Purification and properties of a bacteriolytic enzyme from a soil amoeba Hartmannella glebae.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Y C Chung.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Singular value decomposition (SVD) encoding offers great promise to provide high spatial and temporal resolution required for interventional MRI (I-MRI) (1). This study investigates its efficacy when (a) objects are rotated and (b) a small device (ie, a needle) is moved within anatomic structures. It was found that SVD-encoded MRI is biased toward the reference from which encoding vectors are derived, thus providing a potential limitation under conditions in which the object has undergone significant global change. Reference images with partial device insertion may be needed to accurately resolve the device or track the object motion. Theoretically, the differences between the reference and the object being imaged suggest that SVD encoding is suboptimal (in a minimum mean squared error sense). Other encoding/reconstruction algorithms may come closer to achieving the desired advantages in spatial and temporal fidelity.
This clinical trial was performed to evaluate the safety and feasibility of interactive MR-guided radiofrequency (RF) interstitial thermal ablation (ITA) performed entirely within the MR imager. RF-ITA was performed on 11 intra-abdominal metastatic tumors during 13 sessions. The RF electrode was placed under MR guidance on a .2-T system using rapid fast imaging with steady state precession (FISP) and true FISP images. A custom 17-gauge electrode was used and was modified in four sessions to allow circulation of iced saline for cooling during ablation. Tissue necrosis monitoring and electrode repositioning were based on rapid T2-weighted and short-inversion-time inversion recovery (STIR) sequences. Morbidity and toxicity were assessed by clinical and imaging criteria. The region of tissue destruction was visible in all 11 tumors treated, as confirmed on subsequent contrast-enhanced images. No significant morbidity was noted, and patient discomfort was minimal. In conclusion, interactive MR-guided RF-ITA is feasible on a clinical .2-T C-arm system with supplemental interventional accessories with only minor patient morbidity. The ability to completely ablate tumors with RF-ITA depends on tumor size and vascularity.
The purpose of this study was to determine the suitability of MRI to accurately detect radiofrequency (RF) thermoablative lesions created under MR guidance. In vivo RF lesions were created in the livers of six New Zealand White rabbits using a 2-mm-diameter titanium alloy RF electrode with a 20-mm exposed tip and a 50-W RF generator. This was performed using a 0.2T clinical C-arm MR imager for guidance and monitoring. Each animal was sacrificed and gross evaluation was performed. Histologic correlation was performed on the first two animals. The MR-compatible RF electrode was easily identified on rapid gradient-echo images used to guide electrode placement. A single lesion was created in each rabbit liver. Lesions ranged from approximately 10 to 17 mm in diameter (mean, 13.5 mm). T2-weighted and short T1 inversion recovery (STIR) images demonstrated lesions ranging in diameter from 12 to 18 mm (mean, 14.6 mm). Lesion dimensions determined from images closely correlated with those determined at gross examination with the discrepancy never exceeding 2 mm, for an r2 value of .87. MRI performed at the time of MR-guided RF ablation accurately demonstrated created lesions. This modality may provide a new option for the treatment of local and regional neoplastic disease.
The present paper is a study of theoretic modeling and experimental tests of that modeling for the local heating due to radiofrequency thermal ablation. A model is developed for the current and the associated electric field produced by a radiofrequency ablation probe. The temperature distributions resulting from the induced ohmic currents in the surrounding material are considered. A comparison is made between the theoretic temperature profiles and the shapes of thermal ablation 'lesions' produced in a controlled gelatin sample experiment. Comparison with the contours of human thermally induced liver lesions found in MRI studies also provides a validation of the success of the modeling. Successful modeling should lead to methods for optimization of the ablation procedure, especially as it is used in interventional MRI.
Radiofrequency (RF) energy has many advantages in thermal tumor ablation protocols. With the recent development of open MRI systems, interventional MRI procedures, including thermal ablation, have become the focus of great research interest. However, the significant interference between RF generators and MR imagers has prevented simultaneous imaging and RF ablation and, until now, has limited the role of RF-based thermal therapy in interventional MRI. Here, a simple switching circuit designed with consideration of patient safety provides compatibility between open MRI systems and RF thermal lesion generators. The experimental results show that the switching circuit allows imaging during RF ablation and opens new opportunity for MR-guided thermal therapy.
A heterotrophic Pseudomonas putida CH11 was isolated from livestock farming wastewater and applied for the treatment of H2S-containing gas. Extensive tests including removal characteristics, metabolic products, and removal efficiencies of H2S by P. putida CH11 were examined in batch and continuous systems. The optimum pH required to remove hydrogen sulfide was found in the range of 6-8. The maximum removal rate and the saturation constant were calculated to be Vm = 1.36 g S/day.kg dry bead and Ks = 45.9 ppm, respectively. The main metabolic product of H2S oxidation was determined to be elemental sulfur. When P. putida CH11 was immobilized within Ca alginate, the cells exhibited high H2S removal efficiency, in excess of 96%, at concentration of hydrogen sulfide from 10 to 150 ppm (flow rates of 36 and 72 L/h). These results suggest that P. putida CH11 immobilized within Ca alginate has the potential to be used as a H2S removal agent.
A heterotrophic Arthrobacter oxydans CH8 that was capable of removing NH3 from NH3 containing gas was isolated from livestock farming wastewater. The A. oxydans CH8 was immobilized with calcium alginate packed into filter column. Metered NH3-containing gas was partially humidified and passed through the glass column. Extensive tests including the removal characteristics, the removal efficiencies, and the metabolic products of NH3 by A. oxydans CH8 were conducted. Additionally, the operation criteria for the biofilter was also established. NH3 removel capacities were elevated by the immobilized-cell (biological conversion) method and the BDST (bed depth service time) method (physical adsorption), respectively. The optium temperature for removing NH3 was 30 degrees C, while the nitrification ability remained 80% at 40 degrees C. The high efficiency (> 97%) in the removal of NH3 was attained at 36 L/h with pH control and was not decreased because of high NH3 inlet concentration. In addition, the high maximum removal rate (1.22 g of N/day (kg of bead)) enhanced the use of the biofilter in industrial-scale NH3(g) pollution control. The ability to remove NH3 at high inlet concentration and temperature suggested that the immobilized A. oxydans CH8 biofilter has potential in processing NH3 gas.