PubMed Health⌕ Search

Biomedical subjects

Y E Erdi

Publications and source records attributed to Y E Erdi.

11 recordsLinked to original sources

FDG-PET standardized uptake values in normal anatomical structures using iterative reconstruction segmented attenuation correction and filtered back-projection.

Filtered back-projection (FBP) is the most commonly used reconstruction method for PET images, which are usually noisy. The iterative reconstruction segmented attenuation correction (IRSAC) algorithm improves image quality without reducing image resolution. The standardized uptake value (SUV) is the most clinically utilized quantitative parameter of [fluorine-18]fluoro-2-deoxy-D-glucose (FDG) accumulation. The objective of this study was to obtain a table of SUVs for several normal anatomical structures from both routinely used FBP and IRSAC reconstructed images and to compare the data obtained with both methods. Twenty whole-body PET scans performed in consecutive patients with proven or suspected non-small cell lung cancer were retrospectively analyzed. Images were processed using both IRSAC and FBP algorithms. Nonquantitative or gaussian filters were used to smooth the transmission scan when using FBP or IRSAC algorithms, respectively. A phantom study was performed to evaluate the effect of different filters on SUV. Maximum and average SUVs (SUVmax and SUVavg) were calculated in 28 normal anatomical structures and in one pathological site. The phantom study showed that the use of a nonquantitative smoothing filter in the transmission scan results in a less accurate quantification and in a 20% underestimation of the actual measurement. Most anatomical structures were identified in all patients using the IRSAC images. On average, SUVavg and SUVmax measured on IRSAC images using a gaussian filter in the transmission scan were respectively 20% and 8% higher than the SUVs calculated from conventional FBP images. Scatterplots of the data values showed an overall strong relationship between IRSAC and FBP SUVs. Individual scatterplots of each site demonstrated a weaker relationship for lower SUVs and for SUVmax than for higher SUVs and SUVavg. A set of reference values was obtained for SUVmax and SUVavg of normal anatomical structures, calculated with both IRSAC and FBP image reconstruction algorithms. The use of IRSAC and a gaussian filter for the transmission scan seems to give more accurate SUVs than are obtained from conventional FBP images using a nonquantitative filter for the transmission scan.

Aged↗

Use of PET to monitor the response of lung cancer to radiation treatment.

Approximately 170,000 people are diagnosed with lung cancer in the United States each year. Many of these patients receive external beam radiation for treatment. Fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography (FDG PET) is increasingly being used in evaluating non-small cell lung cancer and may be of clinical utility in assessing response to treatment. In this report, we present FDG PET images and data from two patients who were followed with a total of eight and seven serial FDG PET scans, respectively, through the entire course of their radiation therapy. Changes in several potential response parameters are shown versus time, including lesion volume (V(FDG)) by PET, SUVav, SUVmax, and total lesion glycolysis (TLG) during the course of radiotherapy. The response parameters for patient 1 demonstrated a progressive decrease; however, the response parameters for patient 2 showed an initial decrease followed by an increase. The data presented here may suggest that the outcome of radiation therapy can be predicted by PET imaging, but this observation requires a study of additional patients.

Aged↗

Pharmacokinetics and dosimetry of an alpha-particle emitter labeled antibody: 213Bi-HuM195 (anti-CD33) in patients with leukemia.

UNLABELLED: Data from nine patients with leukemia participating in a phase I activity-escalation study of HuM195, labeled with the alpha-particle emitter 213Bi (half-life = 45.6 min), were used to estimate pharmacokinetics and dosimetry. This is the first trial using an alpha-particle emitter in humans. The linear energy transfer of alpha particles is several hundredfold greater than that of beta emissions. The range in tissue is approximately 60-90 microm. METHODS: The activity administered to patients ranged from 0.6 to 1.6 GBq. Patient imaging was initiated at the start of each injection. Thirty 1-min images followed by ten 3-min images were collected in dynamic mode; a 20% photopeak window centered at 440 keV was used. Blood samples were collected until 3 h postinjection and counted in a gamma counter. Contours around the liver and spleen were drawn on the anterior and posterior views and around a portion of the spine on the posterior views. No other organs were visualized. RESULTS: The percentage injected dose in the liver and spleen volumes increased rapidly over the first 10-15 min to a constant value for the remaining hour of imaging, yielding a very rapid uptake followed by a plateau in the antibody uptake curves. The kinetic curves were integrated to yield cumulated activity. The mean energy emitted per nuclear transition for 213Bi and its daughters, adjusted by a relative biologic effectiveness of 5 for alpha emissions, was multiplied by the cumulated activity to yield the absorbed dose equivalent. Photon dose to the total body was determined by calculating a photon-absorbed fraction. The absorbed dose equivalent to liver and spleen volumes ranged from 2.4 to 11.2 and 2.9 to 21.9 Sv, respectively. Marrow (or leukemia) mean dose ranged from 6.6 to 12.2 Sv. The total-body dose (photons only) ranged from 2.2 x 10(-4) to 5.8 x 10(-4) Gy. CONCLUSION: This study shows that patient imaging of 213Bi, an alpha-particle emitter, labeled to HuM195 is possible and may be used to derive pharmacokinetics and dosimetry. The absorbed dose ratio between marrow, liver and spleen volumes and the whole body for 213Bi-HuM195 is 1000-fold greater than that commonly observed with beta-emitting radionuclides used for radioimmunotherapy.

