PubMed Health⌕ Search

Biomedical subjects

Y B Shim

Publications and source records attributed to Y B Shim.

2 recordsLinked to original sources

Direct DNA hybridization detection based on the oligonucleotide-functionalized conductive polymer.

Electrochemical methods for DNA hybridization detection have many advantages that are very fast to detect hybridization and can be directly applied for a portable DNA sensor. In this paper, an electrochemical method to directly detect DNA hybridization was developed on the basis of a new conductive polymer, which was polymerized on the glassy carbon electrode with a terthiophene monomer having a carboxyl group (3'-carboxyl-5,2',5',2"-terthiophene). The ss-DNA probe was made by chemically bonding an amine-linked C6 alkyl group to the 5' terminus of oligonucleotide (19-mer). The probe moiety was immobilized on the polymer through covalent bonding with a catalyst, 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide. A difference in admittance was observed before and after hybridization as a result of the reduction of the resistance after hybridization. The highest difference in admittance was observed around 1 kHz before and after hybridization. Hybridization amounts of end two-base and center one-base mismatched sequences were obtained only in a 14.3% response when compared to that for the complementary matched sequence.

Base Pair Mismatch↗

Analysis of some metabolites of organic solvents in urine by high-performance liquid chromatography with beta-cyclodextrin.

Chromatographic separation of the metabolites derived from toluene, ethylbenzene, styrene and xylene was carried out on untreated urine samples from factory workers. The elution sequence was as follows: phenylglyoxilic acid, 3-hydroxy-2-butanone, hippuric acid, o-methylhippuric acid, p-methylhippuric acid, m-methylhippuric acid, p-cresol, m-cresol and o-cresol. The stability constants (K(G)) of cresol and methylhippuric acid derivatives were evaluated. The capacity factor (k'), selectivity factor (alpha) and resolution (Rs) are described with a variety of mobile phases containing beta-cyclodextrin (beta-CD). The optimum concentration ratio of ethanol-water-acetic acid-beta-CD was determined to be 20:80:0.3:1.4%. Under these conditions, k' values of the five metabolites were 2<k'<6, and all alpha values were greater than 1.5. Simultaneous determinations of the metabolites were carried out in real urine samples from factory workers using the standard addition method. Validation of the method and the detection limit are described under the optimum conditions attained in this experiment.

Air Pollutants, Occupational↗