Novel coupling mechanism-based imaging approach to scanning electrochemical microscopy for probing the electric field distribution at the microchannel end.

A novel coupling mechanism-based imaging approach to scanning electrochemical microscopy (SECM) was used to image the distribution of electric field at the end channel of a poly(dimethylsiloxane) (PDMS) capillary electrophoresis (CE) microchip in the absence of redox species. The coupling imaging mechanism was systematically investigated and qualitatively illustrated. It was proved that the distribution of solution potentials within the scanning plane caused a different reduction rate of water at the tip electrode, which led to the variation in tip current. Within the scanning plane, the solution potentials measured in the central area of the microchannel were usually higher than those measured outside. The SECM images showed a strong dependence on tip potential, tip-to-channel distance, and separation potential. According to the Tafel equation, SECM images were converted to parameters that directly showed the distribution of solution potential. Change in the solution potential along the central axial line of the microchannel was also continuously sensed by allowing the tip to approach the microchannel in the presence of high voltage. Using dopamine as a model compound, the effect of solution potential on electrochemical detection was estimated by detecting separation parameters.

Dimethylpolysiloxanes↗

Off-line form of the Michaelis-Menten equation for studying the reaction kinetics in a polymer microchip integrated with enzyme microreactor.

We firstly transformed the traditional Michaelis-Menten equation into an off-line form which can be used for evaluating the Michaelis-Menten constant after the enzymatic reaction. For experimental estimation of the kinetics of enzymatic reactions, we have developed a facile and effective method by integrating an enzyme microreactor into direct-printing polymer microchips. Strong nonspecific adsorption of proteins was utilized to effectively immobilize enzymes onto the microchannel wall, forming the integrated on-column enzyme microreactor in a microchip. The properties of the integrated enzyme microreactor were evaluated by using the enzymatic reaction of glucose oxidase (GOx) with its substrate glucose as a model system. The reaction product, hydrogen peroxide, was electrochemically (EC) analyzed using a Pt microelectrode. The data for enzyme kinetics using our off-line form of the Michaelis-Menten equation was obtained (K(m) = 2.64 mM), which is much smaller than that reported in solution (K(m) = 6.0 mM). Due to the hydrophobic property and the native mesoscopic structure of the poly(ethylene terephthalate) film, the immobilized enzyme in the microreactor shows good stability and bioactivity under the flowing conditions.

Enzyme Stability↗

Microchannel-electrode alignment and separation parameters comparison in microchip capillary electrophoresis by scanning electrochemical microscopy.

The end of separation channel in a microchip was electrochemically mapped using the feedback imaging mode of scanning electrochemical microscopy (SECM). This method provides a convenient way for microchannel-electrode alignment in microchip capillary electrophoresis. Influence of electrode-to-channel positions on separation parameters in this capillary electrophoresis-electrochemical detection (CE-ED) was then investigated. For the trapezoid shaped microchannel, detection in the central area resulted in the best apparent separation efficiency and peak shape. In the electrode-to-channel distance ranging from 65 to 15mum, the limiting peak currents of dopamine increased with the decrease of the detection distance due to the limited diffusion and convection of the sample band. Results showed that radial position and axial distance of the detection electrode to microchannel was important for the improvement of separation parameters in CE amperometric detection.

Automation↗

Facile synthesis of hollow carbon nanospheres from hollow chitosan nanospheres.

Hollow carbon nanospheres (HCNS) with large surface area were synthesized from hollow chitosan nanospheres by one-step pyrolysis with a relatively low temperature (550 degrees C). The resulted HCNS is fully carbonized and partially graphitized under the experiment conditions. It is an important and facile method to prepare the uniform, shape- and size-controlled carbon nanomaterials by carbonization of the natural polysaccharide compounds and their derivatives. The as-prepared HCNS has a narrow size distribution in hollow carbon nanospheres (about 53 nm). The structure and size of HCNS are reproducible and could be tunable by changing the preparation conditions. The characterizations to estimate the composition, decompose properties, crystalline form, structure and surface property of the HCNS were investigated using FT-IR spectroscopy, thermogravimetric analysis (TGA), X-ray diffraction measurement (XRD), transmission electron microscopy (TEM) analysis, and the N2 adsorption-desorption isothermal process. The present preparation method makes it feasible to synthesize carbon nanospheres in abundance in the lab, and the synthesized HCNS could be a promising support for metal catalysts, an ideal matrix connecting with DNA or other bioactive substances.

Chitosan↗

Characterization and manipulation of the electroosmotic flow in porous anodic alumina membranes.

Porous anodic alumina membranes (PAAMs) have uniform and high-density nanopores, and the dimension and interval of the pores can be easily controlled by varying the anodization conditions. The application of PAAMs could widely impact the cost and efficiency of the liquid-based nanoscale separations. We report here the property of electroosmotic flow in PAAMs, which plays a significant role in the mass transport across these membranes that have charged pore surfaces. By controlling the solution pH and the magnitude and sign of the applied current, the mass transport through these nanoporous membranes can be spatially and temporally manipulated. The effects of electrosurface properties and electrolyte ionic strength on electroosmotic flow were studied. The anion incorporation and adsorption cause the variation of the electrosurface properties of PAAMs, which in turn influence the rate and direction of the mass transport. As compared to the membrane with fixed surface charge, this diversity makes it possible for the PAAMs to be used in various conditions.

