PubMed Health⌕ Search

Biomedical subjects

Y De Wilde

Publications and source records attributed to Y De Wilde.

4 recordsLinked to original sources

Analysis of the measured signals in apertureless near-field optical microscopy.

We present an analytical model able to explain the optical signal recorded during our experimental approach curves in the infrared at a wavelength lambda=10.6 microm, with a home-made apertureless near-field scanning optical microscope ANSOM. This model uses classical electrodynamics to calculate the scattering cross section of the oscillating tip, considered as a dipole, and its dielectric image in the sample as a function of the tip-sample separation from the near-field to the far-field regime. The dipoles are placed in a non-uniform electric field because of the standing wave arising from the interference between the incident and the specular laser beams. We also added a background field coming from a scatterer on the surface in order to account for zeroing of the optical signal for particular tip-sample separation and interference patterns.

Journal Article↗

Apertureless scanning near-field fluorescence microscopy in liquids.

We show that apertureless scanning near-field optical microscopes that use sharp vibrating conical tips can be operated in liquid environments. We have investigated the damping of the tip oscillation as a function of its shape and as a function of its depth under the liquid surface. The degradation of the quality factor from 150 in air down to 15 in liquid does not impede to perform topographic and optical measurements with a very good sensitivity. As an example of application, we present near-field fluorescence images of dye-doped polystyrene spheres immersed in a liquid.

Microscopy, Fluorescence↗

Upconversion fluorescence imaging of erbium-doped fluoride glass particles by apertureless SNOM.

We have imaged fluorescent erbium-doped fluoride glass particles by apertureless scanning near-field optical microscopy. The optical excitation has been performed at lambda = 780 nm whereas fluorescence emission has been collected around lambda = 550 nm. This process, called upconversion by energy transfer, involves two erbium ions and is not linear. Besides an improvement of the lateral resolution, we have observed on some particles that the fluorescence is not homogeneously distributed, but is rather localized in some zones brighter than others. By making tip approach curves, we have also observed that the amount of fluorescence intensity scattered by the tip is increasing when the tip is approaching the sample surface.

Journal Article↗

Apertureless near-field scanning optical microscope working with or without laser source.

An apertureless near-field scanning optical microscope (ANSOM), used indifferent configurations, is presented. Our versatile home-made setup, based on a sharp tungsten tip glued onto a quartz tuning fork and working in tapping mode, allows to perform imaging over a broad spectral range. We have recorded optical images in the visible (wavelength, lambda = 655 nm) and in the infrared (lambda = 10.6 microm), proving that the setup routinely achieves an optical resolution of <50 nm regardless of the illumination wavelength. We have also shown optical images recorded in the visible (lambda = 655 nm) in an inverted configuration where the tip does not perturb the focused spot of the illumination laser. Approach curves as well as image profiles have revealed that on demodulating the optical signal at higher harmonics, we can obtain an effective probe sharpening which results in an improvement of the resolution. Finally, we have presented optical images recorded in the infrared without any illumination, that is, the usual laser source is replaced by a simple heating of the sample. This has shown that the ANSOM can be used as a near-field thermal optical microscope (NTOM) to probe the near field generated by the thermal emission of the sample.

Journal Article↗