PubMed Health⌕ Search

Biomedical subjects

Y Assadi

Publications and source records attributed to Y Assadi.

2 recordsLinked to original sources

Determination of organophosphorus pesticides in water samples by single drop microextraction and gas chromatography-flame photometric detector.

In this paper we have developed single drop microextraction (SDME) with modified 1.00 microl microsyringe, followed by gas chromatography with flame photometric detector (GC-FPD) for determination of 13 organophosphorus pesticides (OPPs) in water samples. By using a 1.00 microl microsyringe the repeatability of drop volume and injection were improved, because of using maximum volume of microsyringe and no dead volume. On the other hand, the modification of needle tip caused increasing cross section of needle tip and increasing adhesion force between needle tip and drop, thereby increasing drop stability and achieving a higher stirrer speed (up to 1700 rpm). The method used 0.9 microl of carbon tetrachloride as extractant solvent, 40 min extraction time, stirring at 1300 rpm and no salt addition. The enrichment factor of this method ranged from 540 to 830. The linear ranges were 0.01-100 microg/l (four orders of magnitude) and limits of detection were 0.001-0.005 microg/l for most of analyte. The relative standard deviation (RSD%) for 2 microg/l of OPPs in water by using internal standard was in the range 1.1-8.6% (n = 5). The recoveries of OPPs from farm water at spiking level of 1.0 microg/l were 91-104%.

Chemical Fractionation↗

Anodized aluminum wire as a solid-phase microextraction fiber.

The efficiency of anodized aluminum wire was investigated as a new fiber for solid-phase microextraction (SPME). Aluminum wires were anodized by direct current in a solution of sulfuric acid at room temperature and were conditioned at 300 degrees C for 30 min. These fibers were used for the extraction of some aliphatic alcohols, BTEX, and petroleum products from gaseous samples. The extracted analytes were transferred to a GC injector using an (inhouse-designed) SPME syringe that also allowed for an easy change of SPME fibers. The results obtained prove the ability of anodized aluminum wire as a new fiber for sampling of organic compounds from gaseous samples. This behavior is due most probably to the porous layer of aluminum oxide, which is formed on the metal surfaces. In this work, the optimum conditions for the preparation and conditioning of fibers and the extraction of analytes from gaseous samples were obtained. In the optimum conditions, one fiber was used in several equal analyses and the relative standard deviations were below 5% (n = 5). However, fiber-to-fiber reproducibility was 8% (n = 5). This fiber is firm, inexpensive, and durable and can be prepared simply.

Journal Article↗