Journal Article↗

Biocomposites of covalently linked glucose oxidase on carbon nanotubes for glucose biosensor.

The formation of covalently linked composites of multi-walled carbon nanotubes (MWCNT) and glucose oxidase (GOD) with high-function density for use as a biosensing interface is described. The reaction intermediates and the final product were characterized by using FT-IR spectroscopy, and the MWCNT-coated GOD nanocomposites were examined by atomic force microscopy (AFM) and transmission electron microscopy (TEM). Interestingly, it was found that the GOD-MWCNT composites are highly water soluble. Electrochemical characterization of the GOD-MWCNT composites that were modified on a glassy carbon electrode shows that the covalently linked GOD retains its bioactivity and can specifically catalyze the oxidation of glucose. The oxidation current shows a linear dependence on the glucose concentration in the solution in the range of 0.5-40 mM with a detection limit of 30 microM and a detection sensitivity of 11.3 microA/mMcm2. The present method may provide a way to synthesize MWCNT related composites with other biomolecules and for the construction of enzymatic reaction-based biofuel cells and biosensors.

Biosensing Techniques↗

Simple method for the separation and detection of native amino acids and the identification of electroactive and non-electroactive analytes.

Detection of native amino acids was accomplished using a capillary electrophoresis (CE)-amperometric detection system, in which a single carbon fiber cylinder (CFC) working electrode instead of a carbon fiber disc (CFD) electrode was mounted in the end part of a poly(dimethylsiloxane) (PDMS)/glass hybrid microchannel. Similar to that using CFD working electrode, here, the electrochemical reduction reaction at the working electrode is also coupled from the separation high voltage system, the coupling degree is related to the in-channel length of the CFC. This property simplifies the fabrication procedure of the working electrode and also provides a convenient and sensitive means for the determination of non-electroactive ions by amperometry. The present detection mode is successfully used to electrochemically detect non-electroactive arginine (Arg), threonine (Thr), glutamic acid (Glu) and electroactive cysteine (Cys). Furthermore, by simply changing the detection potential, we can easily distinguish peak mobilities of electroactive amino acids from that of non-electroactive amino acids.

Amino Acids↗

Electrokinetic control of fluid in plastified laser-printed poly(ethylene terephthalate)-toner microchips.

The application of plastified laser-printed poly(ethylene terephthalate)(PET)-toner microchips to capillary electrophoresis was investigated. Electroosmotic flow was observed in the direction of the cathode for the buffer system studied (phosphate, pH 3-10). Average electroosmotic mobilities of 1.71 x 10(-4) to 4.35 x 10(-4) cm(2) V(-1) s(-1) were observed from pH 3 to 10. This variation suggests that silica fillers in the toner and on the surface of the polymer dominate the zeta potential of the material, which is also confirmed by XPS measurements. Dopamine and catechol were used as model analytes for microchip electrophoresis in combination with electrochemical detection. Results show that these two analytes can be efficiently separated and detected electrochemically with the plastified laser-printed PET-toner microchips.

Journal Article↗

Nonenzymatic glucose detection by using a three-dimensionally ordered, macroporous platinum template.

A three-dimensionally ordered, macroporous, inverse-opal platinum film was synthesized electrochemically by the inverted colloidal-crystal template technique. The inverse-opal film that contains platinum nanoparticles showed improved electrocatalytic activity toward glucose oxidation with respect to the directly deposited platinum; this improvement is due to the interconnected porous structure and the greatly enhanced effective surface area. In addition, the inverse-opal Pt-film electrode responds more sensitively to glucose than to common interfering species of ascorbic acid, uric acid, and p-acetamidophenol due to their different electrochemical reaction mechanisms. Results showed that the ordered macroporous materials with enhanced selectivity and sensitivity are promising for fabrication of nonenzymatic glucose biosensors.

Electrodes↗

A dual-electrode approach for highly selective detection of glucose based on diffusion layer theory: experiments and simulation.

A dual-electrode configuration for the highly selective detection of glucose in the diffusion layer of the substrate electrode is presented. In this approach, a glassy carbon electrode (GCE, substrate) modified with a conductive layer of glucose oxidase/Nafion/graphite (GNG) was used to create an interference-free region in its diffusion layer by electrochemical depletion of interfering electroactive species. A Pt microelectrode (tip, 5 microm in radius) was located in the diffusion layer of the GNG-modified GCE (GNG-G) with the help of scanning electrochemical microscopy. Consequently, the tip of the electrode could sense glucose selectively by detecting the amount of hydrogen peroxide (H2O2) formed from the oxidization of glucose on the glucose oxidase layer. The influences of parameters, including tip-substrate distance, substrate potential, and electrolyzing time, on the interference-removing efficiency of this dual-electrode approach have been investigated systematically. When the electrolyzing time was 30 s, the tip-substrate distance was 1.8 a (9.0 microm) (where a is the radius of the tip electrode), the potentials of the tip and substrate electrodes were 0.7 V and 0.4 V, respectively, and a mixture of ascorbic acid (0.3 mM), uric acid (0.3 mM), and 4-acetaminophen (0.3 mM) had no influence on the glucose detection. In addition, the current-time responses of the tip electrode at different tip-substrate distances in a solution containing interfering species were numerically simulated. The results from the simulation are in good agreement with the experimental data. This research provides a concept of detection in the diffusion layer of a substrate electrode, as an interference-free region, for developing novel microelectrochemical devices.

Carbon↗

Selective glucose detection based on the concept of electrochemical depletion of electroactive species in diffusion layer.

A glucose detection approach based on the concept of electrochemical depletion of electroactive species in diffusion layer was established, using scanning electrochemical microscopy (SECM). By controlling the glucose oxidase (GOD) modified electrode (substrate electrode) at a proper potential of electrochemical oxidation of interfering electroactive species, i.e., ascorbic acid (AA), an interference-free microcircumstance was formed in the diffusion layer of the substrate electrode. Consequently, we could successfully sense hydrogen peroxide generated from an enzymatic reaction by locating a Pt ultramicroelectrode (UME) (tip electrode, 5 microm in radius) into the diffusion layer of the substrate electrode. Properties of this interference-removing approach based on electrochemical depletion were systematically investigated. Results showed that the interference-removing efficiency was significantly determined by the tip-substrate distance and substrate potential. When the tip-substrate distance was 11 microm (2.2 times of the tip electrode radius) and the substrate potential was 0.5 V, nearly 90% of AA (0.5 mM) could be depleted within 30s without consumption of H2O2. Under these conditions, 0.1 mM AA showed no influence on the detection of 0.5 mM glucose. The linear range of glucose detection is 0.01-1 mM with a detection limit (DL) of 0.005 mM (correlation coefficient is 0.9948). This research will open a new way for developing selective micro-biosensors.

Biosensing Techniques↗

In-channel indirect amperometric detection of nonelectroactive anions for electrophoresis on a poly(dimethylsiloxane) microchip.

In the present paper, we describe a microfluidics-based sensing system for nonelectroactive anions under negative separation electric field by mounting a single carbon fiber disk working electrode (WE) in the end part of a poly(dimethylsiloxane) microchannel. In contrast to work in a positive separation electric field described in our previous paper (Anal. Chem. 2004, 76, 6902-6907), here the electrochemical reduction reaction at the WE is not coupled with the separation high-voltage (HV) system, whereas the electrochemical oxidation reaction at the WE is coupled with the separation HV system. The electroactive indicator is the carbon fiber WE itself but not dissolved oxygen. This provides a convenient and sensitive means for the determination of nonelectroactive anions by amperometry. The influences of separation voltage, detection potential, and the distance between the WE and the separation channel outlet on the response of the detector have been investigated. The present detection mode is successfully used to electrochemically detect F-, Cl-, SO4(2-), CH3COO-, H2PO4-. Based on the preliminary results, a detection limit of 2 microM and a dynamic range up to three orders of magnitude for Cl- could be achieved.

Anions↗

Electrochemical detection method for nonelectroactive and electroactive analytes in microchip electrophoresis.

In this work, we establish an indirect amperometric detection method via mounting a single carbon fiber disk working electrode in the end part of a microchannel. This in-channel configuration for microchip capillary electrophoresis brings about that the potential of the working electrode in the case of electrochemical reduction reaction is coupled by the separation electric field, while the potential of the working electrode in the case of electrochemical oxidation reaction is not coupled by the separation electric field. Such a special performance provides a convenient and sensitive approach for indirectly detecting nonelectroactive analytes that relies on amperometric response of dissolved oxygen in solution and directly detecting electroactive analytes based on their own amperometric response on the carbon fiber electrode. This method has shown its essential importance in the analysis of inorganic cations, biomolecules, and electroosmotic flow rates. Based on preliminary results, a detection limit of 1.0 microM for K(+) and Na(+) have been achieved.

Carbon↗

Electrochemical detector for microchip electrophoresis of poly(dimethylsiloxane) with a three-dimensional adjustor.

This paper presents an electrochemical detector for poly(dimethylsiloxane) (PDMS) microchip CE with a three-dimensional adjustor which makes it possible to accurately align a separate working electrode that can be easily fabricated in laboratory to the uncertain PDMS microchannel outlet. The substantial influence of the electrode-PDMS microchannel distance was investigated. The optimal electrode-outlet distance was found to be 10 microm for the PDMS microchannel with the width of 50 microm due to its relatively slow electroosmotic flow. Adrenaline and catechol were well separated, with a linear response range from 20 microM to 1 mM, and a detection limit of 2 microM for catechol, using carbon disk electrode (diameter of 300 microm). Furthermore, arginine and histidine can be well separated and detected directly in the PDMS microchannel using a Cu disk electrode (diameter of 150 microm).

Dimethylpolysiloxanes↗