Validating volume flow measurements from a novel semiautomated four-dimensional Doppler ultrasound scanner.

RATIONALE AND OBJECTIVES: Accurate measurement of blood volume flow (in ml/min) is an important clinical goal. This project compared in vitro and in vivo volume flow measurements obtained with a novel, real-time three-dimensional (i.e., four-dimensional) ultrasound scanner (Encore PV; Vuesonix Sensors, Wayne, PA) with those from an invasive transit time flowmeter. MATERIALS AND METHODS: A flow pump was used to generate pulsatile flow rates from 60 to 600 ml/min. The Encore detected absolute blood velocity vectors within a volume. The scanner determined the centerline of the vessel and volume flow was then automatically calculated. Results were compared with those of an invasive technique for volumetric blood flow measurements utilizing a transit-time flowmeter (TS420; Transonic Systems Inc., Ithaca, NY). In vivo, 10 second datasets of the volume flow in the distal aorta of six rabbits were obtained simultaneously with the Encore PV and the flowmeter. Data were compared using linear regression and Bland-Altman analysis (due to the lack of independence). RESULTS: In vitro, Encore and flowmeter measurements both matched the flow pump (r2 > 0.99; P < .0001) with mean errors of -11.8% and -0.3%, respectively. Marked underestimation of the true flow rates was encountered with the Encore at the lowest pump setting. In vivo mean volume flows between 10.6 and 79.3 ml/min were measured. Mean and maximum volume flows obtained with the two techniques correlated significantly (P < .0001) with r2 values of 0.86 and 0.62, respectively. The corresponding root-mean-square errors were 6.9% for mean flow and 61.2% for maximum volume flow measurements. CONCLUSION: A new semiautomated four-dimensional Doppler device has been tested in vitro and in vivo. Mean volume flow measurements with this unit are comparable to those of an invasive flowmeter.

Blood Flow Velocity↗

In vivo perfusion estimation using subharmonic contrast microbubble signals.

OBJECTIVE: The purpose of this study was to quantify perfusion in vivo using contrast-enhanced subharmonic imaging (SHI). METHODS: A modified LOGIQ 9 scanner (GE Healthcare, Milwaukee, WI) operating in gray scale SHI mode was used to measure SHI time-intensity curves in vivo. Four dogs received intravenous contrast bolus injections (dose, 0.1 mL/kg), and renal SHI was performed. After 3 contrast agent injections, a microvascular staining technique based on stable (nonradioactive) isotope-labeled microspheres (BioPhysics Assay Laboratory Inc, Worcester, MA) was used to quantify the degree of perfusion in 8 sections of each kidney. Low perfusion states were induced by ligating surgically exposed segmental renal arteries followed by contrast agent injections and microvascular staining. Digital clips were transferred to a personal computer, and SHI time-intensity curves were acquired in each section using Image-Pro Plus software (Media Cybernetics, Silver Spring, MD). Subharmonic fractional blood volumes were calculated, and the perfusion was estimated from the initial slope of the fractional blood volume uptake averaged over 3 injections. Subharmonic perfusion data were compared with the gold standard (ie, the microspheres) using linear regression analysis. RESULTS: In vivo gray scale SHI clearly showed flow and, thus, perfusion in the kidneys with almost complete suppression of tissue signals. In total, 270 SHI time-intensity curves were acquired, which reduced to 94 perfusion estimates after averaging. Subharmonic perfusion estimates correlated significantly with microsphere results (r = 0.57; P < .0001). The best SHI perfusion estimates occurred for high perfusion states in the anterior of the kidneys (r = 0.73; P = .0001). The corresponding root mean square error was 2.4%. CONCLUSIONS: Subharmonic perfusion estimates have been obtained in vivo. The perfusion estimates were in reasonable to good agreement with a microvascular staining technique.

Albumins↗