PubMed Health⌕ Search

Biomedical subjects

Xiuzhong Wang

Publications and source records attributed to Xiuzhong Wang.

3 recordsLinked to original sources

Physically accurate mesh simulation in a laparoscopic hernia surgery simulator.

In this paper we use the 2D angular spring based mass-spring-damper (AMSD) model to simulate the plastic mesh in a laparoscopic hernia surgery simulator. We propose a physically based method to systematically derive the optimal parameters of the 2D AMSD model. While the traditional 2D MSD model lacks resistance against bending, the 2D AMSD model with optimized parameters can provide correct bending resistance as well as stretching resistance. The simulated mesh is demonstrated to be much more realistic.

Algorithms↗

Simultaneous determination of dopamine and ascorbic acid at a poly(toluidine blue) modified electrode.

A novel polymer modified electrode is discussed in this paper. This resulting electrode can catalyze remarkably toward the electrochemical oxidations of dopamine (DA) and ascorbic acid (AA). Moreover, it can clearly discriminate the electrochemical oxidations of DA from that of AA based on their semi-derivative voltammograms. Hence, a simultaneous determination of DA and AA based on semi-derivative voltammetry at a poly(toluidine blue) modified electrode is suggested. The detection linear range for DA is 0.4 micromol L(-1)-1.5 mmol L(-1), and AA 0.2 micromol L(-1)-2.4 mmol L(-1), respectively. The resulting modified electrode was tentatively used to determine DA and AA in brain tissue.

Journal Article↗

Flow-injection analysis and voltammetric detection of NADH with a poly-Toluidine Blue modified electrode.

Poly-Toluidine Blue film was prepared by electrooxidative polymerization at a glassy carbon electrode in a phosphate buffer solution. The resulting chemically modified electrode (CME) exhibited excellent electrocatalysis toward the oxidation of reduced nicotinamide coenzyme (NADH) with over a 450 mV decrease of the overpotential compared with that at a bare glassy carbon electrode. Two electrochemical determinations of NADH, cyclic voltammetry and flow injection analysis, were established based on the electrocatalytical performance of the resulting modified electrode. Under an identical determinate condition, the voltammetric detection for NADH gave a detection limit of 3.3 micromol L(-1) with a linear concentration range of 9.1 micromol L(-1) to 1.8 mmol L(-1). As a detector in a flow-injection system, the CME gave a detection limit of 0.1 micromol L(-1) for NADH with a linear concentration range of 1.0 micromol L(-1) to 3.2 mmol L(-1). Obviously, flow-injection analysis is superior to voltammetric detection in NADH determination for its lower detection limit and wider detectable linear range.

Journal Article↗