Biplane transesophageal echocardiography: an anatomic-ultrasonic-clinical correlative study.

In 427 subjects TEE was performed with either a uniplane or biplane transducer; in seven cadavers the cardiac anatomic segments were observed in several levels and directions. Nine transverse and six longitudinal views were compared with the corresponding cardiac anatomic segments. Based on this correlative study, the levels of segments, insertion depth, anatomic structure identification, image characteristics, clinical applications, and the advantages as well as the limitations of biplane TEE are discussed.

Adolescent↗

The relationship between intracardiovascular smoke-like echo and erythrocyte rouleaux formation.

Intravascular smoke-like echo always appears in regions of stasis, but the exact mechanism of its production is unclear. We investigated its appearance in relation to erythrocyte rouleaux formation. To study this relationship we performed a series of in vitro and animal experiments. In the in vitro study, we observed an erythrocyte suspension by ultrasonography and found it to be echo-free. Under the microscope, red blood cells were observed in a dispersed state. If an equal amount of lymphocyte separation solution was added to the suspension, smoke-like echo appeared, and red blood cells were seen in a rouleaux pattern. In animal (mongrel dogs) experiments, under physiologic conditions with normal blood flow velocity, all cardiac cavities and the inferior vena cava were echo-free. When stasis was induced experimentally in the inferior vena cava, red blood cells aggregated to form rouleaux and smoke-like echo appeared. On resumption of normal blood flow, the rouleaux dispersed to form erythrocytes again. The mechanism of production of intracardiovascular smoke-like echo is closely related to the formation of erythrocyte rouleaux. When rouleaux are formed, they become larger and appear nearer or larger than the ultrasonic wavelength. Thus reflections are produced and smoke-like echo appears.

Animals↗

[Measurement of gastric emptying in non-ulcer dyspepsia].

Using real-time ultrasonography, we monitored gastric emptying indirectly in 26 cases of non-ulcer dyspepsia (NUD) and 13 healthy adults by determining the anteroposterior gastric measurement of a single section of the stomach in the corpus fundus immediately after drinking 500 ml water and then every 10 min. for five times. The average time for 50% gastric emptying in NUD patients (36.46 +/- 13.13, x +/- s) was longer than that in healthy adults (23.54 +/- 5.93), but the half time of gastric emptying in male with NUD was not significantly different as compared with that in male controls and female patients of NUD.

Adult↗

Biplane transesophageal echocardiography: imaging sections and anatomic segments.

In order to recognize correctly the images of transesophageal echocardiography (TEE), in 410 subjects TEE was performed with uniplane or biplane transducer, and in 7 corpses the cardiac anatomic segments were observed, at various levels and in different directions, 9 transverse and 6 longitudinal views were compared with the corresponding cardiac anatomic segments. Based on this study, the authors reported the levels of segments, insertion depth, anatomic structure identification, image characteristics and clinical application of TEE, and the advantages of biplane TEE are discussed.

Adolescent↗

Follow-up in mitral valve prolapse by phonocardiography, M-mode and two-dimensional echocardiography and Doppler echocardiography.

To assess the serial phonocardiographic and echocardiographic change in patients with mitral valve prolapse (MVP), phonocardiograms and echocardiograms were reviewed retrospectively in 116 patients (48 men and 68 women, mean age 27 years) who had been determined to have MVP and were reexamined 4.3 years (range 1 to 14) later by phonocardiography and echocardiography between 1971 and 1988. Follow-up phonocardiograms showed periods when 5 of 18 patients with silent MVP developed mid- or late systolic clicks. Of 57 patients with mid- or late systolic clicks, 15 had silent MVP, 6 developed a late systolic murmur with or without systolic clicks and 1 developed a pansystolic murmur. Two of 9 patients with an isolated late systolic murmur developed a pansystolic murmur. M-mode echocardiograms showed that left atrial and left ventricular dimensions at end-diastole and end-systole increased in patients with systolic murmur (33 +/- 10 vs 35 +/- 11, 46 +/- 6 vs 50 +/- 7 and 29 +/- 4 vs 31 +/- 5 mm, respectively, all p less than 0.001) and no statistically significant changes in any of these dimensions were found in patients without a systolic murmur. The degree of MVP evaluated by the anteroposterior mitral leaflet angle on the 2-dimensional echocardiogram was more severe in patients with a systolic murmur than in patients without systolic murmur (157 +/- 12 vs 131 +/- 16 degrees, p less than 0.001). The degree of prolapse did not change during the follow-up periods. The number of patients with mitral regurgitation detected by pulsed Doppler echocardiography increased from 21 of 72 (29%) to 31 of 72 (43%).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Application of two-dimensional echocardiography in location of balloon of the Swan-Ganz catheter.

Two-dimensional echocardiography was used to guide and locate the balloon of Swan-Ganz catheter during catheterization in 43 patients. The echoes of balloon appeared as a series of strong light spots, with a rate of detection of 100%. Under monitoring of two-dimensional echocardiography, the site of balloon and its moving route could be determined. The coincidence of echographic findings and X-ray findings showed that it can be used instead of X-ray monitoring to lessen irradiation during catheterization. The depth of catheter inserted was measured. The differential points between the echoes of balloon and tubing, the terminology of the balloon site in echocardiography and fluoroscopy, its clinical value and limitation are discussed.

Adolescent↗

Pulmonary venous flow evaluated by Doppler echocardiography.

In this paper, we report the results of experimental and clinical studies of the pulmonary vein with Doppler echocardiography in 188 cardiac patients and normal controls. 1. The diameter of the right superior pulmonary vein (RSPV): The diameter of the RSPV was 9.8 +/- 0.2 mm in normals and significantly dilated in the groups with passive or active pulmonary hypervolemia and decreased in the group with pulmonary hypovolemia (p less than 0.001). 2. Blood flow velocity of RSPV: The blood flow velocity of the RSPV measured in normal controls by Doppler echocardiography was 35.7 +/- 3.2 cm/s and significantly decreased in the groups with passive pulmonary hypervolemia and pulmonary hypovolemia (19.6 +/- 7.8 cm/s and 25.2 +/- 9.4 cm/s, respectively) and increased in the group with active pulmonary hypervolemia (49.6 +/- 19 cm/s, p less than 0.001). 3. Blood flow of RSPV: Blood flow of the RSPV was 2.3 +/- 1.5 L/m in normals, 3.4 +/- 2.4 L/m in the group with passive pulmonary hypervolemia, 6.2 +/- 2.9 L/m in the group with active pulmonary hypervolemia and 0.7 +/- 0.5 L/m in the group with pulmonary hypovolemia. Blood flow in the active pulmonary hypervolemic group was higher than that in the passive pulmonary hypervolemic group and the hypovolemic group. There was a high correlation between the pulmonary blood flow measured by Fick's method (Qp) and RSPV flow (RSPVF) measured by echocardiography (Qp = 1.96, RSPVF 0.92, r = 0.81, p less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