6.1% and 5.8% at 2.5 and 50 ng/ml CEA, respectively, and an inter-assay CV of 6.3% at 50 ng/ml. This method is economical and shortens the analytical time, making it potentially attractive for clinical immunoassays.

Antibodies↗

Chemiluminescent immunosensor for CA19-9 based on antigen immobilization on a cross-linked chitosan membrane.

A novel chemiluminescent immunosensor for carbohydrate antigen 19-9 (CA19-9) based on the immobilization of CA19-9 on the cross-linked chitosan membrane was developed. The different membranes were characterized by atomic force microscopy (AFM) and infrared spectrum, respectively. Based on a noncompetitive immunoassay format, this proposed chemiluminescent immunosensor enabled a low-cost, flexible and rapid determination for CA19-9 in combination with flow injection analysis (FIA). After an off-line incubation of the analyte CA19-9 with horseradish peroxidase (HRP)-labeled anti-CA19-9, the mixture was injected into the immunosensor, which led to the trapping of free HRP-labeled anti-CA19-9 by the immobilized antigen in the immunosensor. The trapped HRP-labeled antibody was detected by chemiluminescence due to its catalytic activity following the reaction of luminol and H2O2. Under optimal conditions, the decreased chemiluminescent signal of the immunosensor was proportional to the CA19-9 concentration in the range of 2.0-25 U/ml with a detection limit of 1.0 U/ml. The immunosensor showed an acceptable accuracy and good reproducibility. The results of 20 human serum samples detected by this method were in acceptable agreement with those obtained by immunoradiometric assay. The proposed immunosensor provided a new promising tool for practical clinical detection of the serum CA19-9 level.

Antibodies↗