Phase-space formulation for phase-contrast x-ray imaging.

Phase-space formulation based on the Wigner distribution has been presented for analyzing phase-contrast image formation. Based on the statistical nature and affine canonical covariance of Wigner distributions in the phase space, we show that the partial coherence effects of incident x-ray wave field on image intensity are simply accounted for by a multiplication factor, which is the reduced complex degree of coherence of the incident x-ray wave field. We show especially that with the undulator sources one cannot obtain the phase-contrast intensity by summing over the contributions from all electron positions, since the van Cittert-Zernike theorem fails in general for undulators. We derive a comprehensive formula that quantifies the effects of partial spatial coherence, polychromatic spectrum, body attenuation, imaging-detector resolution, and radiation dose on phase-contrast visibility in clinical imaging. The results of our computer modeling and simulations show how the formula can provide design guidelines and optimal parameters for clinical x-ray phase-contrast imaging systems.

Algorithms↗

X-ray phase-attenuation duality and phase retrieval.

Phase retrieval is the key to quantitative x-ray phase-contrast imaging. To retrieve the phase image of an x-ray wave field, in general one needs multiple phase-contrast images. We have made a new observation of phase-attenuation duality for soft tissues, and we show how only a single phase-contrast image is needed for successful phase retrieval based on this duality. The phase-retrieval formula based on a single phase-contrast image of inhomogeneous soft tissue is derived and presented. We show the striking enhancement of the tissue contrast in simulated phase images that this new approach produces.

Algorithms↗

Thickness of molybdenum filter and squared contrast-to-noise ratio per dose for digital mammography.

OBJECTIVE: The objective of our study was to test whether the lesion-tissue contrast-to-noise ratio (CNR) at a given dose level can be improved by increasing the thickness of the molybdenum (Mo) filter currently used in digital mammography. MATERIALS AND METHODS: We studied how the CNR between breast and a 5-mm simulated infiltrating ductal carcinoma (IDC) embedded in a 5-cm-thick breast changes with Mo filter thickness. We performed phantom imaging experiments by modifying the filter wheel of a Senographe 2000D unit with Mo filters that ranged from 15 to 90 microm in thickness. A 5-cm-thick 50% glandular-50% adipose breast phantom with a 5-mm insert simulating IDC was used as the phantom for all the cases. The CNRs between the breast phantom and the IDC insert were measured, and average glandular doses were calculated using a filtration-dependent X-ray spectra model and a breast dosimetry model based on a validated Monte Carlo simulation. RESULTS: The lesion-tissue CNR at a given dose level increases with increasing Mo filter thickness from 15 to 90 microm. The measured squared CNR per dose increased by 8%, 14%, 17%, and 17% for 45-, 60-, 75-, and 90-microm Mo filters, respectively, compared with the standard 30-microm Mo filter. Meanwhile, the exposure times were increased by 35% (45 microm), 71% (60 microm), 177% (75 microm), and 229% (90 microm). CONCLUSION: Increasing Mo filter thickness from 30 to 60 microm can increase lesion-tissue squared CNR per dose by 14% with a tolerable increase in the duration of exposure.

Breast Neoplasms↗

A new theory of phase-contrast x-ray imaging based on Wigner distributions.

There is a pressing need for a comprehensive theory for phase-contrast x-ray imaging to guide its development and clinical applications. This work presents such a theory as the foundation for deriving these guidelines. The new theory is based on the Wigner-distributions for the parabolic wave equations, and it is more general than the present theories based on the Fresnel-Kirchhoff diffraction theory. The new theory shows for the first time how the complex degree of coherence (CDC) of the incident x-ray beam determines the phase-contrast visibility in general, and how the reduced complex degree of coherence (RCDC) for an anode-source is equal to the system's optical transfer function for geometric unsharpness in particular. The role of detector resolution in phase visibility has been clarified as well. Computer simulations based on the new theory were conducted and optimal design parameters were derived for phase-contrast mammography systems.

Algorithms↗

Clinical implementation of x-ray phase-contrast imaging: theoretical foundations and design considerations.

Theoretical foundation and design considerations of a clinical feasible x-ray phase contrast imaging technique were presented in this paper. Different from the analysis of imaging phase object with weak absorption in literature, we proposed a new formalism for in-line phase-contrast imaging to analyze the effects of four clinically important factors on the phase contrast. These are the body parts attenuation, the spatial coherence of spherical waves from a finite-size focal spot, and polychromatic x-ray and radiation doses to patients for clinical applications. The theory presented in this paper can be applied widely in diagnostic x-ray imaging procedures. As an example, computer simulations were conducted and optimal design parameters were derived for clinical mammography. The results of phantom experiments were also presented which validated the theoretical analysis and computer simulations.

Computer Simulation↗