PubMed Health⌕ Search

Biomedical subjects

Y H Pao

Publications and source records attributed to Y H Pao.

5 recordsLinked to original sources

A neural network approach for the determination of interhospital transport mode.

We report on the construction of neural networks for determining whether pediatric patients requiring transport to a tertiary care center should be moved by air or by ground. The networks were based on the functional-link net architecture. In two experiments, feedforward supervised-learning neural nets were trained with examples of an expert's decisions and then were used in a consulting mode to provide advice on cases not previously encountered. Training and validation were performed by a combination of the k-fold cross-validation and leaving-one-out sampling methods. Use of the functional-link net rather than the customary backpropagation net enabled us to carry out the training with fairly large amounts of data in realistically short time periods. In the first experiment, capillary refill, skin color, and stridor were consistently the input variables that were most strongly associated with the decision output. In both experiments, the networks were validated by comparing their performance retrospectively against the determination of an expert pediatric transport physician. The network was trained based on the expert's opinion about the correct mode of transport for each case with error rates of less than 10(-5).

Artificial Intelligence↗

Multicategory classification of body surface potential maps.

A statistical classification method is suggested for body surface potential maps (BSPM). The initial data reduction utilizes the Fourier expansion and time integration, resulting in physiological-oriented features. Based on Fischer's criterion, optimal discriminant vectors are used to map the features to an optimal subdomain. Experimental criteria determine the dimensionality of the subdomain and the number of features to be mapped into it. Classification is performed in two steps. In the first, a k-nearest neighbor (k-NN) rule is used for every two-category problem, the results of which are fed into a voting rule for final classification. The method is tested with 123 patients divided into four categories: normal (NR), ischemia (IS), myocardial infarction (MI), and left bundle branch block (LB) patients. The success is between 88% (for IS) and 100% (for LB) for QRS segment integration. Departure maps were used to explain the misclassified patterns.

Algorithms↗

Telemedicine in critical care: an experiment in health care delivery.

We hypothesized that telemedicine -- medicine practiced from a distance using telecommunications -- can solve some problems related to the scarcity and maldistribution of specialists in critical care medicine. Using a two-way audiovisual link between a small private hospital and a large university medical center, we have provided daily consultations by an intensivist to patients in the small institution. During the first 175 days of the project we found: 1) regular consultations in critical care can be provided using the audiovisual link; 2) current technology is adequate but expensive; 3) telemedicine consultations can be made acceptable to users and providers; 4) telemedicine can be a valuable educational resource; 5) telemedicine can influence the process and probably the outcome of patient care; 6) the audiovisual link is superior to the telephone for these consultations; and 7) telemedicine can serve as an important link between a small hospital and a large medical center favorably influencing the quality of care in the critical care unit of the small hospital.

Audiovisual Aids↗

Pseudonoise coded ultrasonic holographic imaging.

In this paper, a pseudonoise (PN) coded ultrasonic holographic imaging system design is studied with computer simulation. A system utilizing PN coded phase-modulated ultrasonic signals is capable of yielding both high lateral and high range resolution. It is found that the time for data acquisition and image reconstruction is much less than that required for some comparable methods. The PN coded imaging system also has excellent noise immunity, and this is of great practical importance. Some results for a simulated three-dimensional imaging geometry are shown to demonstrate the characteristics of PN coded ultrasound systems.

Holography↗