Acute Disease↗

Use of the fast Hartley transform for three-dimensional dose calculation in radionuclide therapy.

Effective radioimmunotherapy may depend on a priori knowledge of the radiation absorbed dose distribution obtained by trace imaging activities administered to a patient before treatment. A new, fast, and effective treatment planning approach is developed to deal with a heterogeneous activity distribution. Calculation of the three-dimensional absorbed dose distribution requires convolution of a cumulated activity distribution matrix with a point-source kernel; both are represented by large matrices (64 x 64 x 64). To reduce the computation time required for these calculations, an implementation of convolution using three-dimensional (3-D) fast Hartley transform (FHT) is realized. Using the 3-D FHT convolution, absorbed dose calculation time was reduced over 1000 times. With this system, fast and accurate absorbed dose calculations are possible in radioimmunotherapy. This approach was validated in simple geometries and then was used to calculate the absorbed dose distribution for a patient's tumor and a bone marrow sample.

Antibodies, Monoclonal↗

Segmentation of lung lesion volume by adaptive positron emission tomography image thresholding.

BACKGROUND: It is common protocol in radionuclide therapies to administer a tracer dose of a radiopharmaceutical, determine its lesion uptake and biodistribution by gamma imaging, and then use this information to determine the most effective therapeutic dose. This treatment planning approach can be used to quantitate accurately the activity and volume of lesions and organs with positron emission tomography (PET). In this article, the authors focus on the specification of appropriate volumes of interest (VoI) using PET in association with computed tomography (CT). METHODS: The authors have developed an automatic image segmentation schema to determine the VoI of metastases to the lung from PET images, under conditions of variable background activity. An elliptical Jaszczak phantom containing a set of spheres with volumes ranging from 0.4 to 5.5 mL was filled with F-18 activity (2-3 microCi/mL) corresponding to activities clinically observed in lung lesions. Images were acquired with a cold background and then with variable source-to-background (S/B) ratios of: 7.4, 5.5, 3.1, and 2.8. Lesion VoI analysis was performed on 10 patients with 17 primary or metastatic lung lesions, applying the optimum threshold values derived from the phantom experiments. Initial volume estimates for lung lesions were determined from CT images. Approximate S/B ratios were obtained for the corresponding lesions on F-18-fluoro-2-deoxy-D-glucose (18FDG)-PET images. From the CT estimate of the lesion size and the PET estimate of the S/B ratio, the appropriate optimum threshold could be chosen. The threshold was applied to the PET images to obtain lesion activity and a final estimate of the lesion volume. RESULTS: Phantom data analysis showed that image segmentation converged to a fixed threshold value (from 36% to 44%) for sphere volumes larger than 4 mL, with the exact value depending on the S/B ratios. For patients, the use of optimum threshold schema demonstrated a good correlation (r = 0.999) between the initial volume from CT and the final volume derived from the 18FDG-PET scan (P < 0.02). The mean difference for those volumes was 8.4%. CONCLUSIONS: The adaptive thresholding method applied to PET scans enables the definition of tumor VoI, which hopefully leads to accurate tumor dosimetry. This method can also be applied to small lesions (<4 mL). It should enable physicians to track objectively changes in disease status that could otherwise be obscured by the uncertainties in the region-of-interest drawing, even when the scans are delineated by the same physician.

Aged↗

Quantitative bone metastases analysis based on image segmentation.

