Immunohistochemical detection of galectin-3 in canine gastric carcinomas.

Galectin-3 was detected immunohistochemically in nine canine gastric carcinomas. In normal gastric tissue adjacent to the neoplasms, the gastric epithelial cells showed faint immunolabelling for galectin-3, but in all the tumours the neoplastic cells showed moderate to strong immunolabelling. Galectin-3 was localized in the cytoplasm of the normal mucosal cells, whereas it was found in both the cytoplasm and the nucleus of the neoplastic cells. Positive cells typically exhibited dark brown coloration of the nucleus or cytoplasm, without background labelling. The results suggest that galactin-3 has a pathophysiological role in canine gastric carcinoma.

Animals↗

DA-8159, a new PDE5 inhibitor, attenuates the development of compensatory right ventricular hypertrophy in a rat model of pulmonary hypertension.

This study evaluated the effect of DA-8159, a new phosphodiesterase 5 inhibitor, on the compensatory development of right ventricular hypertrophy in monocrotaline (MCT)-induced pulmonary hypertension (PH). Rats treated with subcutaneous MCT were divided into three groups, which received DA-8159 1 mg/kg, DA-8159 5 mg/kg or saline-vehicle orally, twice daily for 21 days. The vehicle group demonstrated increased right ventricular weight, pulmonary artery medial wall thickening, myocardial fibrosis, increased plasma cyclic guanosine monophosphate (cGMP) concentration and reduced body weight gains. DA-8159, however, markedly attenuated the compensatory development of right ventricular hypertrophy and pulmonary artery medial wall thickening, amplified the increase in plasma cGMP levels and increased lung cGMP concentrations. In addition, DA-8159 prevented myocardial fibrosis induced by MCT. These results demonstrate that DA-8159 attenuates the compensatory development of right ventricular hypertrophy in a rate model of PH. DA-8159 might, therefore, be a useful treatment option for PH, but its efficacy in humans needs evaluating.

3',5'-Cyclic-GMP Phosphodiesterases↗

Hemodynamic and humoral conditions in stepwise reduction of pulmonary blood flow during venoarterial bypass in awake goats.

The effects of reduced pulmonary arterial blood flow (PAF) during venoarterial bypass (VAB) on hemodynamic and humoral conditions were investigated in a series of experiments in a chronic animal model. A biventricular bypass system was installed in five adult goats weighing 49.8 +/- 1.1 kg. Two weeks later, the extracorporeal circuitry was changed to VAB without anesthesia. The PAF was reduced stepwise from 100% to 50, 25, 10, and 0% of total systemic flow. The mean aortic pressure and systemic vascular resistance decreased from 110 +/- 14 to 66 +/- 3 mmHg and from 1,288 +/- 77 to 740 +/- 73 dyne.sec/cm5, respectively, in proportion to the decrease in PAF from 100 to 0%. The prostaglandin E2 concentration increased from 1.5 +/- 0.6 to 8.8 +/- 0.6 pg/ml following the decrease in PAF from 100 to 0%. The renin-angiotensin system increased in proportion to the decrease in PAF. In contrast, the epinephrine and norepinephrine concentrations (60 +/- 10 and 227 +/- 80 pg/ml, respectively, at 100% PAF) did not change appreciably even at 10% PAF, but were markedly elevated to 335 +/- 117 and 2,088 +/- 1,503 pg/ml at 0% PAF. The antidiuretic hormone level similarly changed. In conclusion, decrease in PAF during VAB exerts significant effects on hemodynamics in a proportional manner and on vasoactive humoral factors in a diverse manner.

Animals↗

In vitro and in vivo heat dissipation of an electrohydraulic totally implantable artificial heart.

The authors evaluated the heat transfer characteristics of an electrohydraulic totally implantable artificial heart (EH-TAH) developed at our institute. In three in vitro experiments, the heat dissipation of the EH-TAH was investigated. First, the EH-TAH was connected to a closed mock circuit filled with 1 L of saline, and driven at an input power of 20 W. The estimated heat conducted to the blood was approximately 10.3 W, which was almost half of the input power. Second, we simulated heat transfer with the circulation of a calf by using a heat exchanger. The amount of heat dissipating directly from the EH-TAH surface was calculated to be 10 W. Third, the temperature of the actuator examined with thermography was found to be almost uniform, and no prominent high temperature area was observed. In an in vivo study, the EH-TAH was implanted for 10 days in a calf weighing 62 kg. The input power was 18 +/- 2 W, the temperature of the actuator-tissue contacting surface was 39.4 +/- 0.8 degrees C, and that of the pump blood chamber was 39.8 +/- 0.4 degrees C. This slight temperature elevation was thought to be attributable to heat dissipation to the blood. On histologic study of the chest wall and the lung in contact with the actuator, vascularized connective tissue envelopes were observed, but unfavorable side effects, such as tissue necrosis, were not observed. These results suggest that the thermal effect of this system is acceptable at the input power used.

Animals↗

In vitro and in vivo evaluation of a left-right balancing capacity of an interatrial shunt in an electrohydraulic total artificial heart system.

The authors evaluated the basic performance of an interatrial shunt (IAS) made by punching a hole in the atrial septum, in accommodating the left-right imbalance in our electrohydraulic total artificial heart (EHTAH) system. In an in vitro study conducted in a closed mock circuit connected with the EHTAH, the interatrial pressure gradient changed in compliance with the amount of bronchial flow and the size of the IAS. The IAS of 4.4 mm diameter or larger maintained the interatrial pressure gradient within physiologically permissible limits when the amount of bronchial flow was 5% of cardiac output or less. A left-to-right one-way valve made of a piece of pericardium, a possible option in this IAS method, successfully prevented right-to-left reverse shunt flow through the IAS. In a chronic in vivo study using a calf implanted with the EHTAH for 10 days, a 4.5 mm IAS without the one-way valve demonstrated satisfactory dynamic left-right balancing capacity with a stable interatrial pressure gradient of 4 +/- 1 mmHg over a wide range of atrial pressures. No thrombus was found in or around the IAS at autopsy. The authors conclude that the IAS is a simple and promising means of left-right balancing in the EHTAH system.

Animals↗

Morphologic changes of the aortic wall due to reduced systemic pulse pressure in prolonged non pulsatile left heart bypass.

The morphologic changes of the aortic wall due to reduced systemic pulse pressure in prolonged non pulsatile left heart bypass (LHB) were investigated. Sixteen adult goats were divided into three groups: the non pulsatile group in which non pulsatile LHB was conducted for 137 days on average, the pulsatile group in which pulsatile LHB was conducted for 79 days on average, and the control group used as the normal control. The average aortic pulse pressures were 12, 48, and 37 mmHg, respectively. At the end of the experiments, the descending aorta was excised and subjected to morphologic examination. The wall thickness of the aorta in the non pulsatile group (1.4 mm) was significantly thinner than that in the pulsatile group (2.2 mm) and the control group (2.0 mm), and the volume ratio of smooth muscle cells (SMC) in the non pulsatile group (37%) was lower than that in the pulsatile group (48%) and the control group (49%). In SMC classification, the proportion of SMC with low activity and low contractility in the non pulsatile group (57%) was high as compared with that in the pulsatile (2%) and control (5%) groups. These results strongly indicate that prolonged non pulsatile LHB causes substantial morphologic changes in the aorta.

Animals↗