Field amplified sample stacking coupled with chip-based capillary electrophoresis using negative pressure sample injection technique.

A multi-T microchip for integrated field amplified sample stacking (FASS) with CE separation to increase the chip-based capillary electrophoresis (chip-based CE) sensitivity was developed. Volumetrically defined large sample plug was formed in one step within 5s by the negative pressure in headspace of the two sealed sample waste reservoirs produced using a syringe pump equipped with a 3-way valve. Stacking and separation can proceed only by switching the 3-way valve to release the vacuum in headspace of the two sample waste reservoirs. This approach considerably simplified the operations and the equipments for FASS in chip-based CE systems. Migration time precisions of 3.3% and 1.3% RSD for rhodamine123 (Rh123) and fluorescien sodium salt (Flu) in the separation of a mixture of Flu and Rh123 were obtained for nine consecutive determinations with peak height precisions of 4.8% and 3.4% RSD, respectively. Compared with the chip-based CE on the cross microchip, the sensitivity for analysis of FlTC, FITC-labeled valine (Val) and Alanine (Ala) increased 55-, 41- and 43-fold, respectively.

Alanine↗

Intracellular labeling method for chip-based capillary electrophoresis fluorimetric single cell analysis using liposomes.

An intracellular derivatization method mediated by liposome was developed for single cell analysis with chip-based capillary electrophoresis (CE) and laser-induced fluorescence (LIF) detection. Liposomes with an average diameter of 100 nm were produced from phosphatidylcholine to encapsulate fluorescent dyes by an ultrasonic method. The encapsulation yield and the vesicle density were determined to be 46+/-5% and 8.8 x 10(14)/mL, respectively. The amount of fluorescent dye that entered the cells was dependent on the duration of incubating cells with liposomes, liposome density, and concentration of the dye solution encapsulated in liposomes. The described method introduced cell membrane nonpermeable fluorescent dyes into living cells without reducing cell viability. Single cell analysis using microfluidic chip-based CE revealed that liposome-membrane fusion occurred after entrance of liposomes into the cells, with release of encapsulated fluorescence dyes and labeling of intracellular species.

Cells↗

Determination of reactive oxygen species in single human erythrocytes using microfluidic chip electrophoresis.

Reactive oxygen species (ROS) are known to not only mediate the damage of cellular constituents but also to regulate cellular signaling. Analysis of ROS is essential if we wish to understand the mechanisms of cellular alterations. In this paper, a microfluidic chip-based approach to the determination of ROS in single erythrocyte was developed by using a simple crossed-channel glass chip with integrated operational functions, including cell sampling, single cell loading, docking, lysing, and capillary electrophoretic (CE) separation with laser-induced fluorescence (LIF) detection. Non-fluorescent dihydrorhodamine 123 (DHR 123), which can be oxidized intracellularly by ROS to the fluorescent rhodamine 123 (Rh 123), was used as the fluorogenic reagent. The effect of pH on the migration time of Rh 123 and detection sensitivity was discussed. The present method minimized dilution of intracellular ROS during reaction with DHR 123 and determination. As a result, an extremely low detection limit of 0.8 amol has been achieved. The time required for complete analysis of one human erythrocyte was less than 3 min. A migration time precision of 4.1% RSD was obtained for six consecutively-injected cells. Upon stimulation with 4 mmol/l H2O2 for 10 min, the intracellular ROS concentration was found to increase on average by about a factor of 8.4.

Calibration↗

Microfluidic chip-based liquid-liquid extraction and preconcentration using a subnanoliter-droplet trapping technique.

A robust and simple approach for microfluidic liquid-liquid (L-L) extraction at the subnanoliter-scale was developed for on-chip sample pretreatment. Organic solvent droplets of a few hundred pL were trapped within micro recesses fabricated in the channel walls of a microfabricated glass chip. L-L extraction was performed by delivering aqueous samples through the channel, with the sample stream continuously flowing adjacent to the droplets. The analytes in aqueous streams were enriched within the droplet with high preconcentration factors owing to both phase transfer and dissolution of organic solvent into the bypassing aqueous sample. An aqueous solution of butyl rhodamine B (BRB) and 1-hexanol were used, respectively, as sample and extractant to demonstrate the performance of the system. The fluorescence intensity of the dye extracted into the droplet was monitored in situ by LIF. The system proved to be an efficient means for achieving high enrichment factors of over 1000, with sample consumption of a few microL. Quantitative measurement of the extracted analyte was achieved with a linear response in the range 1 x 10(-9)-8 x 10(-7) M BRB. The precision of the measured fluorescence values for a 10(-7) M BRB standard with a 12.5 min preconcentration period was 6.6% RSD (n = 5).

Journal Article↗

DNA separation with low-viscosity sieving matrix on microfabricated polycarbonate microfluidic chips.

Microfluidic devices have been fabricated on polycarbonate (PC) substrates by use of a hot embossing method using a silicon master template. By adding auxiliary lines around the functional channel on the silicon master, its lifetime was significantly prolonged and the bonding strength of the PC cover plate to the microfluidic chip was greatly improved. More than 300 polycarbonate microfluidic chips have been replicated with the same silicon mold. CE separation of Phi X-174/HaeIII DNA restriction fragments, with high resolution efficiency and good reproducibility, was achieved on these devices using the low-viscosity sieving matrix HPMC-50. Temperature was found to have a significant effect on separation efficiency.

Bacteriophage phi X 174↗

Simultaneous determination of glutathione and reactive oxygen species in individual cells by microchip electrophoresis.

A microchip electrophoresis method was developed for simultaneous determination of reactive oxygen species (ROS) and reduced glutathione (GSH) in the individual erythrocyte cell. In this method, cell sampling, single-cell loading, docking, lysing, and capillary electrophoretic separation with LIF detection were integrated on a microfluidic chip with crossed channels. ROS was labeled with dihydrorhodamine 123 in the intact cell, while GSH was on-chip labeled with 2,3-naphthalene-dicarboxaldehyde, which was included in the separation medium. On-chip electrical lysis, characterized by extremely fast disruption of the cellular membrane (<40 ms), was exploited to minimize enzymatic effects on analyte concentrations during the determination. The microfluidic network was optimized to prevent cell leaking from the sample reservoir (S) into separation during the separation phase. The structure of the S was modified to avoid blockage of its outlet by deposited cells. Detection limits of 0.5 and 6.9 amol for ROS and GSH, respectively, were achieved. The average cell throughput was 25 cells/h. The effectiveness of the method was demonstrated in the simultaneous determination of GSH and ROS in individual cells and the variations of cellular GSH and ROS contents in response to external stimuli.

Adult↗

Performance of PAHs emission from bituminous coal combustion.

Carcinogenic and mutagenic polycyclic aromatic hydrocarbons (PAHs) generated in coal combustion have caused great environmental health concern. Seventeen PAHs (16 high priority PAHs recommended by USEPA plus Benzo[e]pyrene) present in five raw bituminous coals and released during bituminous coal combustion were studied. The effects of combustion temperature, gas atmosphere, and chlorine content of raw coal on PAHs formation were investigated. Two additives (copper and cupric oxide) were added when the coal was burned. The results indicated that significant quantities of PAHs were produced from incomplete combustion of coal pyrolysis products at high temperature, and that temperature is an important causative factor of PAHs formation. PAHs concentrations decrease with the increase of chlorine content in oxygen or in nitrogen atmosphere. Copper and cupric oxide additives can promote PAHs formation (especially the multi-ring PAHs) during coal combustion.

Air Pollutants↗

Integration of single cell injection, cell lysis, separation and detection of intracellular constituents on a microfluidic chip.

A microfluidic system was developed for the analysis of single biological cells, with functional integration of cell sampling, single cell loading, docking, lysing, and capillary electrophoretic (CE) separation with laser induced fluorescence (LIF) detection in microfabricated channels of a single glass chip. Channels were 12 microm deep and 48 microm wide, with a simple crossed-channel design. The effective separation channel length was 35 mm. During sampling with a cell suspension (cell population 1.2 x 10(5) cells per mL in physiological salt solution), differential hydrostatic pressure (created by adjusting liquid levels in the four reservoirs) was used to control cell flow exclusively through the channel crossing. Single cell loading into the separation channel was achieved by electrophoretic means by applying a set of potentials at the four reservoirs, counteracting the hydrostatic flow. A special docking (adhering) procedure for the loaded cell was applied before lysis by repeatedly connecting and disconnecting a set of low potentials, allowing precise positioning of the cell within the separation channel. Cell lysis was then effected within 40 ms under an applied CE separation voltage of 1.4 kV (280 V cm(-1)) within the working electrolyte (pH 9.2 borate buffer) without additional lysates. The docked lysing approach reduced dispersion of released intracellular constituents, and significantly improved the reproducibility of CE separations. Glutathione (GSH) was used as a model intracellular component in single human erythrocyte cells. NDA derivatized GSH was detected using LIF. A throughput of 15 samples h(-1), a retention time precision of 2.4% RSD was obtained for 14 consecutively injected cells. The average cellular concentration of GSH in human erythrocytes was found to be 7.2 [times] 10(-4)+/- 3.3 x 10(-4) M (63 +/- 29 amol per cell). The average separation efficiency for GSH in lysed cells was 2.13 x 10(6)+/- 0.4 x 10(6) plates per m, and was about a factor of 5 higher than those obtained with GSH standards using pinched injection.

Electrophoresis, Capillary↗