UNLABELLED: Preliminary evidence indicates that the fraction of bone containing metastatic lesions is a strong prognostic indicator of survival longevity for prostate and breast cancer. Our current approach to quantify metastatic bone lesions, called the Bone Scan Index, is based on an inspection of the bone scan, estimating visually the fraction of each bone involved and then summing across all bones to determine the percentage of total skeletal involvement. This approach, however, is time consuming, subjective and dependent on individual interpretation. METHODS: To overcome these problems, a semiautomated image segmentation program was developed for the quantitation of metastases from planar whole-body bone scans. The user is required to insert a seed point into each metastatic region on the image. The algorithm then connects pixels to the seed pixel in all directions until a contrast-dependent threshold is reached. The optimal threshold for cessation of the region growing is determined from phantom studies. On the images, lesion delineation and size measurements were performed by the algorithm. Each delineated lesion is associated with a bone site using pull-down menus. The program then computes the fraction of lesion involvement in each bone based on look-up-tables containing the relationship of bone mass with race, sex, height and age. These look-up-tables were obtained by multiple regression of the skeletal mass measurements in humans. The total fraction of skeletal involvement is then obtained from the individual fractional masses. For individual fractional mass, values given in International Commission on Radiation Protection Publication No. 23 were used. RESULTS: The bone metastases analysis system has been used on 11 scans from 6 patients. The correlation was high (r = 0.83) between conventional (manually drawn region-of-interest) and this analysis system. Bone metastases analysis results in consistently lower estimates of fractional involvement in bone compared with the conventional region-of-interest drawing or visual estimation method. This is due to the apparent broadening of objects at and below the limits of resolution of the gamma camera. CONCLUSION: Image segmentation reduces the delineation and quantitation time of lesions by at least two compared with manual region-of-interest drawing. The objectivity of this technique allows the detection of small variations in follow-up patient scans for which the manual region-of-interest method may fail, due to performance variability of the user. This method preserves the diagnostic skills of the nuclear medicine physician to select which bony structures contain lesions, yet combines it with an objective delineation of the lesion.

Adolescent↗

Treatment planning for radio-immunotherapy.

To foster the success of clinical trials in radio-immunotherapy (RIT), one needs to determine (i) the quantity and spatial distribution of the administered radionuclide carrier in the patient over time, (ii) the absorbed dose in the tumour sites and critical organs based on this distribution and (iii) the volume of tumour mass(es) and normal organs from computerized tomography or magnetic resonance imaging and appropriately correlated with nuclear medicine imaging techniques (such as planar, single-photon emission computerized tomography or positron-emission tomography). Treatment planning for RIT has become an important tool in predicting the relative benefit of therapy based on individualized dosimetry as derived from diagnostic, pre-therapy administration of the radiolabelled antibody. This allows the investigator to pre-select those patients who have 'favorable' dosimetry characteristics (high time-averaged target: non-target ratios) so that the chances for treatment success may be more accurately quantified before placing the patient at risk for treatment-related organ toxicities. The future prospects for RIT treatment planning may yield a more accurate correlation of response and critical organ toxicity with computed absorbed dose, and the compilation of dose-volume histogram information for tumour(s) and normal organ(s) such that computing tumour control probabilities and normal tissue complication probabilities becomes possible for heterogeneous distributions of the radiolabelled antibody. Additionally, radiobiological consequences of depositing absorbed doses from exponentially decaying sources must be factored into the interpretation when trying to compute the effects of standard external beam isodose display patterns combined with those associated with RIT.

Beta Particles↗

Threshold estimation in single photon emission computed tomography and planar imaging for clinical radioimmunotherapy.

Thresholding is the most widely used organ or tumor segmentation technique used in single photon emission computed tomography (SPECT) and planar imaging for monoclonal antibodies. Selecting the optimal threshold requires a priori knowledge (volumes from CT or magnetic resonance) for the size and contrast level of the organ in question. Failure to select an optimal threshold leads to overestimation or underestimation of the volume and, subsequently, the organ-absorbed dose value in radio-immunotherapy. To investigate this threshold selection problem, we performed a phantom experiment using six lucite spheres ranging from 1 to 117 ml and filled with a uniform activity of 1 microCi/ml Tc-99m. These spheres were placed at the center and off-center locations of a Jasczsak phantom and scanned with a three-headed gamma camera in SPECT and planar modes. Target-nontarget (T:NT) ratios were changed by adding the appropriate activity to the background. A threshold search algorithm with an interpolative background correction was applied to sphere images. This algorithm selects a threshold that minimizes the difference between the true and measured volumes (SPECT) or areas (planar). It was found that for spheres equal to or larger than 20 ml [diameter (D) > 38 mm] and T:NT ratios higher than 5:1, mean thresholds at 42% for SPECT and 38% for planar imaging yielded minimum image segmentation errors, which is in agreement with current literature. However, for small T:NT ratios (< 5:1), the threshold values as high as 71% for SPECT and 85% for planar imaging were substantially different than those fixed thresholds for large spheres (D > 38 mm). Hence, the use of fixed thresholds in low contrasts and with tumor and organ sizes of clinical interest (25 < or = D < or = 50 mm) may result in limited volume estimation accuracy. Therefore, we have provided the investigator a method to obtain the threshold values in which the proper threshold can be selected based on the organ and tumor size and image contrast. By measuring and calibrating the proper threshold value derived through machine-specific phantom measurements, a more accurate volume and activity quantitation can be performed. This, in turn, will provide tumor-absorbed dose optimization and greater accuracy in the measurement of potentially subacute, toxic absorbed doses to normal organs for patients undergoing radioimmunotherapy.

Algorithms↗

A new fiducial alignment system to overlay abdominal computed tomography or magnetic resonance anatomical images with radiolabeled antibody single-photon emission computed tomographic scans.

BACKGROUND: The use of computed tomography (CT) or magnetic resonance (MR) to overlay or register uptake patterns displayed by single-photon emission computed tomography (SPECT) with specific underlying anatomy has the potential to improve image interpretation and decrease diagnostic reading errors. The authors have developed a method that will allow the selection of a region of interest on MR or CT images that correlates with SPECT antibody images from the same patient. This method was validated first in phantom studies and subsequently was used on three patients with suspected colorectal carcinoma. METHODS: Two patients were injected with the technetium-99m-labeled 88BV59 immunoglobulin G human antibody, and the third patient was injected with the iodine-131-labeled 16.88 immunoglobulin M human antibody. CT or MR scans were obtained before antibody infusion, and subsequent SPECT scans were obtained on the first or fourth day after infusion. A customized body cast with landmarks was used for each patient during the CT, MR, and SPECT scans to match slice positions for all scanning modalities. Corresponding fiducial landmarks were identified on axial images. A computer graphics program was written to match and overlay corresponding landmarks for each imaging modality. The image registration accuracy was measured by comparing fiducial marker separations (center to center) on the registered scans. This separation uncertainty was 1-2 mm for CT-MR and 3-4 mm for CT-SPECT phantom studies. RESULTS: For patient studies, the fiducial alignment uncertainty was 3-4 mm for axial CT-SPECT and MR-SPECT images, and 6-8 mm for sagittal CT-SPECT and MR-SPECT images. The accuracy of the anatomic alignment of the patient and image registration system was +/- 1 cm in the medial-lateral axis and +/- 2 cm in the cranial-caudal direction. CONCLUSIONS: This type of image analysis may resolve uncertainties with the anatomic correlation of SPECT images that otherwise may be regarded as questionable when SPECT is used alone for radioimmunodiagnosis.

Colorectal Neoplasms↗

Tumor activity confirmation and isodose curve display for patients receiving iodine-131-labeled 16.88 human monoclonal antibody.

A study was performed to correlate activity quantitation derived from external imaging with surgical tumor specimens in patients who received radiolabeled monoclonal antibody. Patients were given I-131 labeled 16.88 human antibody and scanned 3-5 times by planar and/or single photon emission computed tomography imaging methods to acquire time-dependent activity data in tumor and normal tissues. A method also was developed to assess the heterogeneous activity distributions in tumor samples. Postsurgical tumor and normal tissue samples were subdivided into volume elements (voxels) of 0.5 cm x 0.5 cm x 0.05 cm thick, which were used to verify the activity quantitation computed by the conjugate view method and to appraise the heterogeneity of radiolabeled antibody uptake. Through the use of the measured voxel activities, along with the time-dependent activity curves available for the entire tumor specimen derived from imaging, the cumulated activity and absorbed dose for each voxel were uniquely determined. The calculated total absorbed dose values were color-coded as isodose curves and overlaid on a correlated computed tomographic image. In two patients, activity quantitation derived from external imaging correlated with surgical tumor resection specimens within +/- 11%. The tumor-absorbed dose heterogeneity ratio was found to be as high as 10:1, with an average tumor to whole body absorbed dose ratio of 4:1. The mapping of activity with a histologic overlay showed a good correlation among activity uptake, the presence of tumor, and antigen expression on a microscopic scale. The resultant isodose curves overlaid on correlative computed tomographic scans represent the first images obtained with actual radiolabeled antibody biodistribution data in patients.

Absorption